Skip header and navigation

Refine By

174 records – page 1 of 18.

ear, eye, nose and throat diagnostic kit

https://mhc.andornot.com/en/permalink/artifact9566
Dates
1900
1930
circa 1900-1930
Collection
Dr. Burns Collection
Category
Diagnostic & Treatment Artifacts
Physical Examination
Surgery
Surgery, Instrumentation
Vision
Classification
Otolaryngology
Ophthalmology
Diagnosis, Eyes
Surgery
Surgery, instrumentation
Vision
Physical Examination
Accession Number
995005029 a-n
Description
Diagnostic kit, consisting of (a) a leather-covered, rectangular wooden case; the top is hinged at the back with two metal hinges; front has a simple latch with a circular button on the outside as part of the locking mechanism; inside top is satin and bottom is blue velvet over wood cut into holder…
  5 images  
Accession Number
995005029 a-n
Collection
Dr. Burns Collection
Category
Diagnostic & Treatment Artifacts
Physical Examination
Surgery
Surgery, Instrumentation
Vision
Classification
Otolaryngology
Ophthalmology
Diagnosis, Eyes
Surgery
Surgery, instrumentation
Vision
Physical Examination
MeSH Heading
Physical Examination
MM= Exploring Instruments -- probe -- lacrimal
Ophthalmology
Vision
Vision Tests -- instrumentation
Diagnosis, Eyes
Drainage -- instrumentation
MM= Catheterization -- accessories
MM= Exploring Instruments -- probe
Description
Diagnostic kit, consisting of (a) a leather-covered, rectangular wooden case; the top is hinged at the back with two metal hinges; front has a simple latch with a circular button on the outside as part of the locking mechanism; inside top is satin and bottom is blue velvet over wood cut into holders for tools; (b) adjustable metal speculum; top is open; speculum is hollow; two blades, hinged and conical in shape, are adjusted by a metal screw mechanism that attaches to the top above the blade hinges by way of a metal collar; (c-e) conical, hollow, metal speculum, with a short neck extended past flare of collar; bottom tip is open, allowing sight down inside length of speculum; (f,g) circular metal mirror, attached to a thin, cylindrical metal arm and hollow cylindrical collar; (h) cylindrical light; top has glass and is convex; bottom is metal threaded with copper connector; (i) otoscope assembly: main body is a metal cylinder; one side has a lens with a concave, terraced eyepiece; minor cylinder projects from eyepiece; small glass ring projects down from cylinder in a flexible mounting; longer cylinder projects down from main piece; two engraved rings, two smaller cylinders; cylinder back is open with a light similar to (h); (j) ophthalmoscope port: rectangular, made of metal, with a cylinder mounted on top and folded over the bottom; bent metal creates a slot; (k) solid, metal depressor, consisting of a hollow cylinder attached along the bottom to a longer V-shaped piece of flat metal, the top 0.8 cm and curving down, with a blunt convex tip; (l) ophthalmoscope head: the body is composed of a rotating disc of metal, with small, circular glass lenses embedded in the disc, sandwiched between two thin discs of metal, pierced with a circular hole to allow sight through the object; the front plate has both sides cut back to allow easier turning of the embedded disc; the rear plate has an extra semicircle of metal attached to the top; a small strip of metal is attached to the back of the back plate with two screws; it runs in parallel with a metal cylinder, the bottom having a neck, then terracing twice into a single prong--to anchor to the rest of the ophthalmoscope--while the top is cut diagonally at a 60° angle and filled with a glass lens; (m) illuminator, which is a long, curved cylinder of metal with a light at one end and a single prong connection at the other; (n) battery handle, which is a hollow cylinder of leather-covered metal; threading at bottom, closing mechanism missing; top has intact metal assembly with a clip extending down one side of cylinder; above the clip, the metal cylinder is cross-hatched for grip; top of cylinder has semicircular slot and a plastic tab extending from it; centre of top has smaller, cylindrical female single-prong plug with screw for securing connection.
Number Of Parts
14
Part Names
a - case - Size: Length 18.8 cm x Width 18.4 cm x Depth 5.1 cm
b - variable speculum - Size: Length 7.0 cm x Width 4.1 cm x Depth 2.4 cm
c - otoscope speculum (small tip) - Size: Length 4.5 cm x Diam. 2.9 cm
d - otoscope speculum (medium tip) - Size: Length 4.8 cm x Diam. 2.8 cm
e - otoscope speculum (large tip) - Size: Length 4.6 cm x Diam. 2.8 cm
f - laryngoscope mirror (small) - Size: Length 6.0 cm x Width 1.6 cm x Depth 1.6 cm
g - laryngoscope mirror (large) - Size: Length 6.1 cm x Width 2.2 cm x Depth 2.2 cm
h - lamp tip - Size: Length 2.7 cm x Diam. 0.5 cm
i - otoscope assembly - Size: Length 5.2 cm x Width 3.6 cm x Depth 2.1 cm
j - ophthalmoscope part - Size: Length 2.5 cm x Width 2.2 cm x Depth 1.1 cm
k - depressor - Size: Length 7.5 cm x Width 2.2 cm x Depth 1.8 cm
l - ophthalmoscope head - Size: Length 9.4 cm x Width 4.3 cm x Depth 1.6 cm
m - illuminator - Size: Length 13.3 cm x Diam. 0.7 cm
n - battery handle - Size: Length 15.7 cm x Width 4.8 cm x Depth 3.8 cm
Provenance
Owned and used by Dr. Burns of Napanee, Ont., graduate of the Queen's University Faculty of Medicine Clas of 1947; some items belonged to Dr. Stratton, who held the Napanee practice prior to Dr. Burns.
Maker
J. S & S; Klinostik
Site Made (Country)
Britain
Dates
1900
1930
circa 1900-1930
Material
plastic: ivory
metal: silver; yellow; black
leather: black
fabric: blue
Inscriptions
(a) Embroidered letters, inside lid: "KLINOSTIK [a bar over the "O"] REGD. // SUPER DIAGNOSTIC // BRITISH MADE"; (b) engraved on side: "KLINOSTIK // BRITISH MADE"; (i) engraved on side: "KLINOSTIK // BRITISH MADE"; (j) engraved on bottom: "KLINOSTIK // BRITISH MADE"; (l) engraved on front: MAY // OPHTHALMOSCOPE // Improved // J. S&S. // + [rotary dial from 20 through 0 to 20] – // WHITE X-RAY // TORONTO // MADE IN GREAT BRITAIN"; engraved on back: "PAT 808 - 7 [illeg.]"; (n) engraved on top: "OFF"; engraved on the side: "KLINOSTIK [a bar over the "O"] // REGD [the "D" superscr. and underlined]"
Permanent Location
Storage Room 0010
0010-E3-14
Condition Remarks
(a) While structurally intact, the case leather is wearing away from the wood; hinges suffering from inactive corrosion; one hinge is broken; inside, satin is stained and velvet has sustained significant fungus and insect damage; (b) some wear on metal but is still functional; (c-e) some tarnishing around base; (f,g) some wear; mirrors clean; (h) wear and discolouration near plug end; (i) eyepiece intact but worn; tarnished on inside of cylinder; (j) plate is slightly worn; (k) wear on blade; some tarnish on underside; (l) slight inactive corrosion on top rim; wear on front face; rotary mechanism still functional; (m) adhesive debris stuck to arm; wear along length; significant wear two cm back from light tip; (n) leather cover peeling; inactive corrosion throughout inside; threading broken and cracked; bottom of handle missing; #2: box: dirty overall; losses to covering, especially at edges and corners; coveirng lifting at both back corners and along bottom edges; satin lining stained and worn with tide-lines and discolouration of fabric; velvet lining very dusty with major loss around the narrow end of one of the depressions on PR; pin on hinge on PR partially removed from barrel and is very rusty; pin on hinge of PL is missing; implements: minor surface dirt and accretions; major corrosion on interior of (n) with resulting loss of surface coating; screw-on end of this tool part has major losses.
Copy Type
Original
Reference Types
Book
Other
Reference Comments
"American Hospital Supply Catalog (C30)," Div. of AHSC, Canada, 1964 (c-e) similar to 31230-020; (f,g) similar to 31490-010; (i) similar to disassembled 31226; (j) similar to part of 31217-005; (l) similar to 31210; (m) similar to 31455-025; (n) similar to 31335; see also 1979.12.7 and 1982.5.22
Research Facts
Museum has two similar ophthalmoscopes to (l): 1979.12.7 and 1982.5.22.
Exhibit History
McCord Museum in Montreal ("Growing Up in Montreal") from 26 Aug. 2004 to 22 June 2007; L-2004.3.
Images
Less detail

universal ear piercer

https://mhc.andornot.com/en/permalink/artifact9680
Collection
Dr. Burns Collection
Category
Surgery, Instrumentation
Classification
Surgery, instrumentation
Accession Number
995005062 a-q
Description
(a) Metal ear piercer with cylindrical body, "C"-shaped head, gull-wing extensions for the fingers just behind the head, and a circular plunger at the foot; (b) rectangular plastic snap case, with paper cards stuck in both top and bottom; (c) rectangular advertisement card for needles and heads; (d…
  4 images  
Accession Number
995005062 a-q
Collection
Dr. Burns Collection
Category
Surgery, Instrumentation
Classification
Surgery, instrumentation
MeSH Heading
Equipment and Supplies
Cosmetic Techniques -- instrumentation
Description
(a) Metal ear piercer with cylindrical body, "C"-shaped head, gull-wing extensions for the fingers just behind the head, and a circular plunger at the foot; (b) rectangular plastic snap case, with paper cards stuck in both top and bottom; (c) rectangular advertisement card for needles and heads; (d) rectangular folded paper sheet of additional instructions; (e) square plastic snapcase that holds (f-q); (f-i) cylindrical plastic slugs; (j-q) metal piercing pins; each pin is a cylindrical metal head attached to a thin pin.
Number Of Parts
17
Part Names
a - ear piercer - Size: Length 12.5 cm x Width 4.6 cm x Depth 1.6 cm
b - plastic case - Size: Length 14.4 cm x Width 7.1 cm x Depth 1.8 cm
c - card - Size: Length 6.9 cm x Width 4.7 cm
d - instructions - Size: Length 10.8 cm x Width 6.8 cm
e - pin case - Size: Length 3.6 cm x Width 2.9 cm x Depth 0.9 cm
f - plastic head - Size: Depth 0.6 cm x Diam. 0.4 cm
g - plastic head - Size: Depth 0.6 cm x Diam. 0.4 cm
h - plastic head - Size: Depth 0.6 cm x Diam. 0.4 cm
i - plastic head - Size: Depth 0.6 cm x Diam. 0.4 cm
j - piercing pin - Size: Depth 1.6 cm x Diam. 0.4 cm
k - piercing pin - Size: Depth 1.6 cm x Diam. 0.4 cm
l - piercing pin - Size: Depth 1.6 cm x Diam. 0.4 cm
m - piercing pin - Size: Depth 1.6 cm x Diam. 0.4 cm
n - piercing pin - Size: Depth 1.6 cm x Diam. 0.4 cm
o - piercing pin - Size: Depth 1.6 cm x Diam. 0.4 cm
p - piercing pin - Size: Depth 1.6 cm x Diam. 0.4 cm
q - piercing pin - Size: Depth 1.6 cm x Diam. 0.4 cm
Provenance
Owned and used by Dr. Burns of Napanee, Ont., a 1947 graduate of the Queen's University Medical Program; some items belonged to Dr. Stratton, who held the Napanee practice prior to Dr. Burns.
Maker
Goodrich–Universal Inc.
Site Made (City)
Saint Paul
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Material
paper: white; off-white; light blue
metal: silver
plastic: clear; white
Inscriptions
(a) Engraved on cylinder: "GOODRICH // UNIVERSAL INSTRUMENTS CO. // ST. PAUL MINN."; (b) printed on top cover, outside: "GOODRICH–UNIVERSAL INC. // 500 NO. ROBERT ST. // ST. PAUL. MINN. 55101 // UNIVERSAL // EAR // PIERCER"; printed on top cover, inside: "UNIVERSAL EAR PIERCER // "DIRECTIONS" // [directions listed] // Guarantee: If at any time the Universal Ear Piercer does not function properly, return it to us and it will be // replaced at no charge. This guarantee only applies when genuine Goodrich–Universal needles and heads are // used. The use of needles and heads from other manufacturers voids this guarantee. // Additional needles and pin heads (@ $5.00 per doz.) available from your favorite supplier // or direct from: // GOODRICH–UNIVERSAL INC. // MANUFACTURERS OF PRECISION INSTRUMENTS // 500 ROBERT STREET . SAINT PAUL, MINNESOTA 55101"; printed on inside of bottom cover: "RECOMMENDED STERILIZATION TECHNIQUES: // AUTOCLAVE @ 260° F // COLD SOLUTIONS — Mephane, Bard–Parker Gerlmicide, Metaphene, // Lehn and Fink Instrument Germicide // DOO NOT USE: Zephiran, any mercuric derivatives // GOODRICH UNIVERSAL, INC. // 500 N. Robert Street // St. Paul, Minnesota 55101"; bottom cover, outside is identical to bottom cover, inside; (c) printed on both sides: "One Dozen No. 200 // NEEDLES and HEADS // for the // UNIVERSAL EAR PIERCER // For Best Results, Use Needles and Heads // Only Once // [guarantee identical to that on (b) listed] // GOODRICH–UNIVERSAL, INC. // 500 No. Robert St. St. Paul, Minn. 55101"; (d) printed on front side: "Do not store instrument for prolonged periods in // solutions containing anti-rust chemicals. // Do not autoclave plastic heads above 260° F. // Best results are obtained by using needles and plastic heads only once. // GOODRICH UNIVERSAL, INC. // 500 No. Robert Street // St. Paul, Minnesota 55101 // Form No. 800"; printed on reverse side: "WARNING // THE USE OF NEEDLES AND HEADS OTHER THAN // THOSE MANUFACTURED BY GOODRICH–UNIVERSAL // MAY CAUSE THIS UNIVERSAL EAR PIERCER TO JAM OR OTHERWISE MALFUNCTION."
Permanent Location
Storage Room 0010
0010-C3-10
Condition Remarks
(a) tarnish on head, on inside curve of "C" shape; (b) cracks in case, but structurally sound; grimy; (c) slightly faded; (d) paper stained; (e) light wear; small crack in bottom; (f-i) some wear; (j-q) little wear.
Copy Type
Original
Reference Types
JPG
Reference Comments
CD #9
Images
Less detail

capsular forceps

https://mhc.andornot.com/en/permalink/artifact9623
Dates
1950
1960
circa 1950-1960
Collection
Dr. Burns Collection
Category
Diagnostic & Treatment Artifacts
Physical Examination
Surgery
Surgery, Instrumentation
Classification
Ophthalmology
Diagnosis, Eyes
Surgery
Surgery, instrumentation
Vision
Physical Examination
Accession Number
995005078
Description
Forceps with a curved neck with large and small convex bends; arms are grooved to allow for good grip.
  1 image  
Accession Number
995005078
Collection
Dr. Burns Collection
Category
Diagnostic & Treatment Artifacts
Physical Examination
Surgery
Surgery, Instrumentation
Classification
Ophthalmology
Diagnosis, Eyes
Surgery
Surgery, instrumentation
Vision
Physical Examination
MeSH Heading
Hemostasis, Surgical -- instrumentation
MM= Grasping and Fixating -- forceps
Ophthalmology
Diagnosis, Eyes
Surgery
Surgery, instrumentation
Vision
Physical Examination
Description
Forceps with a curved neck with large and small convex bends; arms are grooved to allow for good grip.
Number Of Parts
1
Provenance
Owned and used by Dr. Burns of Napanee, Ont., graduate of the Queen's University Faculty of Medicine Class of 1947; some items belonged to Dr. Stratton, who held the Napanee practice prior to Dr. Burns.
Maker
Jetter & Scheerer
Site Made (Country)
Germany
Dates
1950
1960
circa 1950-1960
Material
metal: silver
Inscriptions
Engraved on the face of the forceps is the Jetter & Scheerer logo of a caduceus rod topped by a crown, with text below: "STAINLESS"; on the reverse: "JETTER & SCHEERER // GERMANY"
Permanent Location
Storage Room 0010
0010-D3-1
Dimension Notes
Length 14.3 cm x Width 1.1 cm x Depth 3.1 cm
Condition Remarks
Small amounts of tarnish and inactive corrosion visible
Copy Type
Original
Reference Types
Book
Reference Comments
"Illustrations of Surgical Instruments of Superior Quality, 21st ed." Kny-Scheerer Co., ca. 1915, p. 3010 (similar to item C/-647)
Research Facts
For use in eye operations
Images
Less detail

surgical instrument tray

https://mhc.andornot.com/en/permalink/artifact9625
Dates
1947
circa 1947
Collection
Dr. Burns Collection
Category
Surgery, Instrumentation
Classification
Surgery, instrumentation
Accession Number
995005080
Description
An enamelware tray and cover used to hold instruments and catheters; the two pieces are rectangular and have rolled rims; the tray has a flat base and straight walls with rounded edges; the cover has a convex lid with a curved handle.
  2 images  
Accession Number
995005080
Collection
Dr. Burns Collection
Category
Surgery, Instrumentation
Classification
Surgery, instrumentation
MeSH Heading
Equipment and Supplies, Hospital
MM= Catheterization -- accessories
Description
An enamelware tray and cover used to hold instruments and catheters; the two pieces are rectangular and have rolled rims; the tray has a flat base and straight walls with rounded edges; the cover has a convex lid with a curved handle.
Number Of Parts
2
Part Names
a - tray - Size: Length 43.1 cm x Width 10.2 cm x Depth 4.3 cm
b - cover - Size: Length 43.7 cm x Width 10.8 cm x Depth 3.9 cm
Provenance
Owned and used by Dr. Burns of Napanee, Ont., a 1947 graduate of the Queen's University Medical Program; some items belonged to Dr. Stratton, who held the Napanee practice prior to Dr. Burns.
Dates
1947
circa 1947
Date Remarks
Based on collection dates
Material
enamelware: white
Inscriptions
None
Permanent Location
Storage Room 0010
0010-D3-5
Condition Remarks
Very slight chipping inside rim of cover
Copy Type
Original
Reference Types
Book
JPG
Reference Comments
"Hospital & Physicians Equipment and Supplies," by J.F. Hartz Co., 1960, p. 268 (item# 7H-368 B) (see attached photocopy); CD #9
Images
Less detail

instrument tray

https://mhc.andornot.com/en/permalink/artifact9701
Dates
1960
circa 1960
Collection
Dr. Burns Collection
Category
Diagnostic & Treatment Artifacts
Surgery, Instrumentation
Classification
Treatment, General
Surgery, instrumentation
Accession Number
995005093
Description
Rectangular enamelled metal instrument tray with flared sides and rolled lip.
  1 image  
Accession Number
995005093
Collection
Dr. Burns Collection
Category
Diagnostic & Treatment Artifacts
Surgery, Instrumentation
Classification
Treatment, General
Surgery, instrumentation
MeSH Heading
Equipment and Supplies, Hospital
Description
Rectangular enamelled metal instrument tray with flared sides and rolled lip.
Number Of Parts
1
Provenance
Owned and used by Dr. Burns of Napanee, Ont., a 1947 graduate of the Queen's University Medical Program; some items belonged to Dr. Stratton, who held the Napanee practice prior to Dr. Burns.
Maker
Hygienic
Site Made (Country)
Austria
Dates
1960
circa 1960
Date Remarks
Date based on catalogue
Material
metal: dark grey
enamel: white; blue
Inscriptions
Printed on bottom: "HYGIENIC // [Red Cross symbol] // AUSTRIA // [illeg.] // 30"
Permanent Location
Storage Room 0010
0010-D3-4
Dimension Notes
Length 31.5 cm x Width 19.4 cm x Depth 5.5 cm
Condition Remarks
Spots of inactive corrosion over surface; enamel is chipped; two deep scratches and persistent stains on floor of tray; damage is superficial.
Copy Type
Original
Reference Types
Book
JPG
Reference Comments
"Hospital & Physicians Equipment and Supplies," by J.F. Hartz Co., 1960, p. 268 (similar to item #7H-374-B) (see attached photocopy); CD #1
Images
Less detail
Dates
1955
circa 1955
Collection
Dr. Burns Collection
Category
Diagnostic & Treatment Artifacts
Surgery, Instrumentation
Classification
Treatment, General
Surgery, instrumentation
General Surgery
Accession Number
995005121
Description
Two-tiered stainless steel metal table on four casters.
  1 image  
Accession Number
995005121
Collection
Dr. Burns Collection
Category
Diagnostic & Treatment Artifacts
Surgery, Instrumentation
Classification
Treatment, General
Surgery, instrumentation
General Surgery
MeSH Heading
Equipment and Supplies, Hospital
Description
Two-tiered stainless steel metal table on four casters.
Number Of Parts
1
Provenance
Owned by Dr. Burns of Napanee, Ontario.
Dates
1955
circa 1955
Date Remarks
Temporary receipt in donor file indicates table is "turn of the century"; but table appears more recent based on appearance; resembles a model in catalogue from 1957
Material
metal: silver
rubber: black
wood: brown
paint: silver
Inscriptions
Handwritten in crayon on underside of table: "Dec 15 // OK // MAR 30, 1967 "
Permanent Location
Storage Room W1
W1-2-2
Dimension Notes
Length 91.5 cm x Width 91.5 cm x Depth 61.0 cm
Condition Remarks
Scratched throughout; light rusting on legs; metallic coating is flaking and exposing rust; rubber wheels are worn; countertops have dents.
Copy Type
Original
Reference Types
Book
JPG
Reference Comments
"Allen and Hanburys Ltd Catalogue," 1957, p. 27 (similar to model 12436); CD #5.
Research Facts
Used as an instrument table, possibly in an operating room
Images
Less detail
Dates
1921
circa 1921
Collection
Dr. Clifford W. Bennett Collection
Category
Diagnostic & Treatment Artifacts
Surgery, Instrumentation
Classification
Diagnosis, General
Treatment, General
Surgery, instrumentation
General Surgery
Accession Number
995006001 a-u
Description
A black leather doctor's bag; the bag (a) has two handles and seals with a zipper; the bag contains an envelope (b) containing an Adam's brand lancet (c), a leather adrenaline ampoule box (d) containing a corroded scalpel blade (e), a cardboard coramine box (f) containing a package of scalpel blad…
  1 image  
Accession Number
995006001 a-u
Collection
Dr. Clifford W. Bennett Collection
Category
Diagnostic & Treatment Artifacts
Surgery, Instrumentation
Classification
Diagnosis, General
Treatment, General
Surgery, instrumentation
General Surgery
MeSH Heading
House Calls
MM= Medical Case -- bag
Description
A black leather doctor's bag; the bag (a) has two handles and seals with a zipper; the bag contains an envelope (b) containing an Adam's brand lancet (c), a leather adrenaline ampoule box (d) containing a corroded scalpel blade (e), a cardboard coramine box (f) containing a package of scalpel blades (g), a leather case made by The Stevens Companies (h) containing a scalpel handle (i) and 10 scalpel blades of different sizes and shapes (j-s) some of which are wrapped in green paper, and a blue package of disposable B-D blood lancets (t) with five lancets inside sealed in a single metal strip (u).
Number Of Parts
21
Part Names
a - bag - Length 47.0 cm x Width 20.0 cm x Depth 19.4 cm
b - envelope - Length 16.5 cm x Width 9.2 cm
c - lancet - Length 12.0 cm x Width 0.9 cm x Depth 1.1 cm
d - adrenaline box - Length 7.3 cm x Width 6.7 cm x Depth 1.6 cm
e - scalpel blade - Length 5.0 c x Width 0.6 cm x Depth 0.1 cm
f - coramine box - Length 6.1 cm x Width 4.7 cm x Depth 1.7 cm
g - scalpel blade package - Length 5.8 cm x Width 2.8 cm x Depth 1.7 cm
h - leather case - Length 16.8 cm x Width 5.8 cm x Depth 1.0 cm
i - scalpel handle - Length 13.5 cm x Width 1.1 cm x Depth 0.5 cm
j - scalpel blade - Length 5.8 cm x Width 1.0 cm x Depth 0.1 cm
k - scalpel blade - Length 6.0 cm x Width 1.0 cm x Depth 0.1 cm
l-r - scalpel blade - Length 7.0 cm x Width 1.8 cm x Depth 0.1 cm
s - scalpel blade - Length 6.0 cm x Width 2.7 cm x Depth 0.1 cm
t - lancet package - Length 11.8 cm x Width 6.1 cm x Depth .01 cm
u - lancets - Length 9.0 cm x Width 5.6 cm x Depth 0.1 cm
Provenance
Owned and used by Dr. Clifford. W. Bennett.
Maker
Cheney
Site Made (Country)
England
Dates
1921
circa 1921
Date Remarks
Dr. Bennett graduated in 1921.
Material
leather: black
cardboard: green, blue
metal: silver
paper: green, white
Inscriptions
"C.W.B." printed on the side of the case in gold letters; "Dr. C. W. Bennett, // 197 Queen Street, // Kingston, Ontario." and DR. D. L. C. BINGHAM // ETHERINGTON HALL // STUART STREET // KINGSTON, ONTARIO" typed on the envelope with "KINGSTON // 930 PM // 132 VIIIII // 1964 // ONTARIO" stamped on it
Permanent Location
Storage Room 0010
0010-C1-6
(f) 0010-A3-3 Row D
Condition Remarks
The leather on the case has become very hard; some of the leather and paper have degraded.
Reference Types
JPG
Reference Comments
CD #7
Research Facts
Dr. Bennett graduated from Queen's Meds in 1921. He was a general practitioner in Kingston and practiced medicine at 197 Queen St; He practiced from 1925 until his death in 1964; he had a certificate in obstetrics.
Images
Less detail

Desmarres eyelid retractor

https://mhc.andornot.com/en/permalink/artifact4878
Dates
1930
1950
circa 1930-1950
Collection
McPherson Collection
Category
Diagnostic & Treatment Artifacts
Physical Examination
Surgery
Surgery, Instrumentation
Vision
Classification
Ophthalmology
Diagnosis, Eyes
Surgery
Surgery, instrumentation
Vision
Physical Examination
Accession Number
997003025
Description
Desmarre's eyelid retractor, which consists of a long, narrow squared handle that is tapered slightly at both ends; the operator end is squared off and closed; the other end attaches to the blade; the blade has a long, narrow rounded section that ends in a large, oval piece that has been folded dow…
  1 image  
Accession Number
997003025
Collection
McPherson Collection
Category
Diagnostic & Treatment Artifacts
Physical Examination
Surgery
Surgery, Instrumentation
Vision
Classification
Ophthalmology
Diagnosis, Eyes
Surgery
Surgery, instrumentation
Vision
Physical Examination
MeSH Heading
Dilatation
Physical Examination
Ophthalmology
Diagnosis, Eyes
Surgery
Surgery, instrumentation MM= Dilatation -- speculum -- eye
Vision
MM= Grasping and Fixating -- retractor -- lid
Description
Desmarre's eyelid retractor, which consists of a long, narrow squared handle that is tapered slightly at both ends; the operator end is squared off and closed; the other end attaches to the blade; the blade has a long, narrow rounded section that ends in a large, oval piece that has been folded down in a rounded 90° angle; the outer edge of the tip is rounded.
Number Of Parts
1
Provenance
Owned and used by Dr. Malcolm E. McPherson, a graduate of Queen's School of Medicine in 1929; Dr. McPherson practised in Hawthorne, NS; he was a G.P. but specialized in gynecology.
Dates
1930
1950
circa 1930-1950
Material
metal: silver; light grey
Inscriptions
None
Permanent Location
Storage Room 0010
0010-E4-10
Dimension Notes
Length 13.9 cm x Width 1.4 cm x Depth 1.2 cm
Condition Remarks
The metal shows some wear; the handle has very small dark spots visible; no corrosion is visible.
Copy Type
Original
Reference Types
Book
Person
Reference Comments
Ms. Lyall McPherson (daughter); "Aesculap Jetter & Scheerer Surgical Instruments," Canada edition, c. 1960, p. 197; similar to 997.003.026
Research Facts
McPherson practised 1931–1957
Images
Less detail

Desmarres eyelid retractor

https://mhc.andornot.com/en/permalink/artifact4879
Dates
1930
1950
circa 1930-1950
Collection
McPherson Collection
Category
Diagnostic & Treatment Artifacts
Physical Examination
Surgery
Surgery, Instrumentation
Vision
Classification
Ophthalmology
Diagnosis, Eyes
Surgery
Surgery, instrumentation
Vision
Physical Examination
Accession Number
997003026
Description
Desmarre's eyelid retractor, which consists of a long, narrow squared handle that is tapered slightly at both ends; the operator end is squared off and closed; the other end attaches to the blade; the blade has a long, narrow rounded section that ends in a large, oval piece that has been folded dow…
  1 image  
Accession Number
997003026
Collection
McPherson Collection
Category
Diagnostic & Treatment Artifacts
Physical Examination
Surgery
Surgery, Instrumentation
Vision
Classification
Ophthalmology
Diagnosis, Eyes
Surgery
Surgery, instrumentation
Vision
Physical Examination
MeSH Heading
Dilatation
Physical Examination
Ophthalmology
Diagnosis, Eyes
Surgery
Surgery, instrumentation
MM= Dilatation -- speculum -- eye
Vision
MM= Grasping and Fixating -- retractor -- lid
Description
Desmarre's eyelid retractor, which consists of a long, narrow squared handle that is tapered slightly at both ends; the operator end is squared off and closed; the other end attaches to the blade; the blade has a long, narrow rounded section that ends in a large, oval piece that has been folded down in a rounded 90° angle; the outer edge of the tip is rounded.
Number Of Parts
1
Provenance
Owned and used by Dr. Malcolm E. McPherson, a graduate of Queen's School of Medicine in 1929; Dr. McPherson practised in Hawthorne, NS; he was a G.P. but specialized in gynecology.
Maker
Chiron
Site Made (Country)
Germany
Dates
1930
1950
circa 1930-1950
Material
metal: silver
Inscriptions
The words "CHIRON GERMANY" are stamped into the handle on one side, at the operator end.
Permanent Location
Storage Room 0010
0010-E4-10
Dimension Notes
Length 13.3 cm x Width 1.1 cm x Depth 1.0 cm
Condition Remarks
The metal shows some wear; no corrosion is visible.
Copy Type
Original
Reference Types
Book
Person
Reference Comments
Ms. Lyall McPherson (daughter); "Aesculap Jetter & Scheerer Surgical Instruments," Canada edition, c. 1960, p. 197 (similar to item #02-342); similar to 997.003.025
Research Facts
McPherson practised 1931–1957
Images
Less detail

Stryker wedge frame

https://mhc.andornot.com/en/permalink/artifact11703
Dates
1970
circa 1970
Collection
Kingston General Hospital Collection
Category
Diagnostic & Treatment Artifacts
Surgery, Instrumentation
Classification
Surgery, instrumentation
Treatment, General
Accession Number
997019001 a-n
Description
Stryker wedge frame which consists of metal (a) wedge frame on four castors; the frame is "I" shaped with a main bar that supports two sliding wooden trays and hydraulic jack; cross bar on main bar supports one wooden tray and armature for the tray to slide along; two adjustable vertical bars exte…
  5 images  
Accession Number
997019001 a-n
Collection
Kingston General Hospital Collection
Category
Diagnostic & Treatment Artifacts
Surgery, Instrumentation
Classification
Surgery, instrumentation
Treatment, General
MeSH Heading
Transportation of Patients -- instrumentation
Description
Stryker wedge frame which consists of metal (a) wedge frame on four castors; the frame is "I" shaped with a main bar that supports two sliding wooden trays and hydraulic jack; cross bar on main bar supports one wooden tray and armature for the tray to slide along; two adjustable vertical bars extend from wheel-bearing cross bars to support stretcher; vertical bar supports rotating circular frame for clamp; circular frame includes handles; two (b-c) stretchers intersect circular frame and are held in place by clamp; stretchers are piled one over another and consist of metal frames covered in canvas with eyelets and spring bindings; stretchers contain plastic encased foam mattress; one stretcher includes a circular opening measuring approximately 6 inches; (d) separate canvas piece has eyelets and small circular opening; 2 fabric (e-f) belts have locking mechanisms; (g) vice with three screws; (h) rod with connectors extends vertically and loops at a right angle; the stretchers each separate into plastic covered foam (i,k,m) mattress pads and (j,l,n) cotton pad covers.
Number Of Parts
8
Part Names
a - wedge frame - Size: Length 1.58 m. x Width 1.16 m. x Depth 78.0 cm.
b - stretcher - Size: Length 2.17 m. x Width 53.0 cm. x Depth 16.0 cm.
c - stretcher - Size: Length 2.16 m. x Width 50.0 cm. x Depth 7.0 cm.
d - canvas piece - Size: Length 81.0 cm. x Width 36.7 cm. x Depth 0.5cm.
e - belt - Size: Length 1.92 m. x Width 6.2 cm. x Depth 2.0 cm.
f - belt - Size: Length 1.88 m. x Width 6.3 cm. Depth 1.8 cm.
g - vice - Size: Length 15.3 cm. x Width 11.5 cm. Depth 10.0 cm.
h - rod - Size: Length 31.6 cm. x Width 17.5 cm. x Depth 9.8 cm.
i - mattress pad - Size: Length 98.0 cm x Width 48.7 cm x Depth 3.0 cm.
j - cotton cover - Size: Length 92.6 cm x Width 58.5 cm x Depth 0.02 cm.
k - mattress pad - Size: Length 97.5 cm x Width 48.7 cm x Depth 3.0 cm.
l - cotton cover - Size: Length 99.0 cm x Width 62.0 cm x Depth 0.02 cm.
m - mattress pad - Size: Length 1.45 m x Width 50.5 cm x Depth 4.0 cm.
n - cotton cover - Size: Length 1.5 m x Width 62.0 cm x Depth 0.02 cm.
Provenance
Used at Kingston General Hospital, orthopedic
Maker
Stryker Corporation
Site Made (City)
Kalamazoo
Site Made (State)
Michigan
Site Made (Country)
United States of America
Dates
1970
circa 1970
Date Remarks
Date is printed on label affixed to artifact
Material
metal: black, grey
fabric: white, yellow
wood: brown
plastic: black, red ,white
paint: green
foam: light green
Inscriptions
Printed on sticker affixed to frame; "THE STRYKER WEDGE FRAME // CATALOGUE NO. 124 MODEL A // 1665 Stryker // CORPORATION // KALAMAZOO, MICHIGAN // U.S. PATENT NO. 3,302,218; CANADIAN PATENT NO. 836, 202, 1970 MADE IN U.S.A. // SURGICAL AND HOSPITAL EQUIPMENT"; printed on sticker affixed to jack: "WARNING // REMOVE SWING LEVER LOCK // BEFORE INSTALLING HYDRAULIC // JACK ASSEMBLY ON HEAD END // OFF WEDGE FRAME"; printed on sticker affixed to frame; "HOTEL D[Illeg.]"; printed on sticker affixed to frame: "WARNING // REMOVE PATIENT // BEFORE EXTENDING // FRAME"; printed on sticker affixed to circular frame for clamp: "CAUTION // NEVER COMPLETELY // REMOVE THIS BAR // THIS BAR MAY BE ADJUSTED TO PATIENTS THICKNESS. // SPACER NUTS MAY BE REMOVED FOR SPECIAL CASES. // ALWAYS TIGHTEN NUTS BEFORE ROTATING PATIENT."; printed on sticker affixed to circular frame for clamp: "ANTERIOR"; handwritten in pencil on tape affixed to circular frame for clamp: "4.211"; embroidered on fabric label affixed to stretcher canvas: "stryker // POST CANVAS // COVER // 125-4-5 // KALAMAZOO, MI // 124-4-7 REV_"; handwritten in marker on stretcher canvas: "WEDGE // STRYKER // PART"; printed on cotton sheet of stretcher: "Kingston General Hospital // Kingston Ontario"; handwritten in marker on cotton of stretcher: "KGH // STRYKER // POSTERIOR // SHEET"; handwritten on label affixed to belt: "KINGSTON GENERAL HOSPITAL // ORTHO EQP ROOM // STRYKER FRAME".
Permanent Location
Storage Room W1
W1-Floor
Condition Remarks
Metal frame tarnished and with light rust; minor scratches on frame; paint peeling from wooden tray; minor stains on stretcher canvas and cotton; metal frames of stretchers scuffed; fabric around circular opening of stretcher yellowed; rubber ring on frame of stretcher torn; canvas piece lightly stained in several locations; belts showing minor wear; vice screws scuffed and paint peeling; minor stains and residue on rod.
Copy Type
Original
Reference Types
Internet
JPG
Reference Comments
Stryker medical website, copy in donor file; CD #6.
Research Facts
Used for spinal injury treatment and surgery.
Images
Less detail

174 records – page 1 of 18.