Skip header and navigation

Refine By

102 records – page 1 of 6.

glass lantern slides

https://mhc.andornot.com/en/permalink/artifact428
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
995004012 a-q
Description
(a) 2-piece cardboard box which contains: (b-q) 16 glass lantern plates with lipiodol (spine) studies as subjects; the x-ray photographs on the glass plates show various views of the human spine
  3 images  
Accession Number
995004012 a-q
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
X-Ray Film
Radiography -- instrumentation
Description
(a) 2-piece cardboard box which contains: (b-q) 16 glass lantern plates with lipiodol (spine) studies as subjects; the x-ray photographs on the glass plates show various views of the human spine
Number Of Parts
17
Part Names
a - cardboard box - Size: Length 9.2 cm. x Width 9.1 cm. x Depth 2.3 cm.
b-q - lantern plates x 16 - Size: Length 8.3 cm. x Width 8.3 cm.
Provenance
Given to the School of X-Ray by Dr. Wollin
Maker
Ilford Ltd.
Site Made (City)
Essex
Site Made (Country)
England
Material
cardboard: beige
glass: clear
emulsion: grey
Inscriptions
Label on box top reads: "Ilford Special Lantern Plates H. + D. 9"; written in ink on the box top is, "These were the first lipiodol studies in England for H. Cairns (Sir) C.P. Symonds (Sir) Julian Taylor, E.L. Kingston Riddoch, etc."; written on box side in pencil: "Lipiodol (Spine)"
Permanent Location
Storage Room 0010
0010-F3-3
Condition Remarks
(a) Cardboard box top is broken at the two lower corners; the whole box appears to be very acidic and the covering paper is flaking off in some areas; (b-q) slides are dusty and have fingerprints on them; there are no broken, chipped, cracked or scratched slides
Copy Type
Original
Reference Types
Person
Book
JPG
Reference Comments
Nancy Chisholm; "The Trail of the Invisible Light" by E.R.N. Grigg, M.D.; CD #4
Research Facts
First use of early oil based contrast media
Images
Less detail

valve tube; rectifier tube

https://mhc.andornot.com/en/permalink/artifact437
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
995004021
Description
Early valve rectifier tube which consists of a cylindrical glass tube with a rounded centre; the glass tube has two plastic-capped ends, the top end has a short metal rod sticking out of it; the bottom end has a screw attachment (similar to a light bulb) coming out of it; there are cylindrical meta…
  1 image  
Accession Number
995004021
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Radiography -- instrumentation
MM= Radiography -- tube
Description
Early valve rectifier tube which consists of a cylindrical glass tube with a rounded centre;
the glass tube has two plastic-capped ends, the top end has a short metal rod sticking out of
it; the bottom end has a screw attachment (similar to a light bulb) coming out of it; there
are cylindrical metal pieces within the glass tube itself; the tube screws onto a plastic
and wood base
Number Of Parts
1
Provenance
From Professor Thumm's collection
Maker
Machlett Laboratories, Inc.
Site Made (City)
Springdale
Site Made (State)
Connecticut
Site Made (Country)
United States of America
Material
metal: silver
plastic: black
wood: brown
glass: clear
Inscriptions
Part label on top of valve reads, "Machlett Valve Tube Type ML-1SE Maximum Voltage 125 pk
Normal Filament Adjustment ..?.. 10 Volts"; stamped on lower inside metal tube is the number
"H50616"
Permanent Location
Storage Room 0007
0007-F2-3
Dimension Notes
Length: 44.5 cm. x Width: 22.0 cm.
Condition Remarks
Tube was dirty and dusty; the label on the top of the tube has deteriorated and parts have
flaked off
Copy Type
Original
Reference Types
Person
Book
JPG
Reference Comments
Nancy Chisholm; Bernie Ziomkiewicz; "The Trail of the Invisible Light" by E.R.N. Grigg, M.D.; CD #4
Images
Less detail

Coolidge tube housing

https://mhc.andornot.com/en/permalink/artifact438
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
995004022
Description
Early Coolidge tube housing which consists of a cylindrical bakelite tube with open ends; the ends are made of metal (one is chrome-plated); the centre of the tube has a ridge chromed metal section with a round opening which has red glass at the bottom and allows the centre of the tube to be seen.
  3 images  
Accession Number
995004022
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Radiography -- instrumentation
Description
Early Coolidge tube housing which consists of a cylindrical bakelite tube with open ends; the ends are made of metal (one is chrome-plated); the centre of the tube has a ridge chromed
metal section with a round opening which has red glass at the bottom and allows the centre of the tube to be seen.
Number Of Parts
1
Maker
Coolidge - General Electric
Site Made (City)
Milwaukee
Site Made (State)
Wisconsin
Site Made (Country)
United States of America
Material
metal: silver
plastic: black
glass: red
Inscriptions
Centre of the tube housing has maker's marks - "1 [inside circle]" G.E. symbol and the
words "Coolidge Tube"; the other mark is Victor symbol and the words "Made in U.S.A."
Permanent Location
Storage Room 0010
0010-F4-10
Dimension Notes
Length: 46.0 cm. x Width: 8.6 cm.
Condition Remarks
Tube was dirty and dusty; the chrome sections show some wear
Copy Type
Original
Reference Types
Person
Book
JPG
Reference Comments
Nancy Chisholm; Bernie Ziomkiewicz; "The Trail of the Invisible Light" by E.R.N. Grigg, M.D.; CD #4
Images
Less detail

rectifier tube

https://mhc.andornot.com/en/permalink/artifact450
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
995004034
Description
Rectifier tube which consists of a hollow cylindrical glass tube with cylindrical metal pieces within; the top of the tube is capped with a black plastic piece (cracked) from which the top of a glass tube emerges; there are also six screw holes; the bottom of the tube is capped with a black plasti…
  1 image  
Accession Number
995004034
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Radiography -- instrumentation
MM= Radiography -- tube
Description
Rectifier tube which consists of a hollow cylindrical glass tube with cylindrical metal pieces
within; the top of the tube is capped with a black plastic piece (cracked) from which the top
of a glass tube emerges; there are also six screw holes; the bottom of the tube is capped
with a black plastic section which has a screw hole in the centre and four cut holes around
this
Number Of Parts
1
Maker
Machlett Laboratories Inc.
Site Made (City)
Springdale
Site Made (State)
Connecticut
Site Made (Country)
United States of America
Material
metal: silver
glass: clear
plastic: black
Inscriptions
Manufacturer's label at bottom reads, "ML-4IU Machlett Made in U.S.A. Maximum Voltage 140
Pkv Filament Voltage 6.0 Volts"; metal piece within is stamped "H34702"
Permanent Location
Storage Room 0010
0010-F4-9
Dimension Notes
Length: 20.8 cm. x Width: 6.3 cm.
Condition Remarks
Tube was dirty and dusty; top section of plastic is cracked
Copy Type
Original
Reference Types
Person
Book
JPG
Reference Comments
Bernie Ziomkiewicz; "The Trail of the Invisible Light" by E.R.N. Grigg, MD; CD #4
Images
Less detail

rectifier tube

https://mhc.andornot.com/en/permalink/artifact451
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
995004035
Description
X-ray tube which consists of a hollow cylindrical glass tube with cylindrical metal pieces within (and a small amount of oil); the top of the tube is capped with a black plastic piece from which the top of a glass tube emerges; there are also seven screw holes, two of which have cloth-covered wires…
  1 image  
Accession Number
995004035
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Radiography -- instrumentation
MM= Radiography -- tube
Description
X-ray tube which consists of a hollow cylindrical glass tube with cylindrical metal pieces
within (and a small amount of oil); the top of the tube is capped with a black plastic piece
from which the top of a glass tube emerges; there are also seven screw holes, two of which
have cloth-covered wires attached; the bottom of the tube is capped with a black plastic
section which has a screw hole in the centre and two cut holes either side of it
Number Of Parts
1
Maker
Machlett Laboratories Inc.
Site Made (City)
Springdale
Site Made (State)
Connecticut
Site Made (Country)
United States of America
Material
metal: silver
glass: clear
plastic: black
fabric: black
Inscriptions
Manufacturer's label at bottom reads, "ML-4IU Machlett Made in U.S.A. Maximum Voltage 140
PKV Filament Voltage 6.0 Volts"; metal piece within is stamped "H67502"
Permanent Location
Storage Room 0010
0010-F4-9
Dimension Notes
Length: 20.8 cm. x Width: 6.3 cm.
Condition Remarks
Tube was dirty and dusty; glass has a residue at the bottom which clouds the surface; there
is a yellowish liquid inside the tube
Copy Type
Original
Reference Types
Person
Book
JPG
Reference Comments
Bernie Ziomkiewicz; "The Trail of the Invisible Light" by E.R.N. Grigg, MD; CD #4
Research Facts
Oil within the glass tube likely got there as a result of the tube having been immersed in oil at some point and leaking
Images
Less detail

X-ray generator tube

https://mhc.andornot.com/en/permalink/artifact452
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
995004036
Description
Large cylindrical brown glass hollow tube which widens in the centre and has cylindrical metal pieces within; the bottom of the tube has a cylindrical metal rod with a screw attachment sticking out of it; the top of the tube has a black plastic cap which has four short metal rods coming out of it a…
  1 image  
Accession Number
995004036
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Description
Large cylindrical brown glass hollow tube which widens in the centre and has cylindrical metal
pieces within; the bottom of the tube has a cylindrical metal rod with a screw attachment
sticking out of it; the top of the tube has a black plastic cap which has four short metal
rods coming out of it and four screws holding it in place
Number Of Parts
1
Maker
Machlett Laboratories Inc.
Site Made (City)
Springdale
Site Made (State)
Connecticut
Site Made (Country)
United States of America
Material
metal: silver
glass: brown
plastic: black
Inscriptions
Manufacturer's label on the glass tube reads, "Machlett CT-220"
Permanent Location
Storage Room 0010
0010-F4-10
Dimension Notes
Length: 54.2 cm. x Width: 11.5 cm.
Condition Remarks
Tube was dirty and dusty
Copy Type
Original
Reference Types
Person
Book
JPG
Reference Comments
Bernie Ziomkiewicz; Nancy Chisholm; "The Trail of the Invisible Light" by E.R.N. Grigg; CD #4
Images
Less detail
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
995004045
Description
X-ray collimator which consists of a long painted metal base which has a long projecting thin section on one side and widens out at the other (almost key-shaped); the wide end has a square hole cut into it and plates which go in both directions over top; there is a knob at the thin end which contro…
  1 image  
Accession Number
995004045
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Radiography -- instrumentation
Description
X-ray collimator which consists of a long painted metal base which has a long projecting thin
section on one side and widens out at the other (almost key-shaped); the wide end has a square
hole cut into it and plates which go in both directions over top; there is a knob at the thin
end which controls the plates
Number Of Parts
1
Maker
Keleket
Site Made (City)
Waltham
Site Made (State)
Massachusetts
Site Made (Country)
United States of America
Material
metal: silver
paint: black
plastic: black
Inscriptions
Stamped on the bottom is, "925M-1 KELEKET"
Permanent Location
Storage Room 0010
0010-F3-2
Dimension Notes
Length: 68.0 cm. x Width: 27.0 cm.
Condition Remarks
Collimator was very dirty and dusty; some paint has chipped off from the surface
Copy Type
Original
Reference Types
Person
Book
JPG
Reference Comments
Nancy Chisholm; Bernie Ziomkiewicz; "The Trail of the Invisible Light" by E.R.N. Grigg, MD; CD #2
Research Facts
Early version of an x-ray collimator; used to block and direct x-rays
Images
Less detail

intensifying screen

https://mhc.andornot.com/en/permalink/artifact462
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
995004046
Description
Intensifying x-ray screen, which consists of an outer rectangular metal frame with an inner section which is hinged at the top, has a lifting handle at the bottom and a metal bar across the middle which turns to lock the inner section into the frame; the flat painted middle piece of metal has felt …
  3 images  
Accession Number
995004046
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Radiography -- instrumentation
Description
Intensifying x-ray screen, which consists of an outer rectangular metal frame with an inner
section which is hinged at the top, has a lifting handle at the bottom and a metal bar across
the middle which turns to lock the inner section into the frame; the flat painted middle piece
of metal has felt on the inside over which is a piece of coated paper; the inner piece fits
tightly into the outer frame
Number Of Parts
1
Maker
Geo. W. Brady & Co. X-Ray Supplies
Site Made (City)
Chicago
Site Made (State)
Illinois
Site Made (Country)
United States of America
Material
metal: silver
fabric: black
paper: off-white
Inscriptions
Manufacturer's label reads, "Geo. W. Brady & Co. X-Ray Supplies Chicago, Ill."
Permanent Location
Storage Room 0010
0010-F3-5
Dimension Notes
Length: 25.2 cm. x Width: 19.8 cm. x Depth: 1.7 cm.
Condition Remarks
The screen was dirty and dusty; (2) the top surface of the screen had many shallow scratches in it from heavy use; this does not appear to be a result of its exhibit history; the metal frame is also worn from use , and there is a spot of inactive corrosion on the one short side from a fingerprint, 1.2 cm x 1.7 cm; there are smaller dark smudges from handling and use over approximately 10% of the frame; on the reverse side the exposed felt is moderately frayed; there were no signs of active corrosion; the paint on the hinges of the backing plate was worn.
Copy Type
Original
Reference Types
Person
Book
JPG
Reference Comments
Bernie Ziomkiewicz; "The Trail of the Invisible Light" by E.R.N. Grigg, MD; CD #6
Research Facts
The intensifying screen had x-ray film put inside and was then placed under the patient for
x-raying; the intensifying zinc sulfide in the screen allowed for shorter exposure times
Exhibit History
Spring 1998-Sept. 17, 2002: on exhibit in KGH Hall of Honour in "The Advent of X-rays"
Images
Less detail
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
995004049
Description
Timer which consists of a rounded black bakelite case with a flat round metal scale and timer (in seconds 0-12) pointer on the front; the top of the timer has a round white button which stops the x-ray exposure when at 0; the sides of the timer have grooves which enable it to be held; the bottom of…
  1 image  
Accession Number
995004049
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Radiography -- instrumentation
Description
Timer which consists of a rounded black bakelite case with a flat round metal scale and timer
(in seconds 0-12) pointer on the front; the top of the timer has a round white button which
stops the x-ray exposure when at 0; the sides of the timer have grooves which enable it to
be held; the bottom of the timer has a [?] cm electric cord coming out of it; the top back
of the timer has a metal attachment which allows it to be hung
Number Of Parts
1
Maker
Liebel-Florsheim Company
Site Made (City)
Cincinatti
Site Made (State)
Ohio
Site Made (Country)
United States of America
Material
metal: silver
plastic: white; black
Inscriptions
The front of the timer has a dial and scale 0-12 seconds; it also reads, "The Liebel Florsheim
Co. Patents No. 1,677,107 1,547,442"; hanging hook has the number 84779 stamped into the back
Permanent Location
Storage Room 0010
0010-F3-1
Dimension Notes
Length: 18.0 cm. x Width: 7.5 cm. x Depth: 7.0 cm.
Condition Remarks
Timer was dusty and dirty; the electric cord was not tested, but the timer will go if set
Copy Type
Original
Reference Types
Person
Book
JPG
Reference Comments
Bernie Ziomkiewicz; "The Trail of the Invisible Light" by E.R.N. Grigg MD; CD #4
Images
Less detail
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
995004050
Description
Film magazine which consists of a hollow rectangular metal box (hinged at the top) with a scale of footage remaining at the top and an open and close key at the bottom as well as a camera lens; inside are two film reels with a film on them; the lid has a threading diagram on the inside of it
  2 images  
Accession Number
995004050
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
X-Ray Film
Radiography -- instrumentation
Description
Film magazine which consists of a hollow rectangular metal box (hinged at the top) with a scale of footage remaining at the top and an open and close key at the bottom as well as a camera lens; inside are two film reels with a film on them; the lid has a threading
diagram on the inside of it
Number Of Parts
1
Maker
Picker Co.; Dupont Co.
Site Made (Country)
United States of America
Material
metal: silver
paint: green; black
film: green
Inscriptions
There is a threading diagram on the inside lid as well as a sticker which reads, "Picker part No. A-40206B"; the inside base has a sticker which reads, "Caution close sprocket film shoe
before closing cover"; the reels have "Dupont Company Made in U.S.A." stamped on them; the footage remaining scale at the top is from 0-100
Permanent Location
Storage Room 0010
0010-F3-2
Dimension Notes
Length: 21.0 cm. x Width: 12.7 cm. x Depth: 3.5 cm.
Condition Remarks
Film magazine was dusty and dirty
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Bernie Ziomkiewicz; CD #4
Images
Less detail

X-ray tube (part); Cathode filament assembly

https://mhc.andornot.com/en/permalink/artifact478
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
995004062
Description
Cathode filament assembly from an early X-ray tube, which consists of a cylindrical base which bulbs out of the bottom; the base is hollow and open at the top to show the remains of a glass tube; curled wire and two rubber (?)-covered wires leading out (one green, one black)
  2 images  
Accession Number
995004062
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
MM= Radiography -- tube
Description
Cathode filament assembly from an early X-ray tube, which consists of a cylindrical base which
bulbs out of the bottom; the base is hollow and open at the top to show the remains of a glass
tube; curled wire and two rubber (?)-covered wires leading out (one green, one black)
Number Of Parts
1
Material
metal: light grey
glass: clear
rubber (?): black; green
Permanent Location
Storage Room 0010
0010-F4-10
Dimension Notes
Width: 6.4 cm. x Depth: 7.5 cm.
Condition Remarks
The cathode filament assembly was dirty and dusty; the metal shows some corrosion; the original
glass tube has been broken and only jagged bits remain
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Nancy Chisholm; Bernie Ziomkiewicz; CD #4
Research Facts
Cathode filament assembly from an early X-ray tube; from a Coolidge tube cathode; likely goes
with the anode end (995.004.063)
Images
Less detail

X-ray tube (part); anode filament assembly

https://mhc.andornot.com/en/permalink/artifact479
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
995004063
Description
Anode filament assembly from an early X-ray tube, which consists of a funnel-shaped tube which is open at the wide end; likely copper with a tungsten insert; the open wide end reveals the inside of the tube and a cylindrical metal tube within; the closed end is heavy and diagonally slanted
  2 images  
Accession Number
995004063
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
MM= Radiography -- tube
Description
Anode filament assembly from an early X-ray tube, which consists of a funnel-shaped tube which
is open at the wide end; likely copper with a tungsten insert; the open wide end reveals the
inside of the tube and a cylindrical metal tube within; the closed end is heavy and diagonally
slanted
Number Of Parts
1
Material
metal: light grey; brown
Permanent Location
Storage Room 0010
0010-F4-10
Dimension Notes
Width: 8.2 cm. x Depth: 15.3 cm.
Condition Remarks
The anode filament assembly was dirty and dusty; there is a crust of hard black material on
the inner metal cylinder
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Bernie Ziomkiewicz; CD #4
Research Facts
Anode filament assembly from an early X-ray tube; from a Coolidge tube anode; likely goes
with the cathode end (995.004.062)
Images
Less detail
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
995004065
Description
Portable x-ray viewer which consists of two pieces of brown bookbinding cloth-covered wood (?) hinged together with gold-coloured metal hinges; the front piece has a piece of frosted grey glass set into it; the back has two cylindrical silver-coloured metal knobs coming out of it and a cloth strip …
  3 images  
Accession Number
995004065
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Radiography -- instrumentation
Description
Portable x-ray viewer which consists of two pieces of brown bookbinding cloth-covered wood (?)
hinged together with gold-coloured metal hinges; the front piece has a piece of frosted grey
glass set into it; the back has two cylindrical silver-coloured metal knobs coming out of it
and a cloth strip which snaps on and off at one end
Number Of Parts
1
Material
glass: grey
wood (?):
fabric: brown
metal: silver; yellow
Permanent Location
Storage Room 0010
0010-F3-6
Dimension Notes
Length: 27.0 cm. x Width: 29.3 cm. x Depth: 1.0 cm.
Condition Remarks
The viewer was dirty and dusty; screen appears to have had little or no use
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Burr; CD #4
Images
Less detail
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
995004066
Description
Transistor which consists of a cylindrical base which is made of copper with a black plastic coating on the outside; the inside of the base has screw threads which allow the transistor to be screwed onto something; coming out from the top of the base are three wires (4.5 cm in length)
  1 image  
Accession Number
995004066
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Radiography -- instrumentation
Description
Transistor which consists of a cylindrical base which is made of copper with a black plastic
coating on the outside; the inside of the base has screw threads which allow the transistor
to be screwed onto something; coming out from the top of the base are three wires (4.5 cm
in length)
Number Of Parts
1
Maker
CBS
Material
plastic: black
metal: brown; silver
Inscriptions
Printed on the side: "CBS 2N156"
Permanent Location
Storage Room 0010
0010-F4-10
Dimension Notes
Length: 6.6 cm. x Width: 1.3 cm.
Condition Remarks
Transistor was dirty and dusty; the wires are not straight (have been bent)
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Bernie Ziomkiewicz; CD #4
Images
Less detail

electric motor

https://mhc.andornot.com/en/permalink/artifact485
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
995004069 a-b
Description
Small electric motor which consists of rectangular laminated steel plates (31) with a roll of wire around a black plastic casing at the front and a brass section at the back which contains round moving parts; the back has a piece of coated wood screwed on; the bottom has two strips of coated cloth …
  2 images  
Accession Number
995004069 a-b
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Radiography -- instrumentation
MM= Radiography -- machine
Description
Small electric motor which consists of rectangular laminated steel plates (31) with a roll of
wire around a black plastic casing at the front and a brass section at the back which contains
round moving parts; the back has a piece of coated wood screwed on; the bottom has two strips
of coated cloth on the brass section and two wires ( one unattached) coming from the wire roll
Number Of Parts
2
Part Names
a - Size: Length 7.3 cm. x Width 7.4 cm. x Depth 4.3 cm.
b - Size:
Maker
Barber-Colman Co.
Site Made (City)
Rockford
Site Made (State)
Illinois
Site Made (Country)
United States of America
Material
metal: silver; grey; yellow
plastic: black
wood: brown
fabric: brown
Inscriptions
Wood at back marked "CW C CCW (Clockwise and Counter clock-wise)"; steel plates stamped
"466" and "61722"; plastic casing reads: "Barber Colman Co. Rockford Ill."
Permanent Location
Storage Room 0010
0010-F3-1
Condition Remarks
Motor was very dirty and dusty; one of the wires has broken off; there is also a chip missing
from the plastic
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Bernie Ziomkiewicz; CD #2
Research Facts
Possibly a clock motor
Images
Less detail
Collection
Kingston General Hospital School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
000019001 a-d
Description
A Kodak brand 35 mm (a) film reel on plastic spool in a (b-c) two part yellow locking storage container (d) with removable blue plastic disk over one of the locking corners.
  2 images  
Accession Number
000019001 a-d
Collection
Kingston General Hospital School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
X-Rays -- audiovisual aids
Radiology
Description
A Kodak brand 35 mm (a) film reel on plastic spool in a (b-c) two part yellow locking storage container (d) with removable blue plastic disk over one of the locking corners.
Number Of Parts
4
Part Names
a - reel - Size: Depth 2.1cm x Diam. 31.0 cm
b - top - Size: Length 33.5 cm x Width 33.5 cm x Depth 3.4 cm
c - bottom - Size: Length 33.5 cm x Width 33.5 cm x Depth 3.0 cm
d - disk - Size: Width 0.2 mm x Diam. 3.3 cm
Provenance
School of X-Ray at Kingston General Hospital
Maker
Eastman Kodak Company
Site Made (City)
Rochester
Site Made (State)
New York
Site Made (Country)
United States of America
Material
plastic: yellow, dark grey, blue, white, clear
metal: silver
paper: cream
ink: black, red
Inscriptions
Embossed on storage canister: "PROPERTY OF EASTMAN KODAK COMPANY // ROCHESTER, NEW YORK"; Hand printed on top of cannister. "INSIDE // STORY // MEDICAL"; Embossed on film reel : "PROPERTY // OF // NBC // PLASTIC REEL CORPORATION OF AMERICA"; handwritten on top of container: "P. C. L."
Permanent Location
Storage Room 0010
0010-C8-5
Condition Remarks
Container shows minor wear scratches along edges.
Copy Type
Original
Reference Types
Person
Reference Comments
Richard Woods (donor)
Research Facts
Donor indicated this was a documentary on X-Ray.
Images
Less detail
Collection
University Health Network - Academy of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
81.15.2
Description
Note: item is missing
Accession Number
81.15.2
Collection
University Health Network - Academy of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Art
Description
Note: item is missing
Provenance
Acquired from the Academy of Medicine.
Temporary Location
Item is missing.
Copy Type
Original
Less detail
Collection
University Health Network - Academy of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
2000.1.3
Description
Note: item is missing.
  1 image  
Accession Number
2000.1.3
Collection
University Health Network - Academy of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Radiography, Diagnostic Imaging
Description
Note: item is missing.
Provenance
Acquired from the Academy of Medicine.
Permanent Location
Storage Room 0007
0007-E2-3
Temporary Location
Item is missing.
Copy Type
Original
Reference Types
JPG
Reference Comments
CD #UHN
Images
Less detail
Collection
University Health Network - Academy of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
2000.1.8
  1 image  
Accession Number
2000.1.8
Collection
University Health Network - Academy of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Radiography, Diagnostic Imaging
Provenance
Acquired from the Academy of Medicine.
Copy Type
Original
Reference Types
JPG
Reference Comments
CD #UHN
Images
Less detail

Coolidge transformer

https://mhc.andornot.com/en/permalink/artifact429
Dates
1890
circa 1890
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
995004013
Description
Coolidge transformer which consists of a metal base with 28 screw holes, indicating it was attached to something at some point; the middle of the base has a hole cut out of it which measures 8 cm in diameter and is surrounded with cork; onto the base is attached two vertical bars with a cloth-cover…
  1 image  
Accession Number
995004013
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Radiography -- instrumentation
Radiotherapy
Description
Coolidge transformer which consists of a metal base with 28 screw holes, indicating it was
attached to something at some point; the middle of the base has a hole cut out of it which
measures 8 cm in diameter and is surrounded with cork; onto the base is attached two vertical
bars with a cloth-covered vertical bar at the top and another halfway down; the second vertical
bar has a metal cylinder on it with a cloth-covered attachment in the centre; there
are wires leading out of this attachment
Number Of Parts
1
Maker
The Kelley Koett Mfg. Co. Inc.
Site Made (City)
Covington
Site Made (State)
Kentucky
Site Made (Country)
United States of America
Dates
1890
circa 1890
Date Remarks
1890-1900
Material
metal: dark grey
fabric: brown
paint: black
cork: beige
Inscriptions
Manufacturer's label on bottom reads, "Coolidge Transformer Volts 120 Cycles 60 Type J The
Kelley Koett Mfg. Co. Inc."
Permanent Location
Storage Room 0007
0007-F2-2
Dimension Notes
Length: 27.0 cm. x Width: 21.0 cm. x Depth: 24.0 cm.
Condition Remarks
Transformer was very dirty and dusty; the cloth tape is worn in several spots; the paint on
the base is chipped in several spots; the electric wires are cracked in 5 places
Copy Type
Original
Reference Types
Person
Book
JPG
Reference Comments
Nancy Chisholm; "The Trail of the Invisible Light" by E.R.N. Grigg, M.D.; Bernie Ziomkiewicz; CD #4
Research Facts
Power unit for a filament
Images
Less detail

102 records – page 1 of 6.