Skip header and navigation

Refine By

66 records – page 1 of 4.

arterial-venous blood tubing set

http://mhc.andornot.com/en/permalink/artifact24
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020024 a-b
Description
Hemodialysis arterial-venous blood tubing set, which consists of two lengths of silastic tubing with plastic attachments; the arterial blood tubing set (a) consists of a cylindrical hollow clear plastic chamber with covered ends, both of which have lengths of silastic tubing coming from them; the t…
  2 images  
Accession Number
998020024 a-b
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Hemodialysis -- instrumentation
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Hemodialysis arterial-venous blood tubing set, which consists of two lengths of silastic tubing
with plastic attachments; the arterial blood tubing set (a) consists of a cylindrical hollow clear
plastic chamber with covered ends, both of which have lengths of silastic tubing coming from them;
the top of the chamber has a long length of silastic tubing and a short length; there are also two
short lengths of tubing leading off from the main tube; all tube ends have attached caps and the
small tube pieces have attached rounded clips which can be clicked closed to pinch the tube closed;
the bottom of the chamber has a long length of silastic tubing with a plastic cap at the end and a
clip on the tube just above the cap; all plastic end pieces are either red or clear in colour; the
clips are all made of white plastic; the venous blood tubing set (b) consists of a cylindrical hollow
clear plastic chamber with covered ends, both of which have lengths of silastic tubing coming
from them; the top of the chamber has a long length of silastic tubing and two short lengths coming
out from it; all tube ends have attached caps and the small tube pieces have attached rounded plastic
clips which can be clicked closed to pinch the tube closed; the bottom of the chamber has a
long length of silastic tubing with an attached cap at the end and a clip on the tube just above
the cap; all plastic end pieces are either blue or white in colour; the clips are all made of white
plastic
Number Of Parts
2
Part Names
a - arterial blood tubing set - Size: Length 409.5 cm. x Diameter2.8 cm.
b - venous blood tubing set - Size: Length 303.3 cm. x Diameter2.2
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Medisystems Corporation
Site Made (Country)
Thailand
Material
plastic: clear; blue; red; white
silastic: clear
Inscriptions
The bag the blood tubing set arrived in has printed information on it which reads, "OPEN // Cat. No
M3-9605/9795 // Lot No 2X12k1 // 1 unit // Arterial-Venous // Blood Tubing Set // For single use
only // Sterile nonpyrogenic fluid path. // Do not use if tip protectors are not in place. // See
directions enclosed in carton prior to use. // CAUTION: Federal (USA) Law restricts this device to
sale by or on order of a physician. // Manufactured for: // Medisystems // CORPORATION // San Francisco,
CA 94104 // Made in Thailand"
Permanent Location
Storage Room 0010
0010-E7-2
Condition Remarks
The tubing set arrived sealed in a plastic bag and has never been used; all parts are complete and undamaged; #2: rubber requires special treatment
Copy Type
Original
Reference Types
Person
Other
JPG
Reference Comments
Dr. Peter Morrin; see also 998.020.025 and .026; CD #10.
Images
Less detail

arterial-venous blood tubing set

http://mhc.andornot.com/en/permalink/artifact25
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020025 a-b
Description
Hemodialysis arterial-venous blood tubing set, which consists of two lengths of silastic tubing with plastic attachments; the arterial blood tubing set (a) consists of a cylindrical hollow clear plastic chamber with covered ends, both of which have lengths of silastic tubing coming from them; the t…
Accession Number
998020025 a-b
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Hemodialysis -- instrumentation
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Hemodialysis arterial-venous blood tubing set, which consists of two lengths of silastic tubing
with plastic attachments; the arterial blood tubing set (a) consists of a cylindrical hollow clear
plastic chamber with covered ends, both of which have lengths of silastic tubing coming from them;
the top of the chamber has a long length of silastic tubing and a short length; there are also two
short lengths of tubing leading off from the main tube; all tube ends have attached caps and the
small tube pieces have attached rounded clips which can be clicked closed to pinch the tube closed;
the bottom of the chamber has a long length of silastic tubing with a plastic cap at the end and a
clip on the tube just above the cap; all plastic end pieces are either red or clear in colour; the
clips are all made of white plastic; the venous blood tubing set (b) consists of a cylindrical hollow
clear plastic chamber with covered ends, both of which have lengths of silastic tubing coming
from them; the top of the chamber has a long length of silastic tubing and two short lengths coming
out from it; all tube ends have attached caps and the small tube pieces have attached rounded plastic
clips which can be clicked closed to pinch the tube closed; the bottom of the chamber has a
long length of silastic tubing with an attached cap at the end and a clip on the tube just above
the cap; all plastic end pieces are either blue or white in colour; the clips are all made of white
plastic
Number Of Parts
2
Part Names
a - arterial blood tubing set - Size: Length 409.5 cm. x Diameter2.8 cm.
b - venous blood tubing set - Size: Length 303.3 cm. x Diameter2.2
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Medisystems Corporation
Site Made (Country)
Thailand
Material
plastic: clear; blue; red; white
silastic: clear
Inscriptions
The bag the blood tubing set arrived in has printed information on it which reads, "OPEN // Cat. No
M3-9605/9795 // Lot No. 1809k3 // 1 unit // Arterial-Venous // Blood Tubing Set // For single use
only // Sterile nonpyrogenic fluid path. // Do not use if tip protectors are not in place. // See
directions enclosed in carton prior to use. // CAUTION: Federal (USA) Law restricts this device to
sale by or on order of a physician. // Manufactured for: // Medisystems // CORPORATION // San Francisco,
CA 94104 // Made in Thailand"
Permanent Location
Storage Room 0010
0010-E7-2
Condition Remarks
The tubing set arrived sealed in a plastic bag and has never been used; all parts are complete and undamaged; #2: rubber requires special treatment.
Copy Type
Original
Reference Types
Person
Other
Reference Comments
Dr. Peter Morrin; see also 998.020.024 and .026
Less detail

arterial-venous blood tubing set

http://mhc.andornot.com/en/permalink/artifact26
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020026 a-b
Description
Hemodialysis arterial-venous blood tubing set, which consists of two lengths of silastic tubing with plastic attachments; the arterial blood tubing set (a) consists of a cylindrical hollow clear plastic chamber with covered ends, both of which have lengths of silastic tubing coming from them; the t…
Accession Number
998020026 a-b
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Hemodialysis -- instrumentation
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Hemodialysis arterial-venous blood tubing set, which consists of two lengths of silastic tubing with plastic attachments; the arterial blood tubing set (a) consists of a cylindrical hollow clear
plastic chamber with covered ends, both of which have lengths of silastic tubing coming from them; the top of the chamber has a long length of silastic tubing and a short length; there are also two
short lengths of tubing leading off from the main tube; all tube ends have attached caps and the small tube pieces have attached rounded clips which can be clicked closed to pinch the tube closed; the bottom of the chamber has a long length of silastic tubing with a plastic cap at the end and a clip on the tube just above the cap; all plastic end pieces are either red or clear in colour; the clips are all made of white plastic; the venous blood tubing set (b) consists of a cylindrical hollow clear plastic chamber with covered ends, both of which have lengths of silastic tubing coming from them; the top of the chamber has a long length of silastic tubing and two short lengths coming
out from it; all tube ends have attached caps and the small tube pieces have attached rounded plastic clips which can be clicked closed to pinch the tube closed; the bottom of the chamber has a
long length of silastic tubing with an attached cap at the end and a clip on the tube just above the cap; all plastic end pieces are either blue or white in colour; the clips are all made of white plastic; Note: item is missing.
Number Of Parts
2
Part Names
a - arterial blood tubing set - Size: Length 409.5 cm. x Diameter2.8 cm.
b - venous blood tubing set - Size: Length 303.3 cm. x Diameter2.2
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Medisystems Corporation
Site Made (Country)
Thailand
Material
plastic: clear; blue; red; white
silastic: clear
Inscriptions
The bag the blood tubing set arrived in has printed information on it which reads, "OPEN // Cat. No
M3-9605/9795 // Lot No. 2X12k1 // 1 unit // Arterial-Venous // Blood Tubing Set // For single use
only // Sterile nonpyrogenic fluid path. // Do not use if tip protectors are not in place. // See
directions enclosed in carton prior to use. // CAUTION: Federal (USA) Law restricts this device to
sale by or on order of a physician. // Manufactured for: // Medisystems // CORPORATION // San Francisco,
CA 94104 // Made in Thailand"
Permanent Location
Storage Room 0010
0010-E7-2
Temporary Location
Item is missing.
Condition Remarks
The tubing set arrived sealed in a plastic bag and has never been used; all parts are complete and
undamaged
Copy Type
Original
Reference Types
Person
Other
Reference Comments
Dr. Peter Morrin; see also 998.020.024 and .025
Less detail

arterial venous fistula needle set

http://mhc.andornot.com/en/permalink/artifact47
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020047 a-c
Description
Nipro hemodialysis arterial venous fistula needle set with clamp, which consists of (a) a length of hollow cylindrical silastic tubing with a needle at one end and a capped opening at the other end; the needle is made of cylindrical hollow metal and has a bevelled tip; it is covered with (b) a remo…
Accession Number
998020047 a-c
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Hemodialysis -- instrumentation
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Nipro hemodialysis arterial venous fistula needle set with clamp, which consists of (a) a length
of hollow cylindrical silastic tubing with a needle at one end and a capped opening at the other
end; the needle is made of cylindrical hollow metal and has a bevelled tip; it is covered with
(b) a removable piece of hollow cylindrical plastic tubing that is open at both ends; there is a
piece of bow-shaped flat plastic on the tube at the base of the needle; the middle of the silastic
tube has a rounded plastic clip that clamps the tube closed when clicked shut; the other end of the
silastic tube has an attached piece of hollow cylindrical plastic with a round open end that is
capped with (c) a round screw-off cap; the fistula needle arrived sealed in a paper and plastic
package; there is printed manufacturing information on the bottom paper piece
Number Of Parts
3
Part Names
a - fistula needle - Size: Length 35.5 cm. x Width 3.4 cm. x Depth 0.8 cm.
b - needle protector - Size: Length 4.1 cm. x Diameter0.7 cm.
c - cap - Size: Length 1.0 cm. x Diameter0.9 cm.
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Nipro Medical Industries Co., Ltd.
Site Made (City)
Tokyo
Site Made (Country)
Japan
Material
plastic: clear; white; cream
metal: silver
silastic: opaque
Inscriptions
The package bottom reads, "Nipro ® // 15G X 1 1/4" // 1.80
X 32 mm // TUBE: // I.D. 2.9 mm Length 300 mm // Capacity 2.2 ml // ULTRA THIN WALL // E.O. GAS STERILIZED PYROGEN-FREE // NIPRO ARTERIAL VENOUS FISTULA NEEDLE SET // WITH CLAMP // LOT NO. 91J23 // DO NOT STORE AT EXTREME TEMPERATURE AND HUMIDITY. // Manufactured by // NIPRO MEDICAL INDUSTRIES
CO., LTD. TOKYO, JAPAN."
Permanent Location
Storage Room 0010
0010-E7-5
Condition Remarks
The fistula needle set arrived sealed in a paper and plastic package, and has never been used;
all parts are complete and undamaged
Copy Type
Original
Reference Types
Person
Other
Reference Comments
Dr. Peter Morrin; same as 998.020.048a-c and .049a-c
Less detail

arterial venous fistula needle set

http://mhc.andornot.com/en/permalink/artifact48
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020048 a-c
Description
Nipro hemodialysis arterial venous fistula needle set with clamp, which consists of (a) a length of hollow cylindrical silastic tubing with a needle at one end and a capped opening at the other end; the needle is made of cylindrical hollow metal and has a bevelled tip; it is covered with (b) a remo…
Accession Number
998020048 a-c
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Hemodialysis -- instrumentation
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Nipro hemodialysis arterial venous fistula needle set with clamp, which consists of (a) a length
of hollow cylindrical silastic tubing with a needle at one end and a capped opening at the other
end; the needle is made of cylindrical hollow metal and has a bevelled tip; it is covered with
(b) a removable piece of hollow cylindrical plastic tubing that is open at both ends; there is a
piece of bow-shaped flat plastic on the tube at the base of the needle; the middle of the silastic
tube has a rounded plastic clip that clamps the tube closed when clicked shut; the other end of the
silastic tube has an attached piece of hollow cylindrical plastic with a round open end that is
capped with (c) a round screw-off cap; the fistula needle arrived sealed in a paper and plastic
package; there is printed manufacturing information on the bottom paper piece
Number Of Parts
3
Part Names
a - fistula needle - Size: Length 35.5 cm. x Width 3.4 cm. x Depth 0.8 cm.
b - needle protector - Size: Length 4.1 cm. x Diameter0.7 cm.
c - cap - Size: Length 1.0 cm. x Diameter0.9 cm.
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Nipro Medical Industries Co., Ltd.
Site Made (City)
Tokyo
Site Made (Country)
Japan
Material
plastic: clear; white; cream
metal: silver
silastic: opaque
Inscriptions
The package bottom reads, "Nipro ® // 15G X 1 1/4" // 1.80
X 32 mm // TUBE: // I.D. 2.9 mm Length 300 mm // Capacity 2.2 ml // ULTRA THIN WALL // E.O. GAS STERILIZED PYROGEN-FREE // NIPRO ARTERIAL VENOUS FISTULA NEEDLE SET // WITH CLAMP // LOT NO. 91J23 // DO NOT STORE AT EXTREME TEMPERATURE AND HUMIDITY. // Manufactured by // NIPRO MEDICAL INDUSTRIES
CO., LTD. TOKYO, JAPAN."
Permanent Location
Storage Room 0010
0010-E7-5
Condition Remarks
The fistula needle set arrived sealed in a paper and plastic package, and has never been used;
all parts are complete and undamaged
Copy Type
Original
Reference Types
Person
Other
Reference Comments
Dr. Peter Morrin; same as 998.020.047a-c and .049a-c
Less detail

arterial venous fistula needle set

http://mhc.andornot.com/en/permalink/artifact49
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020049 a-c
Description
Nipro hemodialysis arterial venous fistula needle set with clamp, which consists of (a) a length of hollow cylindrical silastic tubing with a needle at one end and a capped opening at the other end; the needle is made of cylindrical hollow metal and has a bevelled tip; it is covered with (b) a remo…
  2 images  
Accession Number
998020049 a-c
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Hemodialysis -- instrumentation
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Nipro hemodialysis arterial venous fistula needle set with clamp, which consists of (a) a length
of hollow cylindrical silastic tubing with a needle at one end and a capped opening at the other
end; the needle is made of cylindrical hollow metal and has a bevelled tip; it is covered with
(b) a removable piece of hollow cylindrical plastic tubing that is open at both ends; there is a
piece of bow-shaped flat plastic on the tube at the base of the needle; the middle of the silastic
tube has a rounded plastic clip that clamps the tube closed when clicked shut; the other end of the
silastic tube has an attached piece of hollow cylindrical plastic with a round open end that is
capped with (c) a round screw-off cap; the fistula needle arrived sealed in a paper and plastic
package; there is printed manufacturing information on the bottom paper piece
Number Of Parts
3
Part Names
a - fistula needle - Size: Length 35.5 cm. x Width 3.4 cm. x Depth 0.8 cm.
b - needle protector - Size: Length 4.1 cm. x Diameter0.7 cm.
c - cap - Size: Length 1.0 cm. x Diameter0.9 cm.
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Nipro Medical Industries Co., Ltd.
Site Made (City)
Tokyo
Site Made (Country)
Japan
Material
plastic: clear; white; cream
metal: silver
silastic: opaque
Inscriptions
The package bottom reads, "Nipro ® // 15G X 1 1/4" // 1.80
X 32 mm // TUBE: // I.D. 2.9 mm Length 300 mm // Capacity 2.2 ml // ULTRA THIN WALL // E.O. GAS STERILIZED PYROGEN-FREE // NIPRO ARTERIAL VENOUS FISTULA NEEDLE SET // WITH CLAMP // LOT NO. 91J23 // DO NOT STORE AT EXTREME TEMPERATURE AND HUMIDITY. // Manufactured by // NIPRO MEDICAL INDUSTRIES
CO., LTD. TOKYO, JAPAN."
Permanent Location
Storage Room 0010
0010-E7-5
Condition Remarks
The fistula needle set arrived sealed in a paper and plastic package, and has never been used;
all parts are complete and undamaged
Copy Type
Original
Reference Types
Person
Other
JPG
Reference Comments
Dr. Peter Morrin; same as 998.020.047a-c and .048a-c; CD #10.
Images
Less detail

automated PD set with cassette

http://mhc.andornot.com/en/permalink/artifact55
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020055 a-b
Description
HomeChoice automated peritoneal dialysis set with cassette in plastic package, which consists of (a) the automated PD set wtih cassette, that has a thin blue plastic form made to hold 6 lengths of silastic tubing; four of these tubes have white plastic bevelled tips with round plastic protectors at…
  2 images  
Accession Number
998020055 a-b
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Dialysis Solutions -- administration and dosage
Peritoneal Dialysis -- instrumentation
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
HomeChoice automated peritoneal dialysis set with cassette in plastic package, which consists of
(a) the automated PD set wtih cassette, that has a thin blue plastic form made to hold 6 lengths
of silastic tubing; four of these tubes have white plastic bevelled tips with round plastic protectors
at the top; five of these tubes have rounded plastic clips that close the tube if clicked
shut; the outer two lengths of tubing have round open tops with rounded blue plastic caps; two of
the tubes join together and the remaining 5 tubes end by attaching to a flat four-sided clear plastic
cassette; the inside of the cassette has several compartments; one of the tubes has an attached
short length of silastic tubing with a rounded plastic cap that closes the tube if clicked shut;
the end of this piece of tubing is round and open and has a rounded plastic cap
Number Of Parts
2
Part Names
a - automated PD set with cassette - Size: Length 113.6 cm. x Width 18.2 cm. x Depth 2.2 cm.
b - plastic package - Size: Length 32.0 cm. x Width 42.0 cm.
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Baxter Healthcare Corporation
Site Made (City)
Deerfield
Site Made (State)
Illinois
Site Made (Country)
United States of America
Material
plastic: clear; white; blue; red
silastic: clear
Inscriptions
The bag (b) reads, "LOT H98K20538 // 5C4469 // Baxter // HomeChoice™ Automated PD Set with Cassette 4-Prong // Sterile, nonpyrogenic fluid path // Sterilized by ethylene oxide
// Do not use if the protectors are not in place. // See accompanying directions for use. // Caution:
Federal (USA) law restricts this device to sale by or on // order of a physician. // Baxter
Healthcare Corporation // Deerfield, IL 60015 USA // Made in USA // U.S. Pat. Nos. 4,346,703;
4,439,188; 5,088,515; Pat Pending // 7-7-1-829 // 9315 // GRASP TO OPEN"
Permanent Location
Storage Room 0010
0010-E7-2
Condition Remarks
The HomeChoice PD set arrived sealed in a plastic package, and thus has never been used; no damage is visible and all printing is fully legible; #2: rubber requires special treatment.
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Karen Irvine-Bird; CD #10.
Research Facts
Used with a HomeChoice TM automated continuous cycling peritoneal dialysis machine
Images
Less detail

basket extractor

http://mhc.andornot.com/en/permalink/artifact10571
Dates
1920
circa 1920
Collection
Dr. A. Morales Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
004001005
Description
A metal instrument consisting of a handle with three rings for the thumb as the rear and two for the first two fingers of the hand; the thumb ring is used to push the rest of the object back and forth; extending from the handle is a long, thin, coiled wire with seven thin wires at the end that exp…
  1 image  
Accession Number
004001005
Collection
Dr. A. Morales Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Kidney Calculi
Nephrology -- instrumentation
Description
A metal instrument consisting of a handle with three rings for the thumb as the rear and two for the first two fingers of the hand; the thumb ring is used to push the rest of the object back and forth; extending from the handle is a long, thin, coiled wire with seven thin wires at the end that expand out, then contract in and meet to form a point where a grey plastic curved apparatus is attached.
Number Of Parts
1
Provenance
Owned and used by Dr. A. Morales, KGH Urology Dept.
Dates
1920
circa 1920
Material
metal: silver
plastic: grey
Inscriptions
"G [inside a circle]" on the handle; "A.C.M.L. 5" on the plastic section.
Permanent Location
Storage Room 0010
0010-E7-6
Dimension Notes
Length 70.7 cm x Width 6.4 cm x Depth 1.7 cm
Condition Remarks
Minor wear on surfaces.
Copy Type
Original
Reference Types
JPG
Reference Comments
CD #1
Images
Less detail

blood tubing set

http://mhc.andornot.com/en/permalink/artifact36
Dates
1996
circa 1996
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020036 a-c
Description
Hemodialysis blood tubing set, which consists of three parts: (a) the arterial blood tubing set that consists of a cylindrical hollow clear plastic chamber with covered ends, both of which have lengths of silastic tubing coming out from them; the top of the chamber has a long length of silastic tub…
  1 image  
Accession Number
998020036 a-c
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Hemodialysis -- instrumentation
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Hemodialysis blood tubing set, which consists of three parts: (a) the arterial blood tubing set
that consists of a cylindrical hollow clear plastic chamber with covered ends, both of which have
lengths of silastic tubing coming out from them; the top of the chamber has a long length of silastic
tubing and two short lengths; all tube ends have removable plastic caps; all tube lengths
have rounded plastic clips that pinch the tube closed when clicked shut; the long length of tubing
has another short length coming off it; the end of this piece also has a removable cap and there is
a plastic clip on the tube; the bottom of the chamber tapers to a long length of silastic tubing
that has a removable cap at the end; there is a shorter, narrower length of tubing coming off this
main length; this piece of tubing has a removable cap at the end and a plastic tube clip; there is
also a venous blood tubing set (b) which consists of a cylindrical hollow clear plastic chamber
with covered ends, both of which have lengths of silastic tubing coming from them; the top of the
chamber has a long length of silastic tubing and two short lengths; all the tubes have removable
plastic caps and the short lengths also have plastic tube clips; the bottom of the chamber tapers
to a long length of silastic tubing that has a removable cap at the end and a tube clip on the tube;
there is also a connecting tubing set (c) that consists of a length of silastic tubing with a hollow
cylindrical chamber at one end; the open end of the chamber tapers to a bevelled point that has
a removable rounded cap; the other end of the silastic tube has a round open plastic piece and a
removable plastic cap; the tube near this end has a plastic roller attachment that will pinch the
tube closed when rolled forward
Number Of Parts
3
Part Names
a - arterial blood tubing set - Size: Length 401.5 cm. x Diameter2.3 cm.
b - venous blood tubing set - Size: Length 301.4 cm. x Diameter2.3 cm.
c - connecting tubing set - Size: Length 145.4 cm. x Width 3.9 cm. x Depth 1.9 cm.
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Medisystems Corporation
Site Made (Country)
Thailand
Dates
1996
circa 1996
Date Remarks
Sterilized in September of 1996
Material
plastic: clear; blue; white; red
silastic: opaque
Inscriptions
The plastic bag the blood tubing set arrived in has printed manufacturing information on the front
that reads, "Code: D3-9692-9793 // Lot No: 6907K4 // Sterilized SEP 96 // Pump Segment: 8 mm ID //
MEDISYSTEMS // Ready Set™ HEMODIALYSIS BLOOD TUBING SET // with Priming Set and
Transducer Protectors. // Sterile non-pyrogenic fluid pathway. // Disposable, DO NOT REUSE. // Do
not use of protective sterility caps are not in place. // See directions enclosed in carton prior
to use. // CAUTION: Federal (USA) law restricts this device to sale by or on order of a physician.
// VENT // 1 // PAIR // VENT // MANUFACTURED FOR: // MEDISYSTEMS CORPORATION // SEATTLE, WA 98101-3016
// MADE IN THAILAND // QUESTIONS? COMMENTS? // CALL TOLL FREE 1-800-369-MEDI // LBL-BT01 REV
12/93"
Permanent Location
Storage Room 0010
0010-E7-2
Temporary Location
On display, Queen's University Department of Medicine third floor, August 20, 2013.
Condition Remarks
The blood tubing set arrived sealed in a plastic bag and is unused; all parts are complete and undamaged
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Peter Morrin; CD #10.
Images
Less detail

CAPD disconnect Y-set

http://mhc.andornot.com/en/permalink/artifact5
Dates
1985
circa 1985
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020005
Description
Continuous Ambulatory Peritoneal Dialysis disposable disconnect Y-set, which consists of a hollow cylindrical silastic tube with plastic attachments at both ends; at one end, the tube has a Yconnector that allows it to split off into two tubes; each end of the split-off tubes has a cylindrical plas…
  2 images  
Accession Number
998020005
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Dialysis Solutions -- administration and dosage
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Continuous Ambulatory Peritoneal Dialysis disposable disconnect Y-set, which consists of a hollow
cylindrical silastic tube with plastic attachments at both ends; at one end, the tube has a Yconnector
that allows it to split off into two tubes; each end of the split-off tubes has a cylindrical
plastic attachment tip and a square gripping piece; each tip has a rounded plastic cap; the
other end of the main tube has an attached rectangular plastic bag; this bag is sealed on all sides
and attaches at the tube; it is designed to hold dialysis fluid; there are two plastic clips along
the length of the main tube; the whole set is sealed in a plastic bag
Number Of Parts
1
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Baxter Healthcare Corporation
Site Made (Country)
Dominican Republic
Dates
1985
circa 1985
Date Remarks
Used in the late 1980's and 1990's
Material
silastic: opaque
plastic: white; blue; clear
Inscriptions
The front of the bag reads, "LOT Z154435 // 5C4366 // Baxter // Ultra Set // CAPD Disposable Disconnect
Y-Set // 1.1 m (42") long (approx.) // Sterile, nonpyrogenic fluid path // Do not use if
tip protectors are not in place. // Sterilized with gamma irradiation. // This set is intended to
be discarded after each exchange. // See accompanying directions for use. // Warning: Do not apply
alcohol or antiseptic agents containing alcohol to the spike or // male Luer lock connector. //
Caution: Federal (USA) law restricts this device to sale by or on order of a physician. // Manufactured
by an affiliate of // Baxter Healthcare Corporation // Deerfield IL 60015 USA // Made in
the Dominican Republic // U.S. Pat. Nos. 4,346,703; 4,439,188; DES 300,177 // 7-7-1-641 // 92/4
// GRASP TO OPEN."
Permanent Location
Storage Room 0010
0010-E7-1
Dimension Notes
Length: 21.0 cm. x Width: 34.2 cm. x Depth: 2.8 cm.
Condition Remarks
The Y-set is unused and has never been removed from its original packaging; all printing on the package is fully legible; #2: rubber requires special treatment
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Peter Morrin; Karen Irvine-Bird; CD #10.
Research Facts
Silastic is a silicone rubber product; this set was used for infusion and draining of dialysis fluid
Images
Less detail

CAPD solution transfer set

http://mhc.andornot.com/en/permalink/artifact3
Dates
1980
circa 1980
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020003
Description
Continuous Ambulatory Peritoneal Dialysis solution transfer set, which consists of a long narrow hollow silastic tube with plastic attachments on both ends; one end has a cylindrical piece of white plastic that attaches to the tube on one end and has a short length of hollow opaque plastic tubing w…
  2 images  
Accession Number
998020003
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Dialysis Solutions -- administration and dosage
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Continuous Ambulatory Peritoneal Dialysis solution transfer set, which consists of a long narrow
hollow silastic tube with plastic attachments on both ends; one end has a cylindrical piece of
white plastic that attaches to the tube on one end and has a short length of hollow opaque plastic
tubing with an open bevelled edge on the other end; a hollow cylindrical piece of blue plastic
slides over this end attachment and has an open end that exposes a bevelled tip; the other end of
the silastic tube has a round hollow white plastic end and an opaque piece of plastic with a round
blue plastic roller; this roller will pinch the tube closed when rolled foreward
Number Of Parts
1
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Baxter Healthcare Corporation
Site Made (City)
Deerfield
Site Made (State)
Illinois
Site Made (Country)
United States of America
Dates
1980
circa 1980
Date Remarks
Used in the 1980's
Material
silastic: opaque
plastic: white; blue; opaque
Permanent Location
Storage Room 0010
0010-E7-1
Dimension Notes
Length: 134.0 cm. x Width: 1.9 cm. x Depth: 1.5 cm.
Condition Remarks
#2: rubber requires special treatment.
Copy Type
Original
Reference Types
Person
Other
JPG
Reference Comments
Dr. Peter Morrin; Karen Irvine-Bird; similar to 998.020.004; CD #10.
Research Facts
Silastic is a silicone rubber product; this set was used for infusion and draining of dialysis fluid
Images
Less detail

CAPD solution transfer set

http://mhc.andornot.com/en/permalink/artifact4
Dates
1980
circa 1980
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020004
Description
Continuous Ambulatory Peritoneal Dialysis solution transfer set, which consists of a long narrow hollow silastic tube with plastic attachments on both ends; one end has a cylindrical piece of white plastic that attaches to the tube on one end and has a short length of hollow opaque plastic tubing w…
  2 images  
Accession Number
998020004
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Dialysis Solutions -- administration and dosage
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Continuous Ambulatory Peritoneal Dialysis solution transfer set, which consists of a long narrow
hollow silastic tube with plastic attachments on both ends; one end has a cylindrical piece of
white plastic that attaches to the tube on one end and has a short length of hollow opaque plastic
tubing with an open bevelled edge on the other end; a hollow cylindrical piece of blue plastic
slides over this end attachment and has an open end that exposes a bevelled tip; the other end of
the silastic tube has a round hollow white plastic end and an opaque piece of plastic with a round
blue plastic roller; this roller will pinch the tube closed when rolled foreward; both end pieces
are capped with cylindrical clear plastic covers; the whole set is sealed in a paper and plastic bag
Number Of Parts
1
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Baxter Healthcare Corporation
Site Made (City)
Deerfield
Site Made (State)
Illinois
Site Made (Country)
United States of America
Dates
1980
circa 1980
Date Remarks
Used in the 1980's
Material
silastic: opaque
plastic: white; blue; opaque; clear
paper: white
Inscriptions
The front end of the bag reads, "To Open Peel Down // 5C4304 // Baxter // CAPD Solution Transfer Set
// for Germicidal Exchange Device // 1.2m (48") long (approx.) // Sterile, nonpyrogenic // Do not
use if package has been previously opened or damaged. // See accompanying directions for use. //
Warnings: [listed] Do not allow any part of the connection system to come into contact with lotions,
creams, or // oils // Caution: Federal (USA) law restricts this device to sale by or on order of a
physician. // Baxter Healthcare Corporation // Deerfield IL 60015 USA // Made in USA // U.S. Pat.
Nos. 4,346,703; 4,349,188 // 7-7-20-89 // 89/2 Lot // H91J17442"
Permanent Location
Storage Room 0010
0010-E7-1
Dimension Notes
Length: 18.6 cm. x Width: 24.7 cm. x Depth: 1.6 cm.
Condition Remarks
The transfer set is unused and has never been removed from its original packaging; the paper and plastic package shows folds and creases, but is sealed and complete; all printing on the package is fully legible; #2: rubber requires special treatment.
Copy Type
Original
Reference Types
Person
Other
JPG
Reference Comments
Dr. Peter Morrin; Karen Irvine-Bird; similar to 998.020.003; CD #10.
Research Facts
Silastic is a silicone rubber product; this set was used for infusion and draining of dialysis fluid;
a germicidal exchange device would cut down on peritoneal infections
Images
Less detail

capillary dialyzer

http://mhc.andornot.com/en/permalink/artifact18
Dates
1995
circa 1995
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020018
Description
Hemoflow F6 capillary dialyzer for hemodialysis, which consists of a cylindrical clear plastic hollow tube with round screw-on caps at both ends; the caps have been glued in place and have short cylindrical pieces on top with ends that twist off to allow access to a small round opening into the tub…
  2 images  
Accession Number
998020018
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Hemofiltration -- instrumentation
Hemodialysis -- instrumentation
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Hemoflow F6 capillary dialyzer for hemodialysis, which consists of a cylindrical clear plastic hollow
tube with round screw-on caps at both ends; the caps have been glued in place and have short
cylindrical pieces on top with ends that twist off to allow access to a small round opening into
the tube; the tube is filled with thousands of white fibres that run the length of the tube; the
outside front of the tube has a plasticized paper label stuck to it; this label has printed manufacturing
information on it; the back top and bottom of the tube has attached small cylindrical
pieces of tubing coming out from the tube; these pieces are open at the unattached ends
Number Of Parts
1
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Fresenius USA
Site Made (City)
Ogden
Site Made (State)
Utah
Site Made (Country)
United States of America
Dates
1995
circa 1995
Date Remarks
Sterilized in Dec. 1995
Material
plastic: clear; brown
fibres: white
paper: white
Inscriptions
The label on the front reads, "Hemoflow // F6 // Capillary dialyzer. Ethylene // oxide sterilized. Refer to instruc- // tions [in English, French and Spanish] // Fresenius Polysulfone // UF 5.5 //
Batch no. 5N02508 // Date of Sterilization 12/95 // Fresenius USA // OGDEN, UTAH 84404 // MADE IN U.S.A. // 89-701-02 REV 2/95"
Permanent Location
Storage Room 0010
0010-E7-4
Dimension Notes
Length: 29.8 cm. x Width: 6.0 cm. x Depth: 8.8 cm.
Condition Remarks
The dialyzer arrived sealed in a paper and plastic envelope and has never been used; all parts are
complete and undamaged
Copy Type
Original
Reference Types
Person
Other
JPG
Reference Comments
Karen Irvine-Bird; see also 998.020.019 and .020; similar to 998.020.042; CD #10.
Research Facts
Also called a hollow fibre dialyzer.
Images
Less detail

capillary dialyzer

http://mhc.andornot.com/en/permalink/artifact19
Dates
1995
circa 1995
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020019
Description
Hemoflow F6 capillary dialyzer for hemodialysis, which consists of a cylindrical clear plastic hollow tube with round screw-on caps at both ends; the caps have been glued in place and have short cylindrical pieces on top with ends that twist off to allow access to a small round opening into the tub…
Accession Number
998020019
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Hemofiltration -- instrumentation
Hemodialysis -- instrumentation
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Hemoflow F6 capillary dialyzer for hemodialysis, which consists of a cylindrical clear plastic hollow
tube with round screw-on caps at both ends; the caps have been glued in place and have short
cylindrical pieces on top with ends that twist off to allow access to a small round opening into
the tube; the tube is filled with thousands of white fibres that run the length of the tube; the
outside front of the tube has a plasticized paper label stuck to it; this label has printed manufacturing
information on it; the back top and bottom of the tube has attached small cylindrical
pieces of tubing coming out from the tube; these pieces are open at the unattached ends
Number Of Parts
1
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Fresenius USA
Site Made (City)
Ogden
Site Made (State)
Utah
Site Made (Country)
United States of America
Dates
1995
circa 1995
Date Remarks
Sterilized in Dec. 1995
Material
plastic: clear; brown
fibres: white
paper: white
Inscriptions
The label on the front reads, "Hemoflow // F6 // Capillary dialyzer. Ethylene // oxide sterilized.
Refer to instruc- // tions [in English, French and Spanish] // Fresenius Polysulfone // UF 5.5 //
Batch no. 5N02508 // Date of Sterilization 12/95 // Fresenius USA // OGDEN, UTAH 84404 // MADE IN
U.S.A. // 89-701-02 REV 2/95"
Permanent Location
Storage Room 0010
0010-E7-4
Dimension Notes
Length: 29.8 cm. x Width: 6.0 cm. x Depth: 8.8 cm.
Condition Remarks
The dialyzer arrived sealed in a paper and plastic envelope and has never been used; all parts are
complete and undamaged
Copy Type
Original
Reference Types
Person
Other
Reference Comments
Karen Irvine-Bird; see also 998.020.018 and .020; similar to 998.020.042
Research Facts
Also called a hollow fibre dialyzer
Less detail

capillary dialyzer

http://mhc.andornot.com/en/permalink/artifact20
Dates
1995
circa 1995
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020020
Description
Hemoflow F6 capillary dialyzer for hemodialysis, which consists of a cylindrical clear plastic hollow tube with round screw-on caps at both ends; the caps have been glued in place and have short cylindrical pieces on top with ends that twist off to allow access to a small round opening into the tub…
Accession Number
998020020
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Hemofiltration -- instrumentation
Hemodialysis -- instrumentation
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Hemoflow F6 capillary dialyzer for hemodialysis, which consists of a cylindrical clear plastic hollow
tube with round screw-on caps at both ends; the caps have been glued in place and have short
cylindrical pieces on top with ends that twist off to allow access to a small round opening into
the tube; the tube is filled with thousands of white fibres that run the length of the tube; the
outside front of the tube has a plasticized paper label stuck to it; this label has printed manufacturing
information on it; the back top and bottom of the tube has attached small cylindrical
pieces of tubing coming out from the tube; these pieces are open at the unattached ends
Number Of Parts
1
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Fresenius USA
Site Made (City)
Ogden
Site Made (State)
Utah
Site Made (Country)
United States of America
Dates
1995
circa 1995
Date Remarks
Sterilized in Dec. 1995
Material
plastic: clear; brown
fibres: white
paper: white
Inscriptions
The label on the front reads, "Hemoflow // F6 // Capillary dialyzer. Ethylene // oxide sterilized.
Refer to instruc- // tions [in English, French and Spanish] // Fresenius Polysulfone // UF 5.5 //
Batch no. 5N02508 // Date of Sterilization 12/95 // Fresenius USA // OGDEN, UTAH 84404 // MADE IN
U.S.A. // 89-701-02 REV 2/95"
Permanent Location
Storage Room 0010
0010-E7-4
Dimension Notes
Length: 29.8 cm. x Width: 6.0 cm. x Depth: 8.8 cm.
Condition Remarks
The dialyzer arrived sealed in a paper and plastic envelope and has never been used; all parts are
complete and undamaged
Copy Type
Original
Reference Types
Person
Other
Reference Comments
Karen Irvine-Bird; see also 998.020.018 and .019; similar to 998.020.042
Research Facts
Also called a hollow fibre dialyzer
Less detail

capillary dialyzer

http://mhc.andornot.com/en/permalink/artifact42
Dates
1990
circa 1990
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020042
Description
Hemoflow F4 capillary dialyzer for hemodialysis, which consists of a cylindrical clear plastic hollow tube with round screw-on caps at both ends; the caps have been glued in place and have short cylindrical pieces on top with ends that twist off to allow access to a small round opening in the tube;…
  2 images  
Accession Number
998020042
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Hemofiltration -- instrumentation
Hemodialysis -- instrumentation
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Hemoflow F4 capillary dialyzer for hemodialysis, which consists of a cylindrical clear plastic hollow
tube with round screw-on caps at both ends; the caps have been glued in place and have short
cylindrical pieces on top with ends that twist off to allow access to a small round opening in the
tube; the tube is filled with thousands of white fibers that run the length of the tube; the outside
front of the tube has a paper label stuck to it; this label has printed manufacturing information
on it; the back top and bottom of the tube has attached small hollow cylindrical pieces of tubing
coming out from the tube; these pieces are open at the unattached ends
Number Of Parts
1
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Fresenius AG
Site Made (City)
Bad Homburg
Site Made (Country)
Germany
Dates
1990
circa 1990
Date Remarks
Sterilized in January 1990
Material
plastic: clear; brown
fibers: white
paper: white
Inscriptions
The label on the front reads, "Fresenius // Hemoflow // F4 // Hollow Fiber Dialyzer // Ethylene oxide
sterilized. For single use only. // Refer to instructions. // Batch Number AAF 174 // Date of
sterilization 01.90 // Expiration date 30.06.92 [in German, English, French, and Spanish] // Fresenius
AG . Bad Homburg // D-6380 Bad Homburg v.d.H. // Postfach 1480 . Tel. 06171/60-0 // 7503591
/01"
Permanent Location
Storage Room 0010
0010-E7-4
Dimension Notes
Length: 29.5 cm. x Width: 4.3 cm. x Depth: 7.2 cm.
Condition Remarks
The dialyzer arrived sealed in a paper and plastic envelope and has never been used; all parts are
complete and undamaged
Copy Type
Original
Reference Types
Person
Other
JPG
Reference Comments
Dr. Peter Morrin; similar to 998.020.018-.020; CD #10.
Research Facts
Also called a hollow fibre dialyzer
Images
Less detail

coil dialyzer

http://mhc.andornot.com/en/permalink/artifact40
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020040 a-b
Description
Travenol standard coil dialyzer, which consists of (a) a cylindrical clear plastic casing with a rounded piece on one side; the top and bottom of the casing have plastic caps and the inside has coiled cuprophan membrane in it; the top of the dialyzer has two lengths of silastic tubing coming from i…
  1 image  
Accession Number
998020040 a-b
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Hemofiltration -- instrumentation
Hemodialysis -- instrumentation
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Travenol standard coil dialyzer, which consists of (a) a cylindrical clear plastic casing with a
rounded piece on one side; the top and bottom of the casing have plastic caps and the inside has
coiled cuprophan membrane in it; the top of the dialyzer has two lengths of silastic tubing coming
from it -- inlet and outlet tubes; one tube has a rounded white plastic attachment and the
other has a blue and white rounded attachment; the bottom of the dialyzer has two round openings
-- one which runs the length of the dialyzer and the other that exposes the coiled membrane inside;
the dialyzer is housed in (b) a cylindrical plastic casing with a tapered closed bottom and
a top with a folded-over outer lip
Number Of Parts
2
Part Names
a - coil dialyzer - Size: Length 28.7 cm. x Width 10.2 cm. x Depth 8.5 cm.
b - dialyzer casing - Size: Length 32.4 m. x Diam. 13.4 cm.
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Travenol Laboratories Inc., Artificial Organs Division
Site Made (City)
Deerfield
Site Made (State)
Illinois
Site Made (Country)
United States of America
Material
plastic: white; clear; blue
cuprophan: off-white
silastic: clear
paper: white
Inscriptions
Both pieces have an attached plastic label that reads, "One // 5M1761 TRAVENOL // CO ™ COIL DIALYZER -- // STANDARD // Sterile, nonpyrogenic blood path // See accompanying
directions // This unit consists of a coil dialyzer with Cuprophan // membrane tubing, plastic
support, and attached inlet // and outlet tubes with QUIK-KLIK ® connectors. // Do not Store above 40° C (104° F). Avoid excessive // changes
in relative humidity. // Caution: Federal (U.S.A.) law restricts this device to // sale by or on
order of a physician // ARTIFICIAL ORGANS DIVISION // TRAVENOL LABORATORIES, INC. // Deerfield,
Illinois 60015, U.S.A. // 8-26-3-14BB // U.S. Pat. No. 3,394,954 and // Patents Pending"; the
dialyzer has a paper label with printed information that reads, "LOT ZC137H8 // 8-26-53-7A"
Permanent Location
Storage Room 0007
0007-L1-3
Condition Remarks
The dialyzer is complete and unused; the outside edges of both parts show minor scuffmarks; there are no breaks, cracks, or chips in the plastic; the tubes are complete and flexible; #2: the plastic has yellowed slightly; clear plastic is pliable; minor signs of wear on the outer surface; no cracks; printing on white paper label is fading; #3: rubber requires special treatment.
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Peter Morrin; CD #8
Research Facts
Used with a hemodialysis machine
Exhibit History
Renal Dialysis Exhibit at Museum, Feb. 24, 1999-April 19, 2003
Images
Less detail

connector shield

http://mhc.andornot.com/en/permalink/artifact12
Dates
1980
circa 1980
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020012
Description
Continuous Ambulatory Peritoneal Dialysis connector shield, which consists of a piece of green plastic molded to form two hollow semicircles, with a thin flexible join at the back and a latch piece at the front; this design allows the connector shield to be closed, to form a short hollow cylindrica…
  1 image  
Accession Number
998020012
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Peritoneal Dialysis -- instrumentation
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Continuous Ambulatory Peritoneal Dialysis connector shield, which consists of a piece of green plastic
molded to form two hollow semicircles, with a thin flexible join at the back and a latch piece
at the front; this design allows the connector shield to be closed, to form a short hollow cylindrical
piece that is open at both ends; one end has a large-diameter round opening and threading on the
inside; the other end has a smaller-diameter round opening
Number Of Parts
1
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Unknown
Dates
1980
circa 1980
Date Remarks
Used in the early 1980's
Material
plastic: green
Permanent Location
Storage Room 0010
0010-E7-6
Dimension Notes
Length: 2.9 cm. x Diam. 2.2 cm.
Condition Remarks
The foam lining illustrated in the Travenol manual is missing on this connector shield; the plastic
is complete and undamaged
Copy Type
Original
Reference Types
Person
Document
Other
JPG
Reference Comments
Karen Irvine-Bird; CAPD Bag change procedure, Luer-lock type connector manual, distributed by
Travenol, p. 4 (see attached photocopy); also see 998.020.013; CD #10.
Research Facts
The connector shield was used by CAPD patients to securely hold peritoneal catheter tubes to tubes
from dialysis fluid bags
Images
Less detail

connector shield

http://mhc.andornot.com/en/permalink/artifact13
Dates
1980
circa 1980
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020013
Description
Continuous Ambulatory Peritoneal Dialysis connector shield, which consists of a piece of green plastic molded to form two hollow semicircles, with a thin flexible join at the back and a latch piece at the front; this design allows the connector shield to be closed, to form a short hollow cylindrica…
  1 image  
Accession Number
998020013
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Peritoneal Dialysis -- instrumentation
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Continuous Ambulatory Peritoneal Dialysis connector shield, which consists of a piece of green plastic
molded to form two hollow semicircles, with a thin flexible join at the back and a latch piece
at the front; this design allows the connector shield to be closed, to form a short hollow cylindrical
piece that is open at both ends; one end has a large-diameter round opening and threading on the
inside; the other end has a smaller-diameter round opening
Number Of Parts
1
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Unknown
Dates
1980
circa 1980
Date Remarks
Used in the early 1980's
Material
plastic: green
Permanent Location
Storage Room 0010
0010-E7-6
Dimension Notes
Length: 2.9 cm. x Diam. : 2.2 cm.
Condition Remarks
The foam lining illustrated in the Travenol manual is missing on this connector shield; the plastic
is complete and undamaged
Copy Type
Original
Reference Types
Person
Document
Other
JPG
Reference Comments
Karen Irvine-Bird; CAPD Bag change procedure, Luer-lock type connector manual, distributed by
Travenol, p. 4 (see attached photocopy); also see 998.020.012; CD #10.
Research Facts
The connector shield was used by CAPD patients to securely hold peritoneal catheter tubes to tubes
from dialysis fluid bags
Images
Less detail

cycler drainage set

http://mhc.andornot.com/en/permalink/artifact54
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
Accession Number
998020054 a-c
Description
Cycler drainage set, which consists of two cycler drainage bags and a plastic storage bag; the cycler drainage bags (a,b) are both flat sealed square plastic bags with two silastic tubes at the top; one tube has a short length of clear silastic tubing with a cylindrical blue plastic cover at the to…
  2 images  
Accession Number
998020054 a-c
Collection
Kingston General Hospital Renal Dialysis Collection
Category
Diagnostic & Treatment Artifacts
Classification
Nephrology
MeSH Heading
Dialysis Solutions -- administration and dosage
Peritoneal Dialysis -- instrumentation
Renal Insufficiency -- therapy
Nephrology -- instrumentation
Description
Cycler drainage set, which consists of two cycler drainage bags and a plastic storage bag; the cycler
drainage bags (a,b) are both flat sealed square plastic bags with two silastic tubes at the
top; one tube has a short length of clear silastic tubing with a cylindrical blue plastic cover
at the top; the top of this tube is plugged with white cotton (?); there is a rounded white plastic
clip in the middle of this tube which will pinch the tube closed when clicked shut; the other tube
has a length of silastic tubing that ends with a Y-shaped piece, the bottom of which has an open
bevelled cylindrical spike; one part of the Y shape has an open-ended piece of silastic tubing with
a round blue cap; the other Y half leads to the bag and also has a rounded plastic clip that will
pinch the tube closed; both drainage bags come in (c) a sealed rectangular plastic package that
has printed information on the front
Number Of Parts
3
Part Names
a - cycler drainage bag - Size: Length 85.0 cm. x Width 41.3 cm. x Depth 1.7 cm.
b - cycler drainage bag - Size: Length 85.0 cm. x Width 41.3 cm. x Depth 1.7 cm.
c - plastic packaging - Size: Length 33.1 cm. x Width 68.9 cm.
Provenance
From the Renal Dialysis Unit at Kingston General Hospital
Maker
Baxter Healthcare Corporation
Site Made (City)
Deerfield
Site Made (State)
Illinois
Site Made (Country)
United States of America
Material
plastic: clear; white; blue
silastic: clear
fabric: white
Inscriptions
The bag (c) reads, "LOT H96L10216 // 5C4145 // Baxter // Cycler Drainage Set // Sterile, non pyrogenic
fluid path // Do not use if tip protectors are not in // place. // Sterilized by ethylene oxide
// Use aseptic technique // For single use only // Caution: Federal (USA) law restricts this //
device to sale by or on order of a // physician. // Baxter Healthcare Corporation // Deerfield, IL
60015 USA // Made in USA // 7-7-1-619 // 9212 // For use with Cycler Tubing Set (5C4415, // 5C4437,
and 5C4439). Refer // to directions accompanying cycler tubing // set and Peritoneal Dialysis Cycler
// Machine. // GRASP TO OPEN"
Permanent Location
Storage Room 0010
0010-E7-1
Condition Remarks
The cycler drainage set arrived sealed in a plastic package, and thus has never been used; no damage is visible and all printing is fully legible; #2: rubber requires special treatment.
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Karen Irvine-Bird; CD #10.
Research Facts
Drainage set made to be used with a continuous cycling peritoneal dialysis machine
Images
Less detail

66 records – page 1 of 4.