Skip header and navigation

Refine By

   MORE

16 records – page 1 of 2.

Legend pacemaker

https://mhc.andornot.com/en/permalink/artifact206
Dates
1980
1990
circa 1980-1990
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007151
Description
Internal pacemaker; oblong shape; stainless steel; translucent plastic attachment to top; with insert for wire to one end of attachment; maker name and model info engraved to front surface.
  1 image  
Accession Number
994007151
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; oblong shape; stainless steel; translucent plastic attachment to top; with insert for wire to one end of attachment; maker name and model info engraved to front surface.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Medtronic
Site Made (Country)
Canada
Dates
1980
1990
circa 1980-1990
Date Remarks
estimate
Material
metal: silver
plastic: clear
Inscriptions
Engraved to front: "Legend™ // SS1R MODEL 8419 // 2T4100189M // MEDTRONIC // CANADA"
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 5.5 cm. x Width: 4.2 cm. x Depth: 0.8 cm.
Copy Type
Original
Images
Less detail

Activitrax 8400 pulse generator

https://mhc.andornot.com/en/permalink/artifact207
Dates
1980
1999
circa 1980-1999
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007152
Description
Internal pacemaker; oblong shape; stainless steel; clear plastic attachment to top; with insert for wire; maker name and model information engraved to front surface.
  1 image  
Accession Number
994007152
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; oblong shape; stainless steel; clear plastic attachment to top; with insert for wire; maker name and model information engraved to front surface.
Number Of Parts
1
Maker
Medtronic
Site Made (City)
Minneapolis
Site Made (State)
Mn.
Site Made (Country)
United States of America
Dates
1980
1999
circa 1980-1999
Date Remarks
estimate
Material
metal: silver
plastic: clear
Inscriptions
Engraved to front: ACTIVITRAX 8400 // VVIC + ACTIVITY // PULSE GENERATOR // IJ2301 337H // MEDTRONIC INC. // MINNEAPOLIS, MN USA
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 6.0 cm. x Width: 4.3 cm. x Depth: 1.0 cm.
Copy Type
Original
Images
Less detail

Nova II pacemaker demo model

https://mhc.andornot.com/en/permalink/artifact270
Dates
1980
1990
circa 1980-1990
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007215
Description
Demonstration model; internal pacemaker; oblong shape; silver plastic unit; clear plastic attachment to top; with insert for wire to attachment; maker name and model information imprinted to front and back.
  2 images  
Accession Number
994007215
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial -- models
Description
Demonstration model; internal pacemaker; oblong shape; silver plastic unit; clear plastic attachment to top; with insert for wire to attachment; maker name and model information imprinted to front and back.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Intermedics Inc.
Site Made (City)
Freeport
Site Made (State)
Texas
Site Made (Country)
United States of America
Dates
1980
1990
circa 1980-1990
Material
plastic: silver; clear
Inscriptions
Imprinted to front: Intermedics Inc. // FREEPORT TEXAS // NOVA II // Model 282-04 // SSI SST SOO; imprinted to back: Not for Human Implant
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 5.0 cm. x Width: 3.7 cm. x Depth: 0.6 cm.
Copy Type
Other
Exhibit History
May 24 - Sept. 13, 2001: Agnes Etherington Art Centre Museopathy exhibit
Images
Less detail

Mirel pulse generator demo model

https://mhc.andornot.com/en/permalink/artifact275
Dates
1980
1990
circa 1980-1990
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007220
Description
Demonstration model; internal pacemaker; circular shape; stainless steel; with plastic attachment to top; insert for wire to attachment; maker and model information imprinted to front and back.
  1 image  
Accession Number
994007220
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial -- models
Description
Demonstration model; internal pacemaker; circular shape; stainless steel; with plastic attachment to top; insert for wire to attachment; maker and model information imprinted to front and back.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Medtronic
Dates
1980
1990
circa 1980-1990
Material
metal: silver
plastic: clear
Inscriptions
To front: MIREL // LITHIUM POWERED // PULSE GENERATORS // BY // MEDTRONIC
Permanent Location
Storage Room 0010
0010-E6-1
Dimension Notes
Length: 5.0 cm. x Width: 5.5 cm. x Depth: 1.0 cm.
Copy Type
Other
Exhibit History
May 24 - Sept. 13, 2001: Agnes Etherington Art Centre Museopathy exhibit
Images
Less detail

pacemaker sensor

https://mhc.andornot.com/en/permalink/artifact56
Dates
1970
1990
circa 1970-1990
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007001
Description
Cream plastic rectangular-shaped battery-operated pacemaker sensor for standby use only, made by General Electric; has removable back by single screw; battery removed Feb 8/94; clear plastic diagram attached to back lid.
  2 images  
Accession Number
994007001
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Cream plastic rectangular-shaped battery-operated pacemaker sensor for standby use only, made by General Electric; has removable back by single screw; battery removed Feb 8/94; clear plastic diagram attached to back lid.
Number Of Parts
1
Part Names
a - back lid - Size:
b - sensor - Size:
Provenance
Used at Kingston General Hospital.
Maker
General Electric
Site Made (Country)
United States of America
Dates
1970
1990
circa 1970-1990
Material
plastic: cream
metal: silver; black
Inscriptions
"GENERAL ELECTRIC" "PACEMAKER SENSOR // MADE IN U.S.A." "FOR STANDBY ONLY // CAT. A2074AC SER. 966171"
Permanent Location
Storage Room 0007
0007-J2-5
Dimension Notes
Length: 15.5 cm. x Width: 7.7 cm. x Depth: 5.7 cm.
Condition Remarks
slight stain by screw
Images
Less detail

pacemaker sensor

https://mhc.andornot.com/en/permalink/artifact57
Dates
1980
1990
circa 1980-1990
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007002
Description
Cream plastic rectangular-shaped battery-operated pacemaker sensor for standby use only, made by General Electric; has removable back by single screw; battery removed Feb 8/94; interior circuit board is covered by cover & magnetic sensor is covered by cream plastic cap.
  2 images  
Accession Number
994007002
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Cream plastic rectangular-shaped battery-operated pacemaker sensor for standby use only, made by General Electric; has removable back by single screw; battery removed Feb 8/94; interior circuit board is covered by cover & magnetic sensor is covered by cream plastic cap.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
General Electric
Site Made (Country)
United States of America
Dates
1980
1990
circa 1980-1990
Material
plastic: cream
metal
Inscriptions
GENERAL ELECTRIC // PACEMAKER SENSOR // MADE IN U.S.A. // FOR STANDBY ONLY // CAT. A2074AB SER. 912674
Permanent Location
Storage Room 0007
0007-J2-5
Dimension Notes
Length 15.5 cm. x Width 7.7 cm. x Depth 5.7 cm.
Condition Remarks
slight stain on back
Images
Less detail

pacing system analyzer

https://mhc.andornot.com/en/permalink/artifact59
Dates
1970
1993
circa 1970-1993
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007004
Description
Bright blue plastic battery-operated pacing system analyser for pacemakers; has a removable metal plate and battery holder; batteries removed Feb 8/94; back of machine has applied sticker showing operating functions.
  2 images  
Accession Number
994007004
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Cardiac Pacing, Artificial -- instrumentation
Cardiology -- instrumentation
Description
Bright blue plastic battery-operated pacing system analyser for pacemakers; has a removable metal plate and battery holder; batteries removed Feb 8/94; back of machine has applied sticker showing operating functions.
Number Of Parts
1
Part Names
a - plate - Size: Length 14.3 cm. x Width 8.5 cm. x Depth 0.1 cm.
b - battery holder - Size: Length 6.0 cm. x Width 3.0 cm. x Depth 3.2 cm.
Provenance
Used at Kingston General Hospital.
Maker
Medtronics
Dates
1970
1993
circa 1970-1993
Material
plastic: light blue; white; black
metal: silver; white; blue
Inscriptions
"MEDTRONICS™ 5300 // PACING SYSTEM ANALYZER // 4BY0507"
Permanent Location
Storage Room 0007
0007-J2-5
Dimension Notes
Length 21.7 cm. x Width 8.8 cm. x Depth 7.1 cm.
Condition Remarks
shows wear
Reference Comments
Images lost
Images
Less detail

pacemaker rate controller

https://mhc.andornot.com/en/permalink/artifact60
Dates
1970
1993
circa 1970-1993
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007005
Description
Hand-held bright blue plastic Medtronics 9600 rate controller for pacemakers; lift of paper face plate has different readings than original.
  2 images  
Accession Number
994007005
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Cardiac Pacing, Artificial -- instrumentation
Cardiology -- instrumentation
Description
Hand-held bright blue plastic Medtronics 9600 rate controller for pacemakers; lift of paper face plate has different readings than original.
Number Of Parts
1
Part Names
a - paper faceplate - Size: Length 8.0 cm. x Width 8.0 cm.
Provenance
Used at Kingston General Hospital.
Maker
Medtronics
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1970
1993
circa 1970-1993
Material
plastic: bright blue; white; black
metal: silver; black
paper: black; white
Inscriptions
MEDTRONIC (R) 9600 // RATE CONTROLLER // MINNEAPOLIS, MINNESOTA USA // 142471-001
Permanent Location
Storage Room 0007
0007-J2-4
Dimension Notes
Length 21.5 cm. x Width 9.8 cm. x Depth 8.0 cm.
Condition Remarks
shows wear
Images
Less detail

Pacer-Tracer telephone transmitter

https://mhc.andornot.com/en/permalink/artifact61
Dates
1980
1993
circa 1980-1993
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007006
Description
Small black plastic battery-operated Pacer-Tracer transmitter by Instromedix; fits into hand; unable to open battery area to remove battery Feb 8/94.
  3 images  
Accession Number
994007006
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Cardiac Pacing, Artificial -- instrumentation
Cardiology -- instrumentation
Description
Small black plastic battery-operated Pacer-Tracer transmitter by Instromedix; fits into hand; unable to open battery area to remove battery Feb 8/94.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Instromedix Inc.
Site Made (City)
Beaverton
Site Made (State)
Oregon
Site Made (Country)
United States of America
Dates
1980
1993
circa 1980-1993
Material
plastic: black
metal: silver; black
Inscriptions
PACER-TRACER // Instromedix, Inc. // Beaverton, Ore. 97005 // USA U.S. and Foreign // Patents pending // SERIAL NO. // M-1146 // Mfg. by // INSTROMEDIX, INC. // Beaverton, OR, USA // This transmitter generates a Pacemaker // artifact similar to the Medtronic // Teletrace System
Permanent Location
Storage Room 0010
0010-E6-7
Dimension Notes
Length 11.6 cm. x Width 6.4 cm. x Depth 2.8 cm.
Reference Types
Document
Reference Comments
Instructions on the artifact
Research Facts
Instrument for transmitting pacemaker function data via telephone (known as transtelephonic monitoring)
Images
Less detail

research orthorhythmic pacemaker

https://mhc.andornot.com/en/permalink/artifact63
Dates
1980
1993
circa 1980-1993
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007008 a-c
Description
Tabletop metal research orthorhythmic pacemaker by G.E.; has auxiliary grey cord with copies of manual (written in French) and evaluation reports put into orange General Electric binder.
  5 images  
Accession Number
994007008 a-c
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Tabletop metal research orthorhythmic pacemaker by G.E.; has auxiliary grey cord with copies of manual (written in French) and evaluation reports put into orange General Electric binder.
Number Of Parts
3
Part Names
a - pacemaker - Size: Length 44.0 cm. x Width 40.0 cm. x Depth 23.5 cm.
b - grey cord - Size: Length 368.0 cm. x Width 1.2 cm. x Diameter0.7 cm.
c - manual - Size: Length 22.3 cm. x Width 24.7 cm. x Depth 2.2 cm.
Provenance
Used at Kingston General Hospital.
Maker
General Electric
Site Made (City)
Milwaukee
Site Made (State)
Wisconsin
Site Made (Country)
United States of America
Dates
1980
1993
circa 1980-1993
Material
plastic: blue; red; yellow; green; grey
metal: silver; blue; grey
paper: orange
Inscriptions
RESEARCH ORTHORHYTHMIC PACEMAKER / PROPERTY OF GENERAL ELECTRIC CO // 315 W EDGERTON AVE. // MILWAUKEE, WISC. 53200 // TO SERVICE THIS MACHINE CALL: (414)383-3211 EXT. 7407
Permanent Location
Storage Room 0007
0007-J2-4
Images
Less detail