Skip header and navigation

Refine By

   MORE
   MORE
   MORE
  • All Records

14354 records – page 1 of 1436.

pulse generator - demo model

https://mhc.andornot.com/en/permalink/artifact266
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007211
Description
Demonstrator model; internal pacemaker; rectangular shape; stainless steel; rubber attachment to top; with insert for wire; maker and model information engraved to front and back
Accession Number
994007211
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial -- models
Description
Demonstrator model; internal pacemaker; rectangular shape; stainless steel; rubber
attachment to top; with insert for wire; maker and model information engraved to
front and back
Number Of Parts
1
Maker
Telectronics
Site Made (City)
Sydney
Site Made (Country)
Australia
Material
metal: silver
rubber: white
Inscriptions
Engraved to front: TELECTRONICS // 150B S/N 310086; engraved to back: MODEL 150B VVI//
VENTRICULAR INHIBITED // PULSE GENERATOR // THIS SIDE UP // TELECTRONICS // SYDNEY
AUSTRALIA // NOT FOR IMPLANT
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 5.5 cm. x Width: 5.3 cm. x Depth: 1.5 cm.
Condition Remarks
2004: plastic detached from metal base
Copy Type
Other
Reference Types
Person
Reference Comments
Dr. Chiong
Exhibit History
"Pacemakers: Technology Development," HDH, 14 Feb. 2007
Less detail

pacemaker demo unit

https://mhc.andornot.com/en/permalink/artifact267
Dates
1980s
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007212
Description
Demonstrator model; internal pacemaker; curved shape; stainless steel; translucent rubber attachment to top; with insert for wire; maker and model information engraved to front and back.
Accession Number
994007212
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial -- models
Description
Demonstrator model; internal pacemaker; curved shape; stainless steel; translucent rubber attachment to top; with insert for wire; maker and model information engraved to front and back.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Telectronics
Site Made (City)
Milwaukee
Site Made (State)
Wisconsin
Site Made (Country)
United States of America
Dates
1980s
Material
metal: silver
rubber: clear
Inscriptions
Engraved to front: TELECTRONICS // MILWAUKEE WI USA // OPTIM - MP VVI/VOO // DEMO UNIT NO. 460 // 30
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 5.5 cm. x Width: 5.0 cm. x Depth: 0.9 cm.
Copy Type
Other
Less detail

pacemaker demo model

https://mhc.andornot.com/en/permalink/artifact268
Dates
1980s
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007213
Description
Demonstrator model; internal pacemaker; rectangular shape; stainless steel; insert to top for wire; maker and model information engraved to front.
Accession Number
994007213
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial -- models
Description
Demonstrator model; internal pacemaker; rectangular shape; stainless steel; insert to top for wire; maker and model information engraved to front.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Pacesetter Systems Inc.
Dates
1980s
Material
metal: silver
Inscriptions
Engraved to front: PACESETTER SYSTEMS INC. // PACEMAKER // MODEL UDL-100 RATE 71 // SERIAL NO. UDL-DEMO
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 7.3 cm. x Width: 4.3 cm. x Depth: 1.4 cm.
Copy Type
Other
Less detail

pacemaker demo model

https://mhc.andornot.com/en/permalink/artifact269
Dates
1980s
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007214
Description
Demonstrator model; internal pacemaker; oblong shape; stainless steel; plastic attachment to top; with inserts for wires to attachment; maker name and model information engraved to front and back of pacemaker.
  2 images  
Accession Number
994007214
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial -- models
Description
Demonstrator model; internal pacemaker; oblong shape; stainless steel; plastic attachment to top; with inserts for wires to attachment; maker name and model information engraved to front and back of pacemaker.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Medtronic
Site Made (City)
Mississauga
Site Made (State)
Ontario
Site Made (Country)
Canada
Dates
1980s
Material
metal: silver
Inscriptions
Engraved to front: MULTI-PROGRAMMABLE // PULSE GENERATOR // GL4000052M // MEDTRONIC CANADA // MISSISSAUGA ONT // CANADA; to back: NOT FOR HUMAN USE
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 6.0 cm. x Width: 4.2 cm. x Depth: 1.0 cm.
Copy Type
Other
Images
Less detail

Nova II pacemaker demo model

https://mhc.andornot.com/en/permalink/artifact270
Dates
1980
1990
circa 1980-1990
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007215
Description
Demonstration model; internal pacemaker; oblong shape; silver plastic unit; clear plastic attachment to top; with insert for wire to attachment; maker name and model information imprinted to front and back.
  2 images  
Accession Number
994007215
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial -- models
Description
Demonstration model; internal pacemaker; oblong shape; silver plastic unit; clear plastic attachment to top; with insert for wire to attachment; maker name and model information imprinted to front and back.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Intermedics Inc.
Site Made (City)
Freeport
Site Made (State)
Texas
Site Made (Country)
United States of America
Dates
1980
1990
circa 1980-1990
Material
plastic: silver; clear
Inscriptions
Imprinted to front: Intermedics Inc. // FREEPORT TEXAS // NOVA II // Model 282-04 // SSI SST SOO; imprinted to back: Not for Human Implant
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 5.0 cm. x Width: 3.7 cm. x Depth: 0.6 cm.
Copy Type
Other
Exhibit History
May 24 - Sept. 13, 2001: Agnes Etherington Art Centre Museopathy exhibit
Images
Less detail

Enertrax internal pacemaker demonstration model

https://mhc.andornot.com/en/permalink/artifact271
Dates
1965
1975
circa 1965-1975
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007216
Description
Demonstration model; internal pacemaker; oblong shape; stainless steel; with translucent plastic attachment to top; insert for wire to attachment; maker and model information imprinted to front and back.
  2 images  
Accession Number
994007216
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial -- models
Description
Demonstration model; internal pacemaker; oblong shape; stainless steel; with translucent plastic attachment to top; insert for wire to attachment; maker and model information imprinted to front and back.
Number Of Parts
1
Maker
Medtronic
Dates
1965
1975
circa 1965-1975
Material
metal: silver
plastic: clear
Inscriptions
Imprinted to front: "Enertrax™ // Atrial Synchronous; to back: SXT // SPECTRAX // by Medtronic"
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 6.0 cm. x Width: 4.6 cm. x Depth: 1.0 cm.
Copy Type
Other
Images
Less detail

Spectrax-SX pacemaker demo model

https://mhc.andornot.com/en/permalink/artifact272
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007217
Description
Demonstration model; internal pacemaker; oblong shape; stainless steel; with translucent plastic attachment to top; insert for wire to attachment; maker and model information imprinted to front and back
Accession Number
994007217
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial -- models
Description
Demonstration model; internal pacemaker; oblong shape; stainless steel; with translucent
plastic attachment to top; insert for wire to attachment; maker and model information
imprinted to front and back
Number Of Parts
1
Maker
Medtronic
Material
metal: silver
plastic: clear
Inscriptions
To front: SPECTRAX-SX // For the Spectrum of // Pacing Applications; to back:
SPECTRAX-SX // by Medtronic
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 6.0 cm. x Width: 4.6 cm. x Depth: 1.0 cm.
Copy Type
Other
Reference Types
Person
Reference Comments
Dr. Chiong
Exhibit History
May 24 - Sept. 13, 2001: Agnes Etherington Art Centre Museopathy exhibit
Less detail

Versatrax II pacemaker demo model

https://mhc.andornot.com/en/permalink/artifact273
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007218
Description
Demonstration model; internal pacemaker; oblong shape; stainless steel; with translucent plastic attachment to top; insert for wire to attachment; maker and model information imprinted to front and back
Accession Number
994007218
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial -- models
Description
Demonstration model; internal pacemaker; oblong shape; stainless steel; with translucent
plastic attachment to top; insert for wire to attachment; maker and model information
imprinted to front and back
Number Of Parts
1
Maker
Medtronic
Material
metal: silver
plastic: clear
Inscriptions
To front: "Versatrax II™"; to back:" Versatrax II™ // by Medtronic"
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 6.0 cm. x Width: 5.3 cm. x Depth: 1.0 cm.
Copy Type
Other
Reference Types
Person
Reference Comments
Dr. Chiong
Less detail

Versatrax II pacemaker demo model

https://mhc.andornot.com/en/permalink/artifact274
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007219
Description
Demonstration model; internal pacemaker; oblong shape; stainless steel; with translucent plastic attachment to top; insert for wire to attachment; maker and model information imprinted to front and back
Accession Number
994007219
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial -- models
Description
Demonstration model; internal pacemaker; oblong shape; stainless steel; with translucent
plastic attachment to top; insert for wire to attachment; maker and model information
imprinted to front and back
Number Of Parts
1
Maker
Medtronic
Material
metal: silver
plastic: clear
Inscriptions
To front: "Versatrax II™"; to back: "Versatrax II™ // by Medtronic"
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 6.0 cm. x Width: 5.3 cm. x Depth: 1.0 cm.
Copy Type
Other
Reference Types
Person
Reference Comments
Dr. Chiong
Exhibit History
May 24 - Sept. 13, 2001: Agnes Etherington Art Centre Museopathy exhibit
Less detail

Mirel pulse generator demo model

https://mhc.andornot.com/en/permalink/artifact275
Dates
1980
1990
circa 1980-1990
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007220
Description
Demonstration model; internal pacemaker; circular shape; stainless steel; with plastic attachment to top; insert for wire to attachment; maker and model information imprinted to front and back.
  1 image  
Accession Number
994007220
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial -- models
Description
Demonstration model; internal pacemaker; circular shape; stainless steel; with plastic attachment to top; insert for wire to attachment; maker and model information imprinted to front and back.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Medtronic
Dates
1980
1990
circa 1980-1990
Material
metal: silver
plastic: clear
Inscriptions
To front: MIREL // LITHIUM POWERED // PULSE GENERATORS // BY // MEDTRONIC
Permanent Location
Storage Room 0010
0010-E6-1
Dimension Notes
Length: 5.0 cm. x Width: 5.5 cm. x Depth: 1.0 cm.
Copy Type
Other
Exhibit History
May 24 - Sept. 13, 2001: Agnes Etherington Art Centre Museopathy exhibit
Images
Less detail

14354 records – page 1 of 1436.