Skip header and navigation

Refine By

2 records – page 1 of 1.

Flexi-T 300 intrauterine device

https://mhc.andornot.com/en/permalink/artifact9865
Dates
2001
Collection
Dr. Robert Reid Collection
Category
Patient Care Artifacts
Classification
Patient Care
Accession Number
003008002 a-d
Description
A long thin single-piece cardboard box (a) containing a Flexi-T 300 intrauterine device (d) in plastic packaging with a paper backing (b); IUD is made from cyllindrical white polyethylene formed into the shape of a T with a small round knob at the top and bottom of the post and arms that curl downw…
  1 image  
Accession Number
003008002 a-d
Collection
Dr. Robert Reid Collection
Category
Patient Care Artifacts
Classification
Patient Care
MeSH Heading
Contraceptive Devices, Female
Description
A long thin single-piece cardboard box (a) containing a Flexi-T 300 intrauterine device (d) in plastic packaging with a paper backing (b); IUD is made from cyllindrical white polyethylene formed into the shape of a T with a small round knob at the top and bottom of the post and arms that curl downward toward its centre; post is wrapped in tightly-coiled copper wire which also holds the top of a long blue filament to the post; applicator is a clear plastic tube with black graduations on the side; the top of the IUD sticks out of one end of the tube and the filament extends from the other end; filament is held to the outside of the tube with a blue plastic attachment which can slide up and down; also included in the box is a folded paper instruction sheet (c).
Number Of Parts
4
Part Names
a - box - Size: Length 24.7 cm x Width 6.0 cm x Depth 1.1 cm
b - plastic packaging - Size: Length 23.8 cm x Width 4.9 cm x Depth 0.9 cm
c - paper instructions - Size: Length 29.5 cm x Width 21.0 cm
d - IUD - Size: Length 19.2 cm x Width 2.8 cm x Depth 0.6 cm
Provenance
Owned and used by Dr. Robert Reid at the Kingston General Hospital.
Maker
Prosan International B.V.
Site Made (City)
Arnhem
Site Made (Country)
Netherlands
Dates
2001
Date Remarks
Instructions indicate a five-year shelf life; expiration date on package is 2006
Material
paper: white, blue
plastic: white, clear, black, blue
metal: red
fabric: blue
Inscriptions
Graduations on the side of applicator are denoted at "4", "7" and "10"; front of box: "PROSAN // female health care // Flexi~T 300 Intrauterine contraceptive device // COPPER IUD // CE0344"; right side of box: "Flexi~T 300 [the number 2 in a circle with a diagonal line through it] ["STERILE
R" inside a rectangle] [hourglass shape with grains in the bottom] 2006_05 ["LOT" in a rectangle] 01E11"; back of box: "patented product // PROSAN // female health care // Flexi~T 300 Intrauterine contraceptive device // to be inserted by a physician only [triangle with an exclamation point inside it] // COPPER IUD // CE0344"; left side of box: "Flexi~T 300 manufactured by Prosan International B.V. // IJsselburcht 3 - 6825 BS Arnhem - the Netherlands"; top of box: "Flexi~T 300"; on flap: Art.nr. 123070 Rev. 01"; bottom of box: "Flexi~T 300"; back of plastic packaging: "To be opened by // physician only // [exclamation mark inside a triangle] // ["LOT" in a rectangle] // 01E1 // [image of an hourglass with all grains in the bottom] // 2006-05 // Flexi-T 300 // ["STERILE
R" inside a rectangle] // CE0344 // Patented Product // Prosan International // IJaawlburcht 3 // 6825 BS Arnhem // Tel: +31 26 365 33 63 // Fax: +31 26 365 33 69 // The Netherlands // REF: 123074 Rev.02 // [the number 2 in a circle with a diagonal line through it] // PEEL HERE // [arrow pointing downward]"; instruction sheet front: "Flexi~T 300/200 // intrauterine contraceptive device // PROSAN // female health care // [...] // INSTRUCTIONS FOR THE PHYSICIAN // [images depicting how to insert the IUD] // DESCRIPTION // The Flexi-T is an intrauterine device made of polyethylene mixed with barium sulfate which makes it visible to X-ray. [...] // The simple one-hand "push-in" technique requires neither sterile gloves nor a plunger. [...] // The design of the Flexi-T is based on data obtained through extensive in vivo measurements of the transverse and longitudinal dimensions of the // uterine cavities in thousands of fertile women of all age and parity groups, resulting in an optimal compatibility. The shape of the Flexi-T avoids // irritation of the uterine mucosa and provides a "fundus seeking" and anti-expulsive mechanism (fig. 8). // INDICATION // Intrauterine contraceptive device for parous and nulliparous women. Postcoital interception. // MODE OF ACTION // [...] // TIME OF INSERTION // [...] // DURATION OF USE // [...]"; back of information sheet: "INSERTION PROCEDURE // [...] // REMOVAL // [...] // CONTRA-INDICATIONS // [...] // WARNINGS // [...] // SIDE EFFECTS // [...] // CHECK // [...] // INSTRUCTIONS FOR THE USER // [...] // PHARMACEUTICAL PRECAUTIONS // [...] // LEGAL CATEGORY CE 0344 // [...] // PACKAGING // Each blister contains one sterile IUD. // Expiry date is indicated on the package. When stored in a dry place // at room temperature the maximum shelf life is 5 years. // Cartons containing: 1 x 1 sterile Flexi-T // 10 x 1 sterile Flexi-T // art. nr. 125011 Rev. 04, Juli 2001"
Permanent Location
Storage Room 0010
0010-A4-4
Condition Remarks
Little wear to box; instruction sheet creased at one corner; IUD in good condition; packaging opened; thin paper peeled away from plastic.
Copy Type
Original
Reference Types
JPG
Reference Comments
CD #4
Research Facts
Inserted into the uterus to prevent conception; the polyethylene in the IUD is mixed with barium sulfate to make it visible on X-rays.
Exhibit History
History of Contraception exhibit, Fraser-Armstrong 5, Kingston General Hospital; March 2004 - Case #3
Images
Less detail
Collection
Dr. Michael A. Chiong Patent Medicine Collection
Category
Diagnostic & Treatment Artifacts
Pharmacy and Drug Artifacts
Home Health Care
Classification
Pharmacy, General
Pharmacy, Gastrointestinal
Treatment
Treatment, General
Home Health
Accession Number
996001261
Description
Cylindrical wooden container (sealed) containing Radio Pills; the container is sealed with a single sheet of printed paper which keeps the removable top sealed to the container; there are 25 pills in the container.
  1 image  
Accession Number
996001261
Collection
Dr. Michael A. Chiong Patent Medicine Collection
Category
Diagnostic & Treatment Artifacts
Pharmacy and Drug Artifacts
Home Health Care
Classification
Pharmacy, General
Pharmacy, Gastrointestinal
Treatment
Treatment, General
Home Health
MeSH Heading
Pharmaceutical Preparations
Pharmaceuticals
Pharmacy
Drug Packaging -- container -- bottle
Drugs
Cathartics
Constipation -- drug therapy
Drugs, Non-Prescription
MM= Drugs -- patent, proprietary, over-the-counter -- container
MM= Drug Packaging -- container -- vial
Description
Cylindrical wooden container (sealed) containing Radio Pills; the container is sealed with a single sheet of printed paper which keeps the removable top sealed to the container; there are 25 pills in the container.
Number Of Parts
1
Provenance
Purchased by Dr. M. Chiong for his patent medicine collection; purchased from Goodrich, USA, in Oct. 1993.
Maker
Radio-Medical Laboratories
Site Made (City)
Asbury Park
Site Made (State)
New Jersey
Site Made (Country)
United States of America
Material
wood: beige
paper: off-white
Inscriptions
Label reads, "Radio-Pills // TRADE MARK // The Latest // Scientific Laxative // The improved, safe, harmless little pill // Recommended in the treatment of con- // stipation, Headache, Colds, Biliousness, // Torpid Liver, Intestinal and Gastric In- // digestion, Dyspepsia, also Neuritis. // We guarantee the purity of every in- // gredient. They do not contain calomel, // narcotics or other harmful, injurious drugs. // Dose: One or two pills taken at // night. Children over 8 years, 1 pill // For Sale at all Druggists // PRICE 25 CENTS // RADIO-MEDICAL LABORATORIES // Asbury Park, N.J."
Permanent Location
Storage Room 0010
0010-A2-3 Row D
Dimension Notes
Length: 7.7 cm. x Diam. : 2.0 cm.
Condition Remarks
The wooden container is unopened and undamaged; the paper seal shows very minor wear and staining; there are no rips, tears or missing sections and all of the writing is legible.
Copy Type
Original
Research Facts
Used as a laxative
Exhibit History
On exhibit, Billings Estate, 15 Jan 2009 - 31 Dec. 2009
Images
Less detail