Skip header and navigation

7 records – page 1 of 1.

Brodie's-style male catheter

https://mhc.andornot.com/en/permalink/artifact1512
Dates
1920
1930
circa 1920-1930
Collection
Dr. C. M. Bracken Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
Accession Number
993004120 a-b
Description
Metal #10 male catheter with solid insert ending in flattened wire
  2 images  
Accession Number
993004120 a-b
Collection
Dr. C. M. Bracken Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
MeSH Heading
Urology -- instrumentation
MM= Urinary Catheterization -- male
Description
Metal #10 male catheter with solid insert ending in flattened wire
Number Of Parts
2
Part Names
a - catheter - Size: Length 27.5 cm. x Width 1.8 cm. x Diameter0.4 cm.
b - insert - Size: Length 27.5 cm. x Diameter1.5 cm.
Maker
Jetter & Scheerer Corp.
Site Made (City)
Tuttlingen
Site Made (Country)
Germany
Dates
1920
1930
circa 1920-1930
Date Remarks
American Hospital Supply Catalog order # 40395
Material
metal: silver
Inscriptions
Stamped on shaft: "KNY SCHEERER GERMANY 10"; and the J.F. Hartz Logo
Permanent Location
Storage Room 0010
0010-E8-2
Reference Types
Document
JPG
Reference Comments
"Kny-Scheerer Illustrations of Surgical Instruments," 21st ed., 1915, p. 4057; CD #7
Images
Less detail

Coude olive tip catheter

https://mhc.andornot.com/en/permalink/artifact1516
Dates
1910
1920
circa 1910-1920
Collection
Dr. C. M. Bracken Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
Accession Number
993004124
Description
Rubber tube catheter is permanently coiled as its resting position, but still flexible; tubing angles before terminating in a bulbous tip; oval hole is located on underside of tube, before the angle.
Accession Number
993004124
Collection
Dr. C. M. Bracken Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
MeSH Heading
Urology -- instrumentation
MM= Urinary Catheterization -- male
Description
Rubber tube catheter is permanently coiled as its resting position, but still flexible; tubing
angles before terminating in a bulbous tip; oval hole is located on underside of tube, before the angle.
Number Of Parts
1
Provenance
Belonged to Dr. C.M. Bracken
Dates
1910
1920
circa 1910-1920
Date Remarks
Rubber used for catheter and type of rubber
Material
rubber: rust
Permanent Location
Storage Room 0010
0010-E8-1
Dimension Notes
Length: 43.0 cm. x Diam. : 0.6 cm.
Less detail

Coude olive tip catheter

https://mhc.andornot.com/en/permalink/artifact1517
Dates
1910
1920
circa 1910-1920
Collection
Dr. C. M. Bracken Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
Accession Number
993004125
Description
Rubber tube catheter is permanently coiled as its resting position, but still flexible; tubing angles before terminating in a bulbous tip; oval hole is located on underside of tube, before the angle.
Accession Number
993004125
Collection
Dr. C. M. Bracken Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
MeSH Heading
Urology -- instrumentation
MM= Urinary Catheterization -- male
Description
Rubber tube catheter is permanently coiled as its resting position, but still flexible; tubing
angles before terminating in a bulbous tip; oval hole is located on underside of tube, before the angle.
Number Of Parts
1
Provenance
Belonged to Dr. C.M. Bracken
Maker
The J.F. Hartz Co.
Site Made (Country)
United States of America
Dates
1910
1920
circa 1910-1920
Date Remarks
Type of rubber
Material
rubber: rust
Inscriptions
Hand-stamped in black ink: "J.F. HARTZ CO. / MADE IN U.S.A."
Permanent Location
Storage Room 0010
0010-E8-1
Dimension Notes
Length: 19.0 cm. x Diam. : 0.6 cm.
Less detail

Coxeter prostatic catheter

https://mhc.andornot.com/en/permalink/artifact1513
Dates
1920
1930
circa 1920-1930
Collection
Dr. C. M. Bracken Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
Accession Number
993004121 a-b
Description
Metal #10 male catheter with simple wire insert Note: match for # 993.004.122
  2 images  
Accession Number
993004121 a-b
Collection
Dr. C. M. Bracken Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
MeSH Heading
Urology -- instrumentation
MM= Urinary Catheterization -- male
Description
Metal #10 male catheter with simple wire insert
Note: match for # 993.004.122
Number Of Parts
2
Part Names
a - catheter - Size: Length 26.0 cm. x Width 2.3 cm. x Diam. 0.5 cm.
b - insert - Size: Length 29.1 cm. x Diam. 0.1 cm.
Site Made (Country)
Germany
Dates
1920
1930
circa 1920-1930
Date Remarks
American Hospital Supply Catalog order # 40395
Material
metal: silver
Inscriptions
Stamped on shaft: "GERMANY" "10"
Permanent Location
Storage Room 0010
0010-E8-2
Reference Types
Book
Other
JPG
Reference Comments
"Sklar Products Surgical Instruments Catalog," 17th ed., 1967, p. 298; 993.004.122; CD #3
Images
Less detail

hydrocele trocars

https://mhc.andornot.com/en/permalink/artifact1519
Collection
Dr. C. M. Bracken Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
Accession Number
993004127 a-j
Description
Set of four nested trocars with cannulae which store in hollow of handle; handle is pear-shaped with ridges; neck of handle has internal and external threading; hollow cylinder cover has one closed end, screws onto handle to encase nesting trocars
Accession Number
993004127 a-j
Collection
Dr. C. M. Bracken Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
MeSH Heading
Drainage -- instrumentation
MM= Catheterization -- paracentesis -- trocar
Description
Set of four nested trocars with cannulae which store in hollow of handle; handle is pear-shaped
with ridges; neck of handle has internal and external threading; hollow cylinder cover has one
closed end, screws onto handle to encase nesting trocars
Number Of Parts
10
Part Names
a - handle - Size: Length 9.0 cm. x Width 2.4 cm. x Depth 1.0 cm.
b - outside case - Size: Length 5.5 cm. x Diameter1.0 cm.
c - longest punch - Size: Length 8.5 cm. x Diameter0.5 cm.
d - sheath - Size: Length 6.5 cm. x Diameter5.5 cm.
e - punch - Size: Length 7.5 cm. x Diameter0.4 cm.
f - sheath - Size: Length 5.5 cm. x Diameter0.4 cm.
g - punch - Size: Length 6.0 cm. x Diameter2.5 cm.
h - sheath - Size: Length 5.0 cm. x Diameter0.3 cm.
i - shortest punch - Size: Length 5.5 cm. x Diameter0.1 cm.
j - sheath - Size: Length 4.5 cm. x Diameter1.5 cm.
Maker
A. S. Aloe Co.
Site Made (Country)
Germany
Date Remarks
American Hospital Catalogue order # 40425
Material
metal: silver
Inscriptions
Stamped on (b): "A.S. ALOE CO. // GERMANY"
Permanent Location
Storage Room 0010
0010-E8-3
Condition Remarks
# 1: (a-b): shows wear; (e-h): tip corroded; (i-j): shaft & tip corroded; # 2: no damage; #3: rusty
Reference Types
Book
Reference Comments
"Illustrated Catalog of Standard Surgical Instruments," by Codman and Shurtleff, ca 1920,
p. 111, item 4370
Exhibit History
Hall of Honour - Bracken Exhibit
Less detail
Dates
1920
1930
circa 1920-1930
Collection
Dr. C. M. Bracken Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
Accession Number
993004122 a-b
Description
Metal #10 male catheter with simple wire insert Note: match for # 993.004.121
  2 images  
Accession Number
993004122 a-b
Collection
Dr. C. M. Bracken Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
MeSH Heading
Urology -- instrumentation
MM= Urinary Catheterization -- male
Description
Metal #10 male catheter with simple wire insert
Note: match for # 993.004.121
Number Of Parts
2
Part Names
a - catheter - Size: Length 27.0 cm. x Width 2.4 cm. x Diameter0.7 cm.
b - insert - Size: Length 30.0 cm. x Diameter0.1 cm.
Maker
Jetter & Scheerer
Site Made (City)
Tuttlingen
Site Made (Country)
Germany
Dates
1920
1930
circa 1920-1930
Material
metal: silver
Inscriptions
Stamped with Jetter & Scheerer logo, consisting of a caduceus (i.e., a sceptre with a snake wrapped around it forming an "S") topped by a pointed crown
Permanent Location
Storage Room 0010
0010-E8-2
Reference Types
Book
Other
JPG
Reference Comments
"Sklar Products Surgical Instruments Catalog," 17th ed., 1967, p. 298, item 390-115; 993004121; CD #3
Images
Less detail

urinalysis report

https://mhc.andornot.com/en/permalink/artifact1701
Dates
1937
circa 1937
Collection
Dr. C. M. Bracken Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
Accession Number
993004310
Description
Urinalysis report, which consists of a single sheet of paper with printed and handwritten information regarding a urinalysis done at the Brockville General Hospital
Accession Number
993004310
Collection
Dr. C. M. Bracken Collection
Category
Diagnostic & Treatment Artifacts
Classification
Urology
MeSH Heading
Urinalysis -- statistics and numerical data
Description
Urinalysis report, which consists of a single sheet of paper with printed and handwritten information
regarding a urinalysis done at the Brockville General Hospital
Number Of Parts
1
Provenance
Used by Dr. C.M. Bracken, 1923 Queen's Meds. graduate, who practiced medicine from 1923
to 1963
Dates
1937
circa 1937
Date Remarks
Report dated January 7, 1937
Material
paper: yellow
Inscriptions
Report reads, "Brockville General Hospital // URINALYSIS REPORT // Jan 7 1937 // Name Cavous L //
Address // Room // Ward // Doctor Bracken // Time // Volume // c.c. // Color Watery // Odor //
Appearance Clear // Reaction alk (?) // Specific Gravity 1.012 // Quantity %, or Grams in 24 Hours
// Diacetic Acid // Urea // Acetone // Phosphates // Bile // Urates // Blood (Benzidine Test) //
Fermentation Test (Glucose-Lactose) // Microscopical // Pus per H.P.F. // Blood Cells // Bacteria
// Amorphous Deposit // Epithelium // Casts // Crystals // Miscellaneous: // Examiner ______";
the back has the words, "Epitenon // Tenorrhaply // Epineurium" handwritten in ink
Permanent Location
Storage Room 2005
2005-2-2 Box #7
Dimension Notes
Length: 17.8 cm. x Width: 23.4 cm.
Condition Remarks
The paper has 5 small holes in it and the edges are slightly dog-eared; very small sections are
missing from the top and the lower left corner; the paper has been folded into four and the fold
lines remain; all printing is legible; all writing is visible, but some words are hard to read
Copy Type
Original
Exhibit History
On exhibit in Hall of Honour, KGH, from April 17 1994 to Sept. 27 1997; 5 holes were put into the
paper when it was nailed up for display
Less detail

7 records – page 1 of 1.