Skip header and navigation

Refine By

13 records – page 1 of 2.

Dates
1910
circa 1910
Collection
Dr. Michael A. Chiong Patent Medicine Collection
Category
Ephemera
Classification
Ephemera
Accession Number
996001803
Description
Paper envelope from Blacking & Mercantile Co., Ltd. to Messrs. J. & W. Jean; front: handwritten address; facsimile on the left of Mathieu's Syrup of Tar; red 2c Canadian stamp; back: red lithograph of their building; opened at top
  2 images  
Accession Number
996001803
Collection
Dr. Michael A. Chiong Patent Medicine Collection
Category
Ephemera
Classification
Ephemera
MeSH Heading
Drugs, Non-Prescription, advertisements
Correspondence, ephemera
Cod Liver Oil -- advertisements
MM= Drugs -- patent, proprietary, over-the-counter -- advertisements
Description
Paper envelope from Blacking & Mercantile Co., Ltd. to Messrs. J. & W. Jean; front: handwritten
address; facsimile on the left of Mathieu's Syrup of Tar; red 2c Canadian stamp; back: red lithograph
of their building; opened at top
Number Of Parts
1
Provenance
Purchased by Dr. Chiong for his patent medicine collection, before July 15, 1995
Maker
Blacking & Mercantile Co., Ltd.
Site Made (City)
Amherst
Site Made (State)
Nova Scotia
Site Made (Country)
Canada
Dates
1910
circa 1910
Date Remarks
Postmarked Nov. 2, 1910
Material
paper: black; red; blue
Inscriptions
"Messrs. J. & W. Jean, // Arichat, // C.B. [ie, Cape Breton] // BLACKING & MERCANTILE CO., Ltd.
// Canadian Proprietors: U.N.O Blacking and E. & B. Non-Corrosive Inks // Maritime Agents: MATHIEU'S
SYRUP OF TAR and COD LIVER [OIL] // Selling Agents: Maritime Handling Co. // SUCCESSORS TO
// FILLMORE ..."; etc.
Permanent Location
Storage Room 2005
2005-5-6
Binder E
Dimension Notes
Length: 16.5 cm. x Width: 9.3 cm.
Condition Remarks
Some age/sun discolouration; a lot of mathematical doodling, especially on the back
Copy Type
Original
Reference Types
Other
JPG
Reference Comments
See 996.001.796; CD #8
Research Facts
See 996.001.796
Images
Less detail

commemorative stamp

https://mhc.andornot.com/en/permalink/artifact2876
Dates
6-May-81
circa 6 May 1981
Collection
Dr. Michael A. Chiong Patent Medicine Collection
Category
Archival Items
Classification
Archival, Publications
Accession Number
996001839
Description
First day cover commemorating centenary of pharmaceutical education in Australia, with stamp, postmark, and illustration of a chemist's shop with leaves, etc., on envelope.
  2 images  
Accession Number
996001839
Collection
Dr. Michael A. Chiong Patent Medicine Collection
Category
Archival Items
Classification
Archival, Publications
MeSH Heading
Philately -- ephemera
Education, Pharmacy -- ephemera
Description
First day cover commemorating centenary of pharmaceutical education in Australia, with stamp, postmark, and illustration of a chemist's shop with leaves, etc., on envelope.
Number Of Parts
1
Provenance
Purchased by Dr. Chiong for his patent medicine collection, before July 15, 1995.
Maker
Australia Post
Site Made (City)
Melbourne
Site Made (Country)
Australia
Dates
6-May-81
circa 6 May 1981
Date Remarks
Postmark
Material
paper: brown; blue; red; white; black; yellow; green; pink
Inscriptions
"Centenary of Pharmaceutical Education in Australia // PHILATELIC BUREAU MELBOURNE AUSTRALIA 3000
// FIRST DAY OF ISSUE // 6 MAY 1981 // Australia 22c"
Permanent Location
Storage Room 2005
2005-2-2 Box #6
Dimension Notes
Length: 10.1 cm. x Width: 19.0 cm.
Condition Remarks
No marks or tears
Copy Type
Original
Research Facts
See back of envelope
Images
Less detail

mounted ivory tusk

https://mhc.andornot.com/en/permalink/artifact13684
Dates
1-May-75
circa May 1, 1975
Collection
Dr. Ralph and Mrs. Olga Crawford Canadian Dental Collection
Category
Diagnostic & Treatment Artifacts
Classification
Dental
Accession Number
010020516
Description
Small ivory tusk mounted on a dark brown wood base with a green felt bottom; tusk is ivory in colour and tapers towards the end to form a dull point; the base of the tusk has small grooves in it which are beige in colour which gradually disappear towards the tip; there is a sticker on the felt with…
  3 images  
Accession Number
010020516
Collection
Dr. Ralph and Mrs. Olga Crawford Canadian Dental Collection
Category
Diagnostic & Treatment Artifacts
Classification
Dental
MeSH Heading
Tooth
Dentistry -- veterinary
Description
Small ivory tusk mounted on a dark brown wood base with a green felt bottom; tusk is ivory in colour and tapers towards the end to form a dull point; the base of the tusk has small grooves in it which are beige in colour which gradually disappear towards the tip; there is a sticker on the felt with the maker's information printed in black ink and a date handwritten in black ink.
Number Of Parts
1
Provenance
Transfer from the Dental Canada Fund; previously housed in the Dentistry Canada Museum (Ottawa)
Maker
C.J. & F.L. Cooper
Site Made (City)
Frenchman Bay
Site Made (State)
Western Australia
Site Made (Country)
Australia
Dates
1-May-75
circa May 1, 1975
Date Remarks
Date is handwritten on bottom of base
Material
ivory: ivory, beige
wood: brown
ink: black
Inscriptions
Printed in ink on sticker on the bottom of base: "Hand made by // C.J. & F.L. // COOPER // Frenchman Bay // W.A. 6330"; handwritten in ink on sticker: "MAY 1/75"
Permanent Location
Storage Room 0010
0010-B
Dimension Notes
Length 11.2 cm x Width 6.3 cm x Depth 10.7 cm
Condition Remarks
There are two small cracks in the ivory at the tip
Copy Type
Original
Reference Types
JPG
Reference Comments
CD #4
Research Facts
Dr Ralph and Mrs Olga Crawford donated their extensive Canadian dental collection to the DCF to create the museum in 1997; further donations were received while Dr Crawford was Curator Emeritus at the Dental Canada Museum until its closure in 2008
Images
Less detail
Dates
1984
circa 1984
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007044
Description
Internal pacemaker; rectangular form; stainless steel; with transparent rubber coating; transparent rubber attachment to top; input socket for wires; maker and unit information etched into front surface. Weight: 63.0 g.
  2 images  
Accession Number
994007044
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rectangular form; stainless steel; with transparent rubber coating; transparent rubber attachment to top; input socket for wires; maker and unit information etched into front surface. Weight: 63.0 g.
Number Of Parts
1
Maker
Telectronics
Site Made (City)
Sydney
Site Made (Country)
Australia
Dates
1984
circa 1984
Date Remarks
Dr. Chiong's estimate
Material
rubber: clear
metal: silver
Inscriptions
etched to front surface: TELECTRONICS // SYDNEY AUSTRALIA // 174 / 50
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length 6.4 cm. x Depth 5.0 cm. x Diam. 0.7 cm.
Condition Remarks
Overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #3; CD #1
Exhibit History
Pacemaker Exhibit - KGH Cardiology Unit Dec. 1994
Images
Less detail
Dates
1984
circa 1984
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007060
Description
Internal pacemaker; rectangular shape; stainless steel; with rubber epoxy casing; rubber attachment to top, with split wire inserted to one side; wire encased in epoxy rubber; maker mark, name and info engraved to front surface Note: in wire: length 13.0 width 7.0
  1 image  
Accession Number
994007060
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rectangular shape; stainless steel; with rubber epoxy
casing; rubber attachment to top, with split wire inserted to one side; wire
encased in epoxy rubber; maker mark, name and info engraved to front surface
Note: in wire: length 13.0 width 7.0
Number Of Parts
1
Maker
Telectronics
Site Made (City)
Sydney
Site Made (Country)
Australia
Dates
1984
circa 1984
Date Remarks
Dr. Chiong's notes
Material
metal: silver
rubber: clear
Inscriptions
Engraved to front: TELECTRONICS // SYDNEY AUSTRALIA // 174 50
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 6.5 cm. x Width: 5.0 cm. x Depth: 1.2 cm.
Condition Remarks
overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #4
Exhibit History
"Pacemakers: Technology Development," HDH, 14 Feb. 2007
Images
Less detail
Dates
1984
circa 1984
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007061
Description
Internal pacemaker; rectangular shape; stainless steel; with rubber epoxy casing; rubber attachment to top, with split wire inserted to one side; maker mark, name and info engraved to front surface Note: in wire: length 13.0 width 7.0
  2 images  
Accession Number
994007061
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rectangular shape; stainless steel; with rubber epoxy
casing; rubber attachment to top, with split wire inserted to one side;
maker mark, name and info engraved to front surface
Note: in wire: length 13.0 width 7.0
Number Of Parts
1
Maker
Telectronics
Site Made (City)
Sydney
Site Made (Country)
Australia
Dates
1984
circa 1984
Date Remarks
Dr. Chiong's notes
Material
metal: silver
rubber: clear
Inscriptions
Engraved to front: TELECTRONICS // SYDNEY AUSTRALIA // 174 50
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 6.5 cm. x Width: 5.0 cm. x Depth: 1.2 cm.
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #4
Images
Less detail

Soluvac intravenous outfit

https://mhc.andornot.com/en/permalink/artifact8316
Dates
1950
circa 1950
Collection
University Health Network - Academy of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Treatment, General
Accession Number
1984.10.1
Description
A cardboard box containing the following parts in sealed paper envelopes: intravenous tubing five feet long, drip control tube-glass, connecting tube-glass, needle in glass holder, metal clamp; two instructions sheets are included.
  1 image  
Accession Number
1984.10.1
Collection
University Health Network - Academy of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Treatment, General
MeSH Heading
Infusions, Intravenous
Description
A cardboard box containing the following parts in sealed paper envelopes: intravenous tubing five feet long, drip control tube-glass, connecting tube-glass, needle in glass holder, metal clamp; two instructions sheets are included.
Part Names
box - Size: Length 18.1 cm x Width 14.6 cm x Depth 2.5 cm
Provenance
Acquired from the Academy of Medicine; source: Mrs. C.A. McRae; used by Dr. C.A. McRae, G.P. in Thornhill, Ont. 1930s-1983.
Maker
Elliotts & Australian Drug Pty. Ltd.
Site Made (City)
Sydney
Site Made (Country)
Australia
Dates
1950
circa 1950
Material
paper: yellowish-brown; white
ink: black
rubber
glass
metal
Permanent Location
Storage Room 0010
0010-D5-9
Condition Remarks
Unused; paper is fragile.
Copy Type
Original
Reference Types
JPG
Reference Comments
CD #UHN
Images
Less detail

pulse generator

https://mhc.andornot.com/en/permalink/artifact146
Dates
1979
circa 1979
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007091
Description
Internal pacemaker; rectangular shape; stainless steel; cloudy white rubber attachment to top; with a rubber-coated wire inserted to one end of attachment; stainless steel unit encased in epoxy; maker mark, name and information engraved to front and back surfaces
  1 image  
Accession Number
994007091
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rectangular shape; stainless steel; cloudy white rubber
attachment to top; with a rubber-coated wire inserted to one end of attachment;
stainless steel unit encased in epoxy; maker mark, name and information
engraved to front and back surfaces
Number Of Parts
1
Maker
Telectronics
Site Made (City)
Sydney
Site Made (Country)
Australia
Dates
1979
circa 1979
Date Remarks
Dr. Chiong's notes
Material
metal: silver
rubber: white
epoxy: clear
Inscriptions
Engraved to front: TELECTRONICS // SYDNEY AUSTRALIA // S A414482099;
Engraved to back: MODEL 171 // VVI // PROGRAMMABLE // PULSE GENERATOR //
THIS SIDE AWAY // FROM MUSCLE
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 6.4 cm. x Width: 6.0 cm. x Depth: 1.2 cm.
Condition Remarks
overall condition good; #3: rubber requires special treatment
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #3
Images
Less detail

pulse generator

https://mhc.andornot.com/en/permalink/artifact147
Dates
1979
circa 1979
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007092
Description
Internal pacemaker; rectangular shape; stainless steel; with clear epoxy encasing; rubber attachment to top; with a rubber-coated wire inserted to to one end of attachment; maker mark, name and information engraved to front and back surfaces
  1 image  
Accession Number
994007092
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rectangular shape; stainless steel; with clear epoxy
encasing; rubber attachment to top; with a rubber-coated wire inserted to
to one end of attachment; maker mark, name and information engraved to
front and back surfaces
Number Of Parts
1
Maker
Telectronics
Site Made (City)
Sydney
Site Made (Country)
Australia
Dates
1979
circa 1979
Date Remarks
Dr. Chiong's notes
Material
metal: silver
rubber: white
epoxy: clear
Inscriptions
Engraved to front: TELECTRONICS // SYDNEY AUSTRALIA // S A403899109;
Engraved to back: MODEL 171 // VVI // PROGRAMMABLE // PULSE GENERATOR //
THIS SIDE AWAY // FROM MUSCLE
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 6.4 cm. x Width: 6.0 cm. x Depth: 1.2 cm.
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #3
Images
Less detail

pulse generator

https://mhc.andornot.com/en/permalink/artifact148
Dates
1979
circa 1979
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007093
Description
Internal pacemaker; rectangular shape; stainless steel; with clear epoxy encasing; rubber attachment to top; with insert for wire to one side; maker mark, name and information engraved to front and back
Accession Number
994007093
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rectangular shape; stainless steel; with clear epoxy
encasing; rubber attachment to top; with insert for wire to one side;
maker mark, name and information engraved to front and back
Number Of Parts
1
Maker
Telectronics
Site Made (City)
Sydney
Site Made (Country)
Australia
Dates
1979
circa 1979
Date Remarks
Dr. Chiong's notes
Material
metal: silver
rubber: white
epoxy: clear
Inscriptions
Engraved to front: TELECTRONICS // SYDNEY AUSTRALIA // S A403345109;
Engraved to back: MODEL 171 // VVI // PROGRAMMABLE // PULSE GENERATOR //
THIS SIDE AWAY // FROM MUSCLE
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 6.4 cm. x Width: 6.0 cm. x Depth: 1.2 cm.
Condition Remarks
overall condition good
Copy Type
Original
Reference Types
Person
Reference Comments
Dr. Chiong
Less detail