University Health Network - Academy of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
Accession Number
1971.2.7 a-e
Description
Three metal bougies (male urethral instruments) (d-e) with a cylindrical wooden case and lid (a,b); the bougies on slightly curved probes, tear-shaped ends; French scale No. 8-40.
Three metal bougies (male urethral instruments) (d-e) with a cylindrical wooden case and lid (a,b); the bougies on slightly curved probes, tear-shaped ends; French scale No. 8-40.
Number Of Parts
5
Part Names
a - case bottom - Size: Length 24.0 cm x Diam. 3.0 cm
b - case top - Size: Length 24.0 cm x Diam. 3.0 cm
c - bougie, size 20 - Size: Length 21.5 cm
d - bougie, size 22 - Size: Length 21.5 cm
e - bougie, size 24 - Size: Length 21.5 cm
Provenance
Acquired from the Academy of Medicine; source: Dr. G.S. Barker of Brantford, Ont.
Dates
1900
1976
circa 1900-1976
Date Remarks
Original record had "20c."
Material
metal: silver
wood: brown
Permanent Location
Storage Room 0010
0010-E7-12
Condition Remarks
Case: label torn; marked and dirty
Copy Type
Original
Reference Types
Book
JPG
Reference Comments
Kny-Scheerer catalogue, 1915, p. 4054 (similar to item #D/-2676); CD #UHN
University Health Network - Academy of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
Accession Number
1983.4.3
Description
A length of amber tubing with a plastic plug at one end; left in the original sealed package to protect rubber from deteriorating due to exposure to air.
A length of amber tubing with a plastic plug at one end; left in the original sealed package to protect rubber from deteriorating due to exposure to air.
Number Of Parts
1
Provenance
Acquired from the Academy of Medicine; source: Mr. J. D. Tanner.
University Health Network - Academy of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
Accession Number
1984.14.10 a-b
Description
Two glass catheters; on end angled at about 45° and with two holes, one towards the tip and the other at the bend; there is another similar bend, but in the opposite direction, about 1/3 of the way from the other end.
Two glass catheters; on end angled at about 45° and with two holes, one towards the tip and the other at the bend; there is another similar bend, but in the opposite direction, about 1/3 of the way from the other end.
Number Of Parts
2
Part Names
a - catheter - Size: Length 16.0 cm
b - catheter - Size: Length 16.0 cm
Provenance
Acquired from the Academy of Medicine; source: Dr. W.J. Wilson; used by his father, Dr. J.P WIlson.
Dates
1900
1999
1900-1999
Date Remarks
Original record had "20c."
Material
glass: clear
Permanent Location
Storage Room 0010
0010-E8-2
Copy Type
Original
Reference Types
JPG
Reference Comments
CD #UHN
Research Facts
Dr. J.P. Wilson graduated from U of T in 1911 and practised in Richmond Hill 1919-1967.
Male urethral dilator set consisting of a black leather rectangular case with clasp closure lid (a); brown leather interior holds ten metal dilators, sized on the French scale: 32 (b), 30 (c), 28 (d), 26 (e), 24 (f), 22 (g), 20 (h), 18 (i), 12 (j), 10 (k); dilators have flat ends with rounded sides…
Male urethral dilator set consisting of a black leather rectangular case with clasp closure lid (a); brown leather interior holds ten metal dilators, sized on the French scale: 32 (b), 30 (c), 28 (d), 26 (e), 24 (f), 22 (g), 20 (h), 18 (i), 12 (j), 10 (k); dilators have flat ends with rounded sides which taper into a cylindrical shape with a rounded end; these ends curve upward
Number Of Parts
11
Part Names
a - case - Size: Length 36.0 cm x Width 14.9 cm x Depth 4.0 cm
b - dilator - Size: Length 27.5 cm x Diam. 1.6 cm
c - dilator - Size: Length 27.5 cm x Diam. 1.0 cm
d - dilator - Size: Length 27.5 cm x Diam. 0.93 cm
e - dilator - Size: Length 27.0 cm x Diam. 0.86 cm
f - dilator - Size: Length 27.0 cm x Diam. 0.8 cm
g - dilator - Size: Length 26.5 cm x Diam. 0.73 cm
h - dilator - Size: Length 26.5 cm x Diam. 0.66 cm
i - dilator - Size: Length 26.5 cm x Diam. 0.4 cm
j - dilator - Size: Length 24.0 cm x Diam. 0.33 cm
k - dilator - Size: Length 24.0 cm x Diam. 0.3 cm
Provenance
Donated by Dean Barry Smith, Faculty of Medicine, Queen's University
(b) Stamped on end: "AM-S-T-A // 32 // STANDARD"; (c) stamped on end: "A-S-T-A // 30 // STANDARD"; (d) stamped on end: "A-S-T-A // 28 // STANDARD"; (e) stamped on end: "A-S-T-A // 26 // STANDARD"; (f) stamped on end: "A-S-T-A // 24 // STANDARD"; (g) stamped on end: "A-S-T-A // 22 // STANDARD"; (h) stamped on end: "A-S-T-A // 20 // STANDARD"; (i) stamped on end: "A-S-T-A // 18 // STANDARD"; (j) stamped on end: "A-S-T-A // 12 // STANDARD"; (k) stamped on end: "A-S-T-A // 10 // STANDARD"
Permanent Location
Storage Room 0010
0010-E7-14
Condition Remarks
Case is slightly scuffed, especially at corners; leather inside case is faded in parts; two dilators are missing
Copy Type
Original
Reference Types
Person
Document
Book
JPG
Reference Comments
"Kingston General Hospital: A Social and Institutional History", Margaret Angus, 1973, p. 113, 165; "Illustrations of Surgical Instruments of Superior Quality 21st ed", Kny-Scheerer Co, ca. 1915, p. 4056 (similar to model #D/-2744); "Pilling Instruments and Equipment for Surgeons and Hospitals", George P. Pilling & Son, 1932, p. 279 (similar to model #P19372); "Sklar Surgical Instruments, Suction & Pressure Apparatus", Sklar Instruments, 1967, p. 296; CD #8
Research Facts
Label inside case states the object was donated in 1985 by the wife of the late surgeon Dr. W. Stuart Houston; a senior intern at the Kingston General Hospital in 1926, he retired from an Attending position in General Surgery in 1960; he also taught courses at Queen's University
Exhibit History
On exhibit in the Friend-Vandewater Gallery in Botterell Hall, Queen's University; removed January 27, 2010
Catheter guide consists of a heavy-gauge steel wire, bent into a roughly pentagonal shape at one end for a handle; curved at the other end with a rounded tip; has been bent again above the handle.
Catheter guide consists of a heavy-gauge steel wire, bent into a roughly pentagonal shape at one end for a handle; curved at the other end with a rounded tip; has been bent again above the handle.
Number Of Parts
1
Provenance
Dr. James Howard Walmsey, graduated Queen’s University Faculty of Medicine Class of 1915.
Wire stylet, straight, smooth, flexible fine wire with a loop at one end; fits inside a sleeve.
Number Of Parts
1
Provenance
Acquired from the Academy of Medicine; source: Mrs. Leslie W. Black via Dr. A. D. Kelly at the Ontario Medical Association; instruments from the practice of Dr. Malcolm C. Black, Mrs. Black's father-in-law.
Dates
1920
1950
circa 1930-1950
Material
metal: silver
Permanent Location
Storage Room 0010
0010-E8-2
Dimension Notes
Length 34.0 cm
Copy Type
Original
Research Facts
Surgical and diagnostic instruments ca 1890-1900 from the practice of Dr. Malcolm C. Black of Hespeler, Ont.
On disk-like handle, in logo form: a large "M" with a "c" above it and "TO" below; to its left is "IN" and to its right is "SH"; below this is "CHICAGO".
Queen's University Archives / Kingston General Hospital Archives Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
Accession Number
992056001
Description
Cream plastic sizing gauge has sizes ranging from # 1-33; samples of colour-coded handle colours are listed (4F, 5F, 6F, 7F, 8F); measurements are listed in millimeters: (0-100); a French scale (0-40) on back; sizes for lamps & cutting loops listed on back.
Cream plastic sizing gauge has sizes ranging from # 1-33; samples of colour-coded handle colours are listed (4F, 5F, 6F, 7F, 8F); measurements are listed in millimeters: (0-100); a French scale (0-40) on back; sizes for lamps & cutting loops listed on back.
A Brown-Buerger cystoscope consisting of a custom-made walnut case, hinged along one side, an examining telescope at top, an obdurator, a double catheterizing telescope, a concave and convex sheath, cleaning rod, brown conducting cord at bottom and assorted rubber tips, a connecting nipple, cathete…
A Brown-Buerger cystoscope consisting of a custom-made walnut case, hinged along one side, an examining telescope at top, an obdurator, a double catheterizing telescope, a concave and convex sheath, cleaning rod, brown conducting cord at bottom and assorted rubber tips, a connecting nipple, catheter clip and light bulb case in case with sliding lid at top left.
Number Of Parts
21
Part Names
a - walnut case - Size: Length 34.0 cm. x Width 15.6 cm. x Depth 6.0 cm.
b - sliding metal lid for inside case - Size: Length 20.7 cm. x Width 2.9 cm. x Depth 0.1 cm.
c - examining telescope - Size: Length 26.5 cm. x Width 3.5 cm. x Depth 0.4 cm.
d - concave sheath - Size: Length 24.5 cm. x Width 5.1 cm. x Depth 0.5 cm.
e - obdurator - Size: Length 25.7 cm. x Width 1.3 cm. x Depth 0.4 cm.
f - double catheterizing telescope - Size: Length 29.0 cm. x Width 3.5 cm. x Depth 0.4 cm.
g - convex sheath - Size: Length 24.5 cm. x Width 5.1 cm. x Depth 0.5 cm.
h - conductor cord - Size: Length 197.8 cm. x Width 11.0 cm. x Depth 1.1 cm.
i - cleaning hook - Size: Length 26.5 cm. x Width 1.8 cm. x Depth 0.3 cm.
j - plastic lightbulb case - outer - Size: Length 7.2 cm. x Width 1.6 cm. x Depth 1.1 cm.
k - plastic lightbulb case - inner - Size: Length 7.0 cm. x Width 1.2 cm. x Depth 0.7 cm.
l - catheter clip - Size: Length 4.6 cm. x Width 1.5 cm. x Depth 0.6 cm.
m - connecting nipple - Size: Length 2.3 cm. x Width 1.0 cm.
n-o - rubber nipple, black (x2) - Size: Length 1.2 cm. x Width 0.9 cm.
p-q - rubber nipple, ochre (x2) - Size: Length 1.7 cm. x Width 0.7 cm.
r-s - rubber nipple, black (small) (x2) - Size: Length 1.3 cm. x Width 0.8 cm.
t-u - rubber nipple, ochre (small) (x2) - Size: Length 1.2 cm. x Width 0.8 cm.
Provenance
Used by Dr. J.A. Low at the Bladder Function Clinic, Kingston General Hospital, from 1965 to 1970
(a) sticker on case reads, "INGRAM & BELL // LIMITED // TORONTO // MONTREAL - WINNIPEG - CALGARY VANCOUVER"; nameplate reads, "BROWN-BUERGER // CYSTOSCOPE // OCCASIONALLY GREASE CONE OF TELESCOPE TO PREVENT LEAKAGE // AND ASSURE SMOOTH ACTION OF LOCK. TO RENEW LAMP, UNSCREW // LAMP CHAMBER CAP USING RUBBER TIP AS ILLUSTRATED. // THE CORRECT LAMP FOR // THIS INSTRUMENT IS: // A . C . M . I . NO 49L // CYSTOSCOPE // RUBBER TIP // GREASE THREADS BEFORE REPLACING TO EFFECTIVELY SEAL LAMP // CHAMBER AGAINST ADMISSION OF MOISTURE. TO AVOID DAMAGE AND EXPENSIVE REPAIRS, USE GENUINE LAMPS WHICH ARE STAMPED "A . C . M . I" // FOR YOUR PROTECTION. // AMERICAN CYSTOSCOPE MAKERS, INC // DESIGNERS AND SOLE PRODUCES OF WAPPLER AND ACMI INSTRUMENTS SINCE 1900 // NEW YORK, U.S.A."; (lock): "PRESTO LOCK // CO"; (b) "AMERICAN CYSTOSCOPE MAKERS, INC. // NEW YORK, N.Y. // WAPPLER A . C . M . I . TRADE MARK DESIGNERS AND SOLE PRODUCERS OF WAPPLER AND A.C.M.I. INSTRUMENTS SINCE 1900"; (c) "AMERICAN CYSTOSCOPE // MAKERS, INC., N.Y. // MADE IN U.S.A. // 188417"; (d) "AMERICAN CYSTOSCOPE // MAKERS, INC. N.Y. // MADE IN U.S.A. // LAMP NO 49L // 16F."; (e) "A.C.M.I. // 11 // 16FR"; (f) "AMERICAN CYSTOSCOPE // MAKERS, INC. N.Y. // MADE IN U.S.A. // 186246 // 16F" - "LID UP" - "LID UP"; (g) "AMERICAN CYSTOSCOPE // MAKERS, INC. N.Y. // MADE IN U.S.A. // LAMP NO 49L // 16F"; (h) "ACMI [4X]"; (j) in script, "AMERICAN // CYSTOSCOPE // MAKERS, INC.."; (m) "B-D"
Permanent Location
Storage Room 0010
0010-E7-9
Condition Remarks
(a) surface varnish has flaked off on 20% of top and bottom surfaces; interior rim is also worn and surface around central swinging arm; (c) good condition, small signs of wear around male cone and lock pins; (d) rust visible in conical portion of head; metal plating worn off to expose brasscoloured base metal around flange; padding around lamp looks brittle and deteriorated; (e) metal surface is mottled; shiny areas of metal have given way to dull areas over 50-60% of surface; (f) normal signs of wear around male cone and lock pins; (g) rust visible in conical portion of head; metal plating worn off to expose brass-coloured base metal around flange; padding around lamp looks brittle and has deteriorated around top of lamp; (h) greenish accretion under clip of rotating contacts; white powdery accretion on black plastic head where it attaches to metal tongue; black marks on arm of left plug; (i) same mottled surface as obdurator (e); shiny areas give way to dull areas; (b) surface accretion next to trade mark at word "MARK"; some slight discolouration of surface on black surface under "CAN" of "AMERICAN"; some white specks (chips?) on black surface on reverse; (l) surface speckles of black and brown; very small and minimal number; (o-u) dusty
Copy Type
Original
Reference Types
Person
Book
Reference Comments
"Urological and Allied Diagnostic Instruments and High Frequency Equipment" by American Cystoscope Makers, Inc., pp. 30-31, 38, 146; Dr. James A. Low
Research Facts
Cystoscopes were developed in Europe in the 1870's; ACMI began the American manufacture of cystoscopes in 1908; please see photocopies of instruments; used for examining bladders, urethra, inserting catheters; 16F size most commonly used
A Brown-Buerger cystoscope consisting of a custom-made walnut case, hinged along one side, an examining telescope with grey eyepiece, a convex sheath with curved beak, a double catheterizing telescope with black eyepiece, an obdurator, a brown rubber conducting cord at the bottom of the case with t…
A Brown-Buerger cystoscope consisting of a custom-made walnut case, hinged along one side, an examining telescope with grey eyepiece, a convex sheath with curved beak, a double catheterizing telescope with black eyepiece, an obdurator, a brown rubber conducting cord at the bottom of the case with two plugs and rotating clip; an interior case with sliding metal lid located at top left corner contains a small silver metal jar of yellow grease, four ochre and four black rubber nipples, a catheter clip, and a connecting nipple.
Number Of Parts
19
Part Names
a - walnut case - Size: Length 37.4 cm. x Width 17.7 cm. x Depth 3.5 cm.
b - sliding metal lid for inside case - Size: Length 20.7 cm. x Width 2.9 cm. x Depth 1.0 mm.
c - double catheterizing telescope - Size: Length 28.9 cm. x Width 4.2 cm. x Depth 1.1 cm.
d - obdurator - Size: Length 25.7 cm. x Width 1.6 cm. x Depth 2.0 mm.
e - examining telescope - Size: Length 26.6 cm. x Width 3.2 cm. x Depth 4.0 mm.
f - convex sheath - Size: Length 24.5 cm. x Width 4.9 cm. x Depth 6.0 mm.
g - conducting cord - Size: Length 199.2 cm. x Width 1.0 cm.
h - cleaning hook - Size: Length 26.4 cm. x Width 1.3 cm. x Depth 3.0 mm.
i - catheter clip - Size: Length 26.5 cm. x Width 1.8 cm. x Depth 3.0 mm.
j - plastic lightbulb case - outer - Size: Length 7.2 cm. x Width 1.6 cm. x Depth 1.1 cm.
k - plastic lightbulb case - inner - Size: Length 7.0 cm. x Width 1.2 cm. x Depth 7.0 mm.
l - catheter clip - Size: Length 4.6 cm. x Width 1.5 cm. x Depth 6.0 mm.
j - connecting nipple - Size: Length 2.3 cm. x Width 1.0 cm.
k - grease jar - lid - Size: x Diameter8.1 cm.
l - grease jar - Size: x Diameter8.1 cm.
m-n - rubber nipple, black (x2) - Size: Length 1.7 cm. x Width 9.0 mm.
o-p - rubber nipple, ochre (x2) - Size: Length 1.7 cm. x Width 8.0 mm.
q-r - rubber nipple, black (small) (x2) - Size: Length 1.3 cm. x Width 8.0 mm.
s-t - rubber nipple, ochre (small) (x2) - Size: Length 1.2 cm. x Width 8.0 mm.
Provenance
Used by Dr. J. A. Low at the Bladder Function Clinic, Kingston General Hospital, from 1965 to 1970.
(a) sticker on interior of case reads, "INGRAM & BELL // LIMITED // TORONTO // MONTREAL - WINNIPEG CALGARY - VANCOUVER"; nameplate reads, "BROWN-BUERGER // CYSTOSCOPE // OCCASIONALLY GREASE CONE OF TELESCOPE TO PREVENT LEAKAGE // AND ASSURE SMOOTH ACTION OF LOCK. TO RENEW LAMP, UNSCREW // LAMP CHAMBER CAP USING RUBBER TIP AS ILLUSTRATED. // THE CORRECT LAMP FOR // THIS INSTRUMENT IS: // A.C.M.I. NO 49L // CYSTOSCOPE // RUBBER TIP // GREASE THREADS BEFORE REPLACING TO EFFECTIVELY SEAL LAMP // CHAMBER AGAINST ADMISSION OF MOISTURE. TO AVOID DAMAGE AND EXPENSIVE REPAIRS, USE GENUINE LAMPS WHICH ARE STAMPED "A . C . M . I" // FOR YOUR PROTECTION. // AMERICAN CYSTOSCOPE MAKERS, INC // DESIGNERS AND SOLE PRODUCES OF WAPPLER AND ACMI INSTRUMENTS SINCE 1900 // NEW YORK, U.S.A."; (lock): "PRESTO LOCK // CO"; (b) "AMERICAN CYSTOSCOPE MAKERS, INC. // NEW YORK, N.Y. // WAPPLER A . C . M . I . TRADE MARK DESIGNERS AND SOLE PRODUCERS OF WAPPLER AND A.C.M.I. INSTRUMENTS SINCE 1900"; (e) "16F" "AMERICAN CYSTOSCOPE // MAKERS, INC., N.Y. // MADE IN U.S.A. // 188415"; (c) "AMERICAN CYSTOSCOPE // MAKERS, INC. N.Y. // MADE IN U.S.A. // 176603" "LID UP" (2x) "16F"; (d) "A.C.M.I. // 11 // 16FR"; (f) "LAMP NO 49L // 16F // AMERICAN CYSTOSCOPE MAKERS, INC. N.Y. // MADE IN U.S.A."; (g) "ACMI" (4x); (k) "A.C.M.I. // GREASE"; (i) "A.C. M.I."; (j) "B-D"
Permanent Location
Storage Room 0010
0010-E7-9
Condition Remarks
(a) gouging scrapes on lid surface; longest is 9 cm; similar condition along bottom surface; largest gouge located 5 cm from left side and 1 cm from front edge; interior in good condition; one scrape on edge of central block used to house instruments; 8 spots of shiny clear accretions (glue?) on bottom inside surface; (c) one spot of corrosion 3 mm left of "16F"; dark green deposits (cleaning solution?) on lock pins; slight corrosion around base of telescope and around the heads of the
catheter guides; SHEATH FOR THIS TELESCOPE, LIKELY CONCAVE, IS MISSING; (d) opaque white residue on lock pins; green substance also evident in same location; (e) corrosion around base of telescope; green substance located on lock pins; one scrape on telescopic tip; (f) excellent condition with the exception of green substance deposits on lock lever base and on interior of lock lever (possibly grease?); (g) green deposits around base of rotating contact
Copy Type
Original
Reference Types
Person
Book
Reference Comments
"Urological and Allied Diagnostic Instruments and High Frequency Equipment" by American Cystoscope Makers, Inc., pp. 30-31, 38, 146; Dr. James A. Low
Research Facts
Cystoscopes were developed in Europe in the 1870's; ACMI began the American manufacture of cystoscopes in 1908; please see photocopies of instruments; used for examining bladders, urethra, inserting catheters; 16F (French) size most commonly used
A Brown-Buerger cystoscope consisting of a custom-made walnut case, hinged along one side, an examining telescope, a convex sheath with curved beak, a double catheterizing telescope with two catheter heads (no rubber nipples), an obdurator with a tapered conical head; an interior case with sliding …
A Brown-Buerger cystoscope consisting of a custom-made walnut case, hinged along one side, an examining telescope, a convex sheath with curved beak, a double catheterizing telescope with two catheter heads (no rubber nipples), an obdurator with a tapered conical head; an interior case with sliding black metal lid located at top left corner contains a small silver metal jar of yellow grease, an oval-shaped catheter clip, a silver-coloured metal connecting nipple, four black rubber nipples and four ochre-coloured rubber nipples (two sizes).
Number Of Parts
20
Part Names
a - walnut case - Size: Length 36.9 cm. x Width 18.0 cm. x Depth 6.5 cm.
b - sliding metal lid for inside case - Size: Length 20.7 cm. x Width 2.9 cm. x Depth 1.0 mm.
c - examining telescope - Size: Length 25.9 cm. x Width 3.4 cm. x Depth 5.0 mm.
d - convex sheath - Size: Length 25.0 cm. x Width 5.0 cm. x Depth 6.0 mm.
e - obdurator - Size: Length 25.7 cm. x Width 1.7 cm. x Depth 3.0 mm.
f - double catheterizing telescope - Size: Length 28.7 cm. x Width 4.2 cm. x Depth 6.0 mm.
g - concave sheath - Size: Length 25.0 cm. x Width 5.7 cm. x Depth 7.0 mm.
h - cleaning hook - Size: Length 26.3 cm. x Width 1.8 cm. x Depth 3.0 mm.
i - catheter clip - Size: Length 6.8 cm. x Width 2.0 cm. x Depth 6.0 mm.
j - connector nipple - Size: Length 2.3 cm. x Width 1.0 mm.
k - grease jar - Size: x Width 1.9 cm. x Diameter8.0 cm.
l - grease jar lid - Size: x Width 6.0 mm. x Diameter8.0 cm.
m-n - rubber nipple - black (x2) - Size: Length 1.7 cm. x Width 9.0 mm.
o-p - rubber nipple - ochre (x2) - Size: Length 1.7 cm. x Width 9.0 mm.
q-r - rubber nipple - small black (x2) - Size: Length 1.3 cm. x Width 8.0 mm.
s-t - rubber nipple, ochre (small) (x2) - Size: Length 1.3 cm. x Width 8.0 mm.
Provenance
Used by Dr. J. A. Low at the Bladder Function Clinic, Kingston General Hospital, from 1965 to 1970.
(a) sticker on interior of case reads, "INGRAM & BELL // LIMITED // TORONTO // MONTREAL - WINNIPEG CALGARY VANCOUVER"; nameplate reads, "BROWN-BUERGER // CYSTOSCOPE // OCCASIONALLY GREASE CONE OF TELESCOPE TO PREVENT LEAKAGE // AND ASSURE SMOOTH ACTION OF LOCK. TO RENEW LAMP, UNSCREW // LAMP CHAMBER CAP USING RUBBER TIP AS ILLUSTRATED. // THE CORRECT LAMP FOR // THIS INSTRUMENT IS: // A.C.M.I. NO 51 // CYSTOSCOPE // RUBBER TIP // GREASE THREADS BEFORE REPLACING TO EFFECTIVELY SEAL LAMP // CHAMBER AGAINST ADMISSION OF MOISTURE. TO AVOID DAMAGE AND EXPENSIVE REPAIRS, USE GENUINE LAMPS WHICH ARE STAMPED "A . C . M . I" // FOR YOUR PROTECTION. // AMERICAN CYSTOSCOPE MAKERS, INC // DESIGNERS AND SOLE PRODUCES OF WAPPLER AND ACMI INSTRUMENTS SINCE 1900 // NEW YORK, U.S.A."; (lock): "PRESTO LOCK // CO"; (b) "AMERICAN CYSTOSCOPE MAKERS, INC. // NEW YORK, N.Y. // WAPPLER A . C . M . I . TRADE MARK DESIGNERS AND SOLE PRODUCERS OF WAPPLER AND A.C.M.I. INSTRUMENTS SINCE 1900"; (f) "21F" "AMERICAN CYSTOSCOPE // MAKERS, INC., N.Y. // MADE IN U.S.A. // 177443"; (g) "LAMP NO 51 // 21F // AMERICAN CYSTOSCOPE // MAKERS, INC. N.Y. // MADE IN U.S.A. // .18 " (e) "A.C.M.I. // 18 // 21F"; (c) "AMERICAN CYSTOSCOPE // MAKERS, INC. N.Y. // MADE // IN U.S.A. // 21F" "179652"; (d) "18" "LAMP // NO 51 // 21F // AMERICAN CYSTOSCOPE MAKERS, INC. N.Y. // MADE // IN U.S.A."; (k) "A.C.M.I. // GREASE"; (i) "A.C. M.I."; (j) "B-D"
Permanent Location
Storage Room 0010
0010-E7-9
Condition Remarks
(a) slight/moderate scratching of top surface; deepest scratch is 1 cm located 3 cm from front edge and 14.5 cm from left side; bottom surface veneer is flaking off along front edge; lock has rust spots over 20% of surface; interior: shiny patches on bottom surface -- hardened clear substance (6 spots); (b) one-third of back surface has changed colour to a light grey; (c) green residue on lock pins; (d) lamp padding in beak has reddish discolouration; rust spots on interior surface at mouth of lock lever; green residue on exterior at base of lock lever; (f) green residue on lock pins; corrosion on telescope 8.5 cm from tip; corrosion is 1.6 cm long; (g) green residue at base of lock lever; green residue also evident in interior of lock lever at the mouth; pinkish discolouration of padding around light bulb
Copy Type
Original
Reference Types
Person
Book
Reference Comments
"Urological and Allied Diagnostic Instruments and High Frequency Equipment" by American Cystoscope Makers, Inc., pp. 30-31, 38, 146; Dr. James A. Low
Research Facts
Cystoscopes were developed in Europe in the 1870's; ACMI began the American manufacture of cystoscopes in 1908; please see photocopies of instruments; used for examining bladders, urethra, inserting catheters; 16F (French) size most commonly used (refers to the size of the instruments)
An American Cystoscope Makers sheath with a concave beak; sheath is hollow with openings at both ends; bottom end has small lamp next to a screw-off tip which is used to replace used lamps; mouth has lock lever, two stopcocks and two circular rims called flanges, where a rotating contact is normall…
An American Cystoscope Makers sheath with a concave beak; sheath is hollow with openings at both ends; bottom end has small lamp next to a screw-off tip which is used to replace used lamps; mouth has lock lever, two stopcocks and two circular rims called flanges, where a rotating contact is normally attached; sheath rod is slightly oval.
Number Of Parts
1
Provenance
Used by Dr. J.A. Low at the Bladder Function Clinic, Kingston General Hospital, from 1965 to 1975.
Exact model illustrated in ACMI Catalogue for 1952
Material
metal: silver
rubber: black
glass: clear
Inscriptions
"16F. // LAMP // No ["o" superscripted] 49L // AMERICAN CYSTOCSCOPE // MAKERS, INC. N.Y. // MADE // IN U.S.A."
Permanent Location
Storage Room 0010
0010-E7-10
Dimension Notes
Length 24.4 cm. x Width 5.9 cm. x Depth 6.0 mm.
Condition Remarks
Signs of wear around flange frome contact with rotating contact; green residue in dried patches on lock level (outside) next to lever and at the "L" of "LAMP" between stopcocks
Copy Type
Original
Reference Types
Person
Book
Reference Comments
"Urological and Allied Diagnostic Instruments and High Frequency Equipment", American Cystoscope Makers, Inc., pp. 36 & 37; Dr. James A. Low
Research Facts
Part of a Brown-Bueger cystoscope kit; 16F (French) concave sheaths used in most cystoscopes; used in operations of the bladder (such as destroying tumours)
Cystoscope in case, consisting of (a) a convex sheath that is a hollow, cylindrical tube which can house either the obturator (b) or the double catheterizing telescope (d); the bullet-shaped tip of the sheath, which bends at a 45 deg. angle, features an opening to accomodate the obturator and teles…
Cystoscope in case, consisting of (a) a convex sheath that is a hollow, cylindrical tube which can house either the obturator (b) or the double catheterizing telescope (d); the bullet-shaped tip of the sheath, which bends at a 45 deg. angle, features an opening to accomodate the obturator and telescope tips as well as a light bulb; the opposite end has a cast key-like opening for obturator or telescope as well as two small valves that protrude from the sides; the obturator is a thin, solid cylindrical metal instrument with flared ends; the bullet-shaped tip is cast to fit the sheath opening and has a rather sharp bevelled edge; the opposite end has a solid gripping handle that tapers from a rounded cube to a cylinder; the obturator fits inside the sheath with the tip coming out of the sheath opening and the gripping handle fitting tightly against the open end; the eyepiece (c) fits onto the end of the sheath tube; this lens consists of a very short length of hollow cylindrical metal tubing with a glass cover on one end and a round opening on the other; the end with the glass cover has a larger diameter and grooves on the outside edge; the double catheterizing telescope (d) consists of two parallel hollow tubes that are joined along their entire length; on one end the tubes come to a sharp bevelled point and on the other end the tubes are attached to another lens identical to the eyepiece, that has a red-bordered half-moon shaped glass cover; from this end, two small tubes protrude from the eyepiece and flare at their openings; the brown irrigation tube (e) is a brown rubber cylindrical tube which is open at one end; the opposite end has a small metal tube which tapers down to a very minute opening; this tapered metal tube fits into the rubber tube and is held there with a threaded binding; the typed instructions (f) are typewritten and detail the proper method to clean the cystoscope; all of the pieces fit into a purpose-built case (g), which is made of black cloth-covered wood with a green velvet lining on the inside; the case is rectangular in shape, is hinged at the back, and has a metal clasp at the front; the inside of the case has built-in green velvet dividers which conform to each individual piece; on the inside of the top of the case are two cloth straps which could hold additional components; the top of the box has the maker's name on it
Number Of Parts
7
Part Names
a - convex sheath - Size: Length 22.5 cm x Width 3.8 cm x Depth 3.0 cm
b - obturator - Size: Length 24.5 cm x Width 1.0 cm x Depth 1.0 cm
c - eyepiece - Size: Length 1.5 cm x Diam. 2.0 cm
d - double catheterizing telescope - Size: Length 22.0 cm x Diam. 2.0 cm
e - rubber irrigation tube - Size: Length 12.8 cm x Diam. 1.0 cm
f - typed instructions - Size: Length 12.0 cm x Width 13.6 cm
g - cloth-covered case - Size: Length 28.0 cm x Width 6.3 cm x Depth 4.5 cm
Provenance
Used by either Dr. C. H. Bird or Dr. Godfrey Bird, of Gananoque, Ont.
The convex sheath is stamped "MADE BY BOEHM ROCHESTER," as well as the number "32" near the opening for the obturator at the valve end of the instrument; the obturator is stamped "32" and "NOT CONNECTED WITH THE ELECTRO SURGICAL COMPANY;" the typed instructions are marked, "C. H. BIRD, M.D., C.M. H. G. BIRD, M.B., M.R.C.P. (LONDON) - TELEPHONE 90 'Wigborough' Gananoque, Ont.;" the cloth-covered case is marked "Boehm Surgical Instruments Corp., Rochester, N.Y."
Permanent Location
Storage Room 0010
0010-E7-10
Condition Remarks
Each piece shows only minor signs of wear from routine use; the typed instructions are somewhat faded and brittle; the case has minor bubbling on the bottom; the front clasp is seized up and the case will not lock
Copy Type
Original
Reference Types
Book
Reference Comments
"A Comprehensive Guide to Purchasing," by V. Mueller and Company, Chicago, 1956, p. 397 (similar to items GU5200-5240)