Skip header and navigation

Refine By

6 records – page 1 of 1.

Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
995004049
Description
Timer which consists of a rounded black bakelite case with a flat round metal scale and timer (in seconds 0-12) pointer on the front; the top of the timer has a round white button which stops the x-ray exposure when at 0; the sides of the timer have grooves which enable it to be held; the bottom of…
  1 image  
Accession Number
995004049
Collection
Queen's University School of X-Ray Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Radiography -- instrumentation
Description
Timer which consists of a rounded black bakelite case with a flat round metal scale and timer
(in seconds 0-12) pointer on the front; the top of the timer has a round white button which
stops the x-ray exposure when at 0; the sides of the timer have grooves which enable it to
be held; the bottom of the timer has a [?] cm electric cord coming out of it; the top back
of the timer has a metal attachment which allows it to be hung
Number Of Parts
1
Maker
Liebel-Florsheim Company
Site Made (City)
Cincinatti
Site Made (State)
Ohio
Site Made (Country)
United States of America
Material
metal: silver
plastic: white; black
Inscriptions
The front of the timer has a dial and scale 0-12 seconds; it also reads, "The Liebel Florsheim
Co. Patents No. 1,677,107 1,547,442"; hanging hook has the number 84779 stamped into the back
Permanent Location
Storage Room 0010
0010-F3-1
Dimension Notes
Length: 18.0 cm. x Width: 7.5 cm. x Depth: 7.0 cm.
Condition Remarks
Timer was dusty and dirty; the electric cord was not tested, but the timer will go if set
Copy Type
Original
Reference Types
Person
Book
JPG
Reference Comments
Bernie Ziomkiewicz; "The Trail of the Invisible Light" by E.R.N. Grigg MD; CD #4
Images
Less detail

Bucky diaphragm motor oil

https://mhc.andornot.com/en/permalink/artifact11450
Dates
1930
1950
1930-1950
Collection
Dr. Charles H. Bird / Dr. Godfrey Bird Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
997037591
Description
Glass bottle of Bucky diaphragm motor oil with screw cap with paper label.
  1 image  
Accession Number
997037591
Collection
Dr. Charles H. Bird / Dr. Godfrey Bird Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Radiography -- instrumentation
Description
Glass bottle of Bucky diaphragm motor oil with screw cap with paper label.
Number Of Parts
1
Provenance
Dr. H. Godfrey Bird
Maker
General Electric X-Ray Corporation
Site Made (Country)
United States of America
Dates
1930
1950
1930-1950
Date Remarks
Date determined by font style
Material
glass: clear
metal: brown
paper: cream
ink: red
Inscriptions
Printed on paper label: "BUCKY DIAPHRAGM // MOTOR OIL"; embossed in glass on back neck: "8" in U-shaped wreath.
Permanent Location
Storage Room 0010
0010-A4-7 Box 5 Row A
Length
18.2 cm
Width
7.0 cm
Depth
4.3 cm
Unit Of Measure
centimeters
Copy Type
Original
Research Facts
A bottle of oil for an X-ray machine.
Images
Less detail
Dates
1940
1949
circa 1940-1949
Collection
John Corson Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
008028001 a-c
Description
Black and brown fabric covered x-ray apron with two removable adjustable shoulder straps attached by metal clips.
  2 images  
Accession Number
008028001 a-c
Collection
John Corson Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Protective Clothing
Textiles
Radiology -- instrumentation
Description
Black and brown fabric covered x-ray apron with two removable adjustable shoulder straps attached by metal clips.
Number Of Parts
3
Part Names
a - x-ray apron - Size: Length 90.1 cm x Width 63.1 cm x Depth 0.5 cm
b - left shoulder strap - Size: Length 70.5 cm x Width 3.4 cm x Depth 1.7 cm
c - right shoulder strap - Size: Length 66.8 cm x Width 3.9 cm x Depth 1.3 cm
Provenance
Owned by John Corson's father.
Maker
General Electric X-Ray Corporation
Dates
1940
1949
circa 1940-1949
Date Remarks
Based on appraisal
Material
fabric: black, brown
metal: black, silver
plastic: black
ink: yellow
Inscriptions
Stamped on front of apron: "XRP APRON // MANUFACTURED FOR // GENERAL ELECTRIC // X-RAY CORPORATION // THIS APRON HAS X-RAY PROTECTION // EQUAL TO 0.3 MM. LEAD UP TO 8.5 KVI"
Permanent Location
Storage Room 0007
0007-D2-3
Condition Remarks
Minor stains around perimiter of apron; minor rust on strap buckles
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
John Corson; CD #4
Research Facts
Dr. Corson was a graduate of University of Toronto School of Medicine, Class of 1941; operated his general practice in his Scarborough home from 1947-1983.
Images
Less detail
Dates
1940
1949
circa 1940-1949
Collection
John Corson Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
008028003
Description
Black rectangular lead plate.
  2 images  
Accession Number
008028003
Collection
John Corson Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
X-Ray Film
Radiography -- instrumentation
Description
Black rectangular lead plate.
Number Of Parts
1
Provenance
Owned by John Corson's father.
Maker
General Electric X-Ray Corporation
Dates
1940
1949
circa 1940-1949
Date Remarks
Based on appraisal
Material
metal: black
Permanent Location
Storage Room 0007
0007-D2-3
Dimension Notes
Length 35.5 cm x Width 21.2 cm x Depth 0.5 cm
Condition Remarks
Minor scratches
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
John Corson; CD #4
Research Facts
Dr. Corson was a graduate of University of Toronto School of Medicine, Class of 1941; operated his general practise in his Scarborough home from 1947-1983.
Images
Less detail
Dates
1940
1950
circa 1940-1950
Collection
John Corson Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
008028009 a-b
Description
Pair of lead-lined brown leather five fingered x-ray gloves with a long cuff and flared bottom; interior lined with cream woven cotton cloth; manufacturer's information inside each glove; pair consists of a right (a) and left glove (b).
  4 images  
Accession Number
008028009 a-b
Collection
John Corson Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Radiography -- instrumentation
Protective Clothing
Description
Pair of lead-lined brown leather five fingered x-ray gloves with a long cuff and flared bottom; interior lined with cream woven cotton cloth; manufacturer's information inside each glove; pair consists of a right (a) and left glove (b).
Number Of Parts
2
Part Names
a - right - Length 38.5 cm x Width 21.0 cm x Depth 2.8 cm
b - left - Length 38.5 cm x Width 21.0 cm x Depth 3.0 cm
Provenance
Owned by donor's father at his medical office.
Maker
General Electric X-Ray Corporation
Dates
1940
1950
circa 1940-1950
Date Remarks
Date based on donor's remarks and appraisal
Material
leather: brown
fabric: cream
ink: black
Inscriptions
Stamped onto the inside of each glove: "GENERAL ELECTRIC // X-RAY CORPORATION // XRP // [Illeg.] U.S. PAT OFFICE // [Illeg.] 4-5 [Illeg.] 9"
Permanent Location
Storage Room 0007
0007-D2-2
Condition Remarks
Minor red rot along edges, shows wear and creases worn into fingers
Copy Type
Original
Reference Types
Internet
Reference Comments
"General Electric" website; "e-radiography" website
Research Facts
General Electric began in the 1890's and was established by Thomas Alva Edison by bringing his various businesses together and creating the General Electric Company. Lead lined x-ray equipment was and still is used to protect the wearer from radiation.
Images
Less detail
Dates
1950
1965
circa 1950-1965
Collection
Dr. Charles H. Bird / Dr. Godfrey Bird Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
Accession Number
997037174 a-b
Description
X-ray gloves that are five-fingered, fifteen inch leather-covered gloves with a flared bottom and greater length to cuff for increased wearer protection; the interior of the gloves has two layers of lead rubber that extends over all surfaces; the interior is lined with an off-white woven cotton clo…
  1 image  
Accession Number
997037174 a-b
Collection
Dr. Charles H. Bird / Dr. Godfrey Bird Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnostic Radiology
MeSH Heading
Radiography -- instrumentation
Protective Clothing
Description
X-ray gloves that are five-fingered, fifteen inch leather-covered gloves with a flared bottom and greater length to cuff for increased wearer protection; the interior of the gloves has two layers of lead rubber that extends over all surfaces; the interior is lined with an off-white woven cotton cloth; each glove has three decorative raised ribs and stitching along each side and every finger
Number Of Parts
2
Part Names
a - left
b - right
Provenance
Used either by Dr. C.H. Bird or by Dr. Godfrey Bird, of Gananoque, Ont.
Maker
General Electric X-Ray Corporation
Site Made (Country)
United States of America
Dates
1950
1965
circa 1950-1965
Material
leather: brown
rubber:
Inscriptions
Printed on inside wrist of both gloves: "GENERAL ELECTRIC // X-RAY CORPORATION // X R P // TRADEMARK REGISTERED U.S. PAT. OFFICE // MADE IN U.S.A."
Permanent Location
Storage Room 0010
0010-F3-3
Dimension Notes
a-b - glove - Length 38.1 cm x Width 16.5 cm x Depth 2.1 cm
Condition Remarks
Gloves show extensive scuffs and scratches; leather is stained on palms of gloves, with some fraying along seams; #2: leather is very stiff
Copy Type
Original
Reference Types
Book
Reference Comments
"Catalog C-30," American Hospital Supply, Toronto, ca 1964 (similar to item 29510)
Images
Less detail

6 records – page 1 of 1.