Midget Kinet-o-Meter machine

https://mhc.andornot.com/en/permalink/artifact14382
Dates
1940
1950
circa 1940-1950
Collection
Canadian Anesthesiology Society
Category
Diagnostic & Treatment Artifacts
Classification
Anaesthesia
Accession Number
015016001
Description
Portable Midget Kinet-o-Meter machine used to administer dental anesthesia consists of four wheel stand with a pole with an adjustable swivel chart stand support attached, four cylinder yokes and a set of three flow meter panels are mounted to top of pole; gas cylinder yokes are arranged in sets of…
  3 images  
Accession Number
015016001
Collection
Canadian Anesthesiology Society
Category
Diagnostic & Treatment Artifacts
Classification
Anaesthesia
MeSH Heading
Anesthesia, Dental
Anesthesia, Inhalation
Anesthesia, Inhalation -- instrumentation
Anesthesiology, instrumentation
Description
Portable Midget Kinet-o-Meter machine used to administer dental anesthesia consists of four wheel stand with a pole with an adjustable swivel chart stand support attached, four cylinder yokes and a set of three flow meter panels are mounted to top of pole; gas cylinder yokes are arranged in sets of two with each yoke having a corresponding round knob; two knobs are marked O2 and the other two are marked N2O; set of three flow meter panels with glass covers marked in white font: cyclopropane with yellow background, middle is Nitrous oxide with dark blue background, oxygen with green background; without tanks.
Number Of Parts
1
Maker
The Ohio Chemical & Manufacturing Company
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1940
1950
circa 1940-1950
Date Remarks
Donor information
Material
metal: silver paper: yellow, blue, green, orange rubber: black
Inscriptions
Stamped onto a round metal plate behind the flow meter panel: "MIDGET KINET-O-METER // HIDBRINK DIVISION // THE OHIO CHEMICAL & MFG. CO. // MINNEAPOLIS, MINN.''; "MADE IN U. S. A. // PATENTS 1,412,866 // 1,500,615 1,802,601 1,1989,366 // 2,073,372 2,085,155". Below the oxygen flow meter panel and around the cylidrical pipe that comes out of it there is a yellowing paper band with the following printed on it: "WARNING; this equipm[illeg.] use only by // or under the super[illeg.] cian or dentist // Read instructions caref[illeg.] so[illeg.]ecome thoroughly // fam[illeg] with proper method [illeg] operation // Mfd. by THE OHIO CHEMICAL & MFG. CO."; stamped on the metal bar below the flow meter panel: K11050
Permanent Location
W2 538 Floor
Length
64.0 cm
Height
98.0 cm
Unit Of Measure
centimeters
Dimension Notes
Length measured from protruding opposite wheels
Copy Type
original
Reference Types
Internet
Reference Comments
https://en.wikipedia.org/wiki/Cyclopropane https://www.britannica.com/science/cyclopropane
Research Facts
Cyclopropane is an anaesthetic when inhaled. In modern anaesthetic practice, it has been superseded by other agents, due to its extreme reactivity under normal conditions: when the gas is mixed with oxygen, there is a significant risk of explosion. Cyclopropane had no commercial application until Henderson and Lucas discovered its anaesthetic properties in 1929; industrial production had begun by 1936. This meant induction of anaesthesia by inhalation of cyclopropane and oxygen was rapid and not unpleasant. However at the conclusion of prolonged anaesthesia patients could suffer a sudden decrease in blood pressure, potentially leading to cardiac dysrhythmia; a reaction known as "cyclopropane shock".For this reason, as well as its high cost and its explosive nature, it was latterly used only for the induction of anaesthesia, and has not been available for clinical use since the mid 1980s. Cylinders and flow meters were coloured orange. Cyclopropane, also called trimethylene, explosive, colourless gas used in medicine since 1934 as a general anesthetic. Cyclopropane is nonirritating to mucous membranes and does not depress respiration. Induction of and emergence from cyclopropane anesthesia are usually rapid and smooth. A mixture of about 5 to 20 percent cyclopropane in oxygen is administered by inhalation. Because of the flammability and expense of cyclopropane, it is usually used in a closed (rebreathing) system, in which an absorbent chemical, such as soda lime, removes exhaled carbon dioxide, and the anesthetic is recirculated. The chemical formula is C3H6.
Images
Less detail

pulse width controller

https://mhc.andornot.com/en/permalink/artifact58
Dates
1960
1970
circa 1960-1970
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007003
Description
Circular cream plastic pacemaker pulse width controller.
  2 images  
Accession Number
994007003
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Cardiac Pacing, Artificial -- instrumentation
Cardiology -- instrumentation
Description
Circular cream plastic pacemaker pulse width controller.
Number Of Parts
1
Provenance
Used on KGH patients
Maker
Medtronic
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1960
1970
circa 1960-1970
Material
plastic: cream
Inscriptions
"MEDTRONIC™ // 5531 PULSE WIDTH CONTROLLER // Medtronic, Inc. // MINNEAPOLIS, MINNESOTA U.S.A. // MODEL NO 5531 VOLTS // SER NO 3BN0501 CPS"
Permanent Location
Storage Room 0007
0007-J2-5
Dimension Notes
Depth 12.5 cm. x Diam. 14.0 cm.
Condition Remarks
remnants of adhesive from masking tape; #2: plastic yellowed
Reference Types
JPG
Reference Comments
CD #6
Images
Less detail

pacemaker rate controller

https://mhc.andornot.com/en/permalink/artifact60
Dates
1970
1993
circa 1970-1993
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007005
Description
Hand-held bright blue plastic Medtronics 9600 rate controller for pacemakers; lift of paper face plate has different readings than original
  2 images  
Accession Number
994007005
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Cardiac Pacing, Artificial -- instrumentation
Cardiology -- instrumentation
Description
Hand-held bright blue plastic Medtronics 9600 rate controller for pacemakers;
lift of paper face plate has different readings than original
Number Of Parts
1
Part Names
a - paper faceplate - Size: Length 8.0 cm. x Width 8.0 cm.
Provenance
Used on patients at KGH
Maker
Medtronics
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1970
1993
circa 1970-1993
Material
plastic: bright blue; white; black
metal: silver; black
paper: black; white
Inscriptions
MEDTRONIC (R) 9600 // RATE CONTROLLER // MINNEAPOLIS, MINNESOTA USA // 142471-001
Permanent Location
Storage Room 0007
0007-J2-4
Dimension Notes
Length 21.5 cm. x Width 9.8 cm. x Depth 8.0 cm.
Condition Remarks
shows wear
Reference Types
JPG
Reference Comments
CD #6
Images
Less detail

Medtronics pacemaker reference chart

https://mhc.andornot.com/en/permalink/artifact78
Dates
1987
1993
circa 1987-1993
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007023
Description
Two large instructional charts; "Medtronics Pacemaker Reference Chart" is stapled across the top
Accession Number
994007023
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial -- pictorial works
Cardiac Pacing, Artificial -- pictorial works
Description
Two large instructional charts; "Medtronics Pacemaker Reference Chart" is stapled
across the top
Number Of Parts
1
Provenance
Used by KGH doctors
Maker
Medtronics
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1987
1993
circa 1987-1993
Material
paper: white; bright blue; bright pink; green; black
Inscriptions
Medtronic // PACEMAKER REFERENCE CHART // April 1987 // MC 832003B // Copyright (C) 1987
by Medtronic, Inc. // All Rights Reserved // Printed in U.S.A. // Medtronic, Inc. //
7000 Central Avenue N.E. // Minneapolis, MN 55432 USA // 800/328-2518
Permanent Location
Storage Room 2005
2005-2-1
Dimension Notes
Length 82.5 cm. x Width 68.0 cm.
Less detail

Chardack-Greatbatch pacemaker

https://mhc.andornot.com/en/permalink/artifact82
Dates
1960
circa 1960
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007027
Description
Implantable pacemaker; circular structure; silicon rubber casing; with three rubber-encased wires extending from; maker's name imprinted on rubber casing of front surface.
  2 images  
Accession Number
994007027
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Implantable pacemaker; circular structure; silicon rubber casing; with three rubber-encased wires extending from; maker's name imprinted on rubber casing of front surface.
Number Of Parts
1
Maker
Medtronic
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1960
circa 1960
Date Remarks
Dr. Chiong's estimate
Material
rubber: white
metal: silver
Inscriptions
Imprinted on rubber casing: CHARDACK - GREATBATCH // PACEMAKER // MFGD BY // MPLS.MINN.USA
Permanent Location
Storage Room 0010
0010-E6-2
Temporary Location
Deaccessioned 2013
Dimension Notes
Length: 8.3 cm. x Width: 7.0 cm. x Depth: 2.5 cm. x Diam. : 6.8 cm. x Weight: 170.0 g.
Copy Type
Original
Reference Types
Person
Reference Comments
Dr. Chiong
Research Facts
Five cells; adjustable rate and current
Exhibit History
Pacemaker Exhibit - KGH Cardiology Dec. 1994
Images
Less detail

Chardack-Greatbatch pacemaker

https://mhc.andornot.com/en/permalink/artifact83
Dates
1960
circa 1960
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007028
Description
Implantable pacemaker; rough circular form with two sets of leads and mechanics visible; encased in cream-coloured rubber; two wire input tubes extending from bottom; one marked '+' and the other '-'; maker's name and mark imprinted to front surface.
  3 images  
Accession Number
994007028
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Implantable pacemaker; rough circular form with two sets of leads and mechanics visible; encased in cream-coloured rubber; two wire input tubes extending from bottom; one marked '+' and the other '-'; maker's name and mark imprinted to front surface.
Number Of Parts
1
Provenance
Collection was assembled over many years by Dr. R.O. West in the Division of Cardiology and Cardiology Laboratories at Kingston General Hospital.
Maker
Medtronic
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1960
circa 1960
Date Remarks
Dr. Chiong's estimate
Material
rubber: cream
metal: silver
Inscriptions
To front surface: CHARDACK GREATBATCH // PACEMAKER // MEDTRONIC // USA
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 6.8 cm. x Width: 6.5 cm. x Depth: 2.4 cm.
Condition Remarks
Overall condition good; #2: small gouge on front.
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #7
Research Facts
Weight: 165.0 g.
Exhibit History
Pacemaker Exhibit, KGH Cardiology, Dec. 1994
Images
Less detail

Chardack-Greatbatch pacemaker

https://mhc.andornot.com/en/permalink/artifact84
Dates
1960
1969
circa 1960-1969
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007029
Description
Internal pacemaker; rough circular form; inner mechanics visible; encased in a yellow transparent rubber; two wire input tubes extending from bottom, one marked '+', the other '-'; closed protrusion to side; maker's name and mark imprinted to front surface in white
  2 images  
Accession Number
994007029
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rough circular form; inner mechanics visible; encased in
a yellow transparent rubber; two wire input tubes extending from bottom, one
marked '+', the other '-'; closed protrusion to side; maker's name and mark
imprinted to front surface in white
Number Of Parts
1
Maker
Medtronic
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1960
1969
circa 1960-1969
Date Remarks
Dr. Chiong's estimate
Material
rubber: transparent; yellow
metal: silver
Inscriptions
To front: CHARDACK GREATBATCH // PACEMAKER // MEDTRONIC // USA
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 8.0 cm. x Width: 7.0 cm. x Depth: 2.5 cm. x Weight: 179.0 g.
Condition Remarks
overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #1
Exhibit History
“On loan L-2016-4” to the College of Physicians and Surgeons of Ontario’s 150th Anniversary exhibit; 30 April-8 July, 2016 Pacemaker Exhibit - KGH Cardiology Dec. 1994
Images
Less detail

Chardack pulse generator

https://mhc.andornot.com/en/permalink/artifact88
Dates
1970
circa 1970
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007033
Description
Circular structure implantable pacemaker; silver metal casing, with half seam; two plastic pieces of hardware; one a screw and socket, the other a protrusion with a piece of rubber encased wire extending from; blue writing to front surface
  2 images  
Accession Number
994007033
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Circular structure implantable pacemaker; silver metal casing, with half seam;
two plastic pieces of hardware; one a screw and socket, the other a protrusion
with a piece of rubber encased wire extending from; blue writing to front
surface
Number Of Parts
1
Maker
Medtronic
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1970
circa 1970
Date Remarks
Dr. Chiong's estimate
Material
metal: silver
rubber: transparent
Inscriptions
Front reads:"MEDTRONIC tm // CHARDACK tm // PULSE GENERATOR // USA // 5943 //
1L02281"
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 8.0 cm. x Depth: 2.5 cm. x Diam. : 6.5 cm. x Weight: 165.0 g.
Condition Remarks
Overall condition good; surface tarnish
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #1
Exhibit History
Dec. 1994
Pacemaker Exhibit - KGH Cardiology
Images
Less detail

pulse generator

https://mhc.andornot.com/en/permalink/artifact106
Dates
1986
circa 1986
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007051
Description
Internal pacemaker; rounded rectangular shape; stainless steel; clear plastic attachment to top (insert for wires); maker name, mark and info engraved to front
  1 image  
Accession Number
994007051
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rounded rectangular shape; stainless steel; clear plastic attachment
to top (insert for wires); maker name, mark and info engraved to front
Number Of Parts
1
Maker
Medtronic
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1986
circa 1986
Date Remarks
Dr. Chiong's estimate
Material
metal: silver
plastic: clear
Inscriptions
Engraved to front: MODEL 7000 A // A-V PULSE GENERATOR // TG2208053H //
MEDTRONIC INC // MINNEAPOLIS, MN // USA
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 6.0 cm. x Width: 5.5 cm. x Depth: 1.0 cm.
Condition Remarks
Overall condition good; slightly grimy
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #3
Exhibit History
May 24 - Sept. 13, 2001: Agnes Etherington Art Centre Museopathy exhibit
Images
Less detail

Activitrax pulse generator

https://mhc.andornot.com/en/permalink/artifact113
Dates
1985
circa 1985
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007058
Description
Internal pacemaker; oblong shape; stainless steel; plastic attachment to top (insert for wires); maker mark, name and info engraved to front surface
  1 image  
Accession Number
994007058
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; oblong shape; stainless steel; plastic attachment to top
(insert for wires); maker mark, name and info engraved to front surface
Number Of Parts
1
Maker
Medtronic, Inc.
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1985
circa 1985
Date Remarks
Dr. Chiong's notes; original record had "Sept. 1985"
Material
metal: silver
plastic: clear
Inscriptions
Engraved to front: ACTIVITRAX 8402 // VVIC + ACTIVITY // PULSE GENERATOR //
IW10001 80R // MEDTRONIC INC // MINNEAPOLIS, MN // USA
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 6.0 cm. x Width: 4.6 cm. x Depth: 1.2 cm.
Condition Remarks
overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #4
Images
Less detail

15 records – page 1 of 2.