Pacesetter lithium pacemaker

https://mhc.andornot.com/en/permalink/artifact159
Dates
1978
1979
circa 1978-1979
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007104
Description
Internal pacemaker; rectangular in shape; stainless steel; translucent rubber attachment to top; with insert for wire to one end of attachment; maker's mark, name and information imprinted to front surface in blue.
  2 images  
Accession Number
994007104
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rectangular in shape; stainless steel; translucent rubber attachment to top; with insert for wire to one end of attachment; maker's mark, name and information imprinted to front surface in blue.
Number Of Parts
1
Maker
Pacesetter Systems Inc.
Site Made (City)
Sylmar
Site Made (State)
California
Site Made (Country)
United States of America
Dates
1978
1979
circa 1978-1979
Date Remarks
Dr. Chiong's notes
Material
metal: silver
rubber: clear
Inscriptions
Imprinted to front: PACESETTER // SYSTEMS, INC. // SYLMAR, CA. USA // MDL - 201 // LITHIUM // PACEMAKER // VVI UNIPOLAR // S/N 2924
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 8.3 cm. x Width: 5.8 cm. x Depth: 1.3 cm.
Copy Type
Original
Images
Less detail

Ventricor fixed-rate pacer

https://mhc.andornot.com/en/permalink/artifact196
Dates
1970
1980
circa 1970-1980
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007141
Description
Internal pacemaker; circular; inner mechanics potted in translucent yellow plastic casing; with stainless steel plate to front; maker name and model information engraved to plate; attachment to top; insert for wire embedded to bottom side.
Accession Number
994007141
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; circular; inner mechanics potted in translucent yellow plastic casing; with stainless steel plate to front; maker name and model information engraved to plate; attachment to top; insert for wire embedded to bottom side.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1970
1980
circa 1970-1980
Material
plastic: yellow
metal: silver
Inscriptions
Engraved to plate: VENTR. OUTPUT // VENTRICOR // FIXED RATE PACER // 111C-6861 // RATE - 70 // cordis // MIAMI, FLORIDA
Permanent Location
Storage Room 0010
0010-E6-1
Dimension Notes
Length: 8.7 cm. x Width: 5.7 cm. x Depth: 2.5 cm. x Diam. : 5.7 cm.
Copy Type
Original
Exhibit History
"Pacemakers: Technology Development," HDH, 14 Feb. 2007
Less detail
Dates
1970
1979
circa 1970-1979
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007153
Description
Internal pacemaker; rectangular shape; stainless steel; translucent yellow plastic attachment to top; with insert to one end for wire; maker name and model information engraved to front surface.
  1 image  
Accession Number
994007153
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rectangular shape; stainless steel; translucent yellow plastic attachment to top; with insert to one end for wire; maker name and model information engraved to front surface.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Medcor
Site Made (City)
Hollywood
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1970
1979
circa 1970-1979
Date Remarks
estimate
Material
metal: silver
plastic: yellow
Inscriptions
Engraved to front: "ESB / Medcor // DEMAND PACER // (R-INHIBITED) // ICHD TYPE MODEL 3-70C // SN G3769B // HOLLYWOOD, FL, USA"
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 7.5 cm. x Width: 5.0 cm. x Depth: 1.3 cm.
Copy Type
Original
Exhibit History
"Pacemakers: Technology Development," HDH, 14 Feb. 2007
Images
Less detail

C-MOS I pacemaker

https://mhc.andornot.com/en/permalink/artifact214
Dates
1970
1979
circa 1970-1979
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007159
Description
Internal pacemaker; rectangular in shape; with inlet to top as insert for wire; inner mechanics potted in translucent yellow plastic casing; with stainless steel plate to front; maker name and model information engraved to plate.
  2 images  
Accession Number
994007159
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rectangular in shape; with inlet to top as insert for wire; inner mechanics potted in translucent yellow plastic casing; with stainless steel plate to front; maker name and model information engraved to plate.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Intermedics Inc.
Site Made (City)
Freeport
Site Made (State)
Texas
Site Made (Country)
United States of America
Dates
1970
1979
circa 1970-1979
Date Remarks
estimate
Material
plastic: yellow
metal: silver
Inscriptions
Engraved to front plate: C - MOS I // Intermedics, Inc. // FREEPORT, TEXAS //
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 5.5 cm. x Width: 5.2 cm. x Depth: 2.0 cm.
Condition Remarks
Stainless steel plate corroding / rusting at edges where in contact with plastic casing
Copy Type
Original
Exhibit History
Loaned to Agnes Etherington Art Centre for Museopathy exhibit May 24–Sept. 13, 2001
Images
Less detail

Medtronic pulse generator

https://mhc.andornot.com/en/permalink/artifact215
Dates
1970
1989
circa 1970-1989
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007160
Description
Internal pacemaker; circular shape; stainless steel; rubber attachment to top; insert for wire; maker name and model information engraved to front surface.
Accession Number
994007160
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; circular shape; stainless steel; rubber attachment to top; insert for wire; maker name and model information engraved to front surface.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Medtronic
Site Made (City)
Minneapolis
Site Made (State)
Mn
Site Made (Country)
United States of America
Dates
1970
1989
circa 1970-1989
Material
rubber: clear
metal: silver
Inscriptions
Engraved to front: 5995 // RATE PROGRAMMABLE // VENTRICULAR INHIBITED // PULSE GENERATOR // VVI // MK001339 4R // MEDTRONIC INC // MINNEAPOLIS, MN // USA
Permanent Location
Storage Room 0010
0010-E6-1
Dimension Notes
Length: 6.0 cm. x Width: 5.5 cm. x Depth: 1.8 cm. x Diam. : 5.5 cm.
Copy Type
Original
Less detail

Medtronic pulse generator

https://mhc.andornot.com/en/permalink/artifact216
Dates
1970
1989
circa 1970-1989
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007161
Description
Internal pacemaker; circular shape; stainless steel; rubber attachment to top; insert for wire; maker name and model information engraved to front surface.
  2 images  
Accession Number
994007161
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; circular shape; stainless steel; rubber attachment to top; insert for wire; maker name and model information engraved to front surface.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Medtronic - Industria Brasileira
Site Made (Country)
Brazil
Dates
1970
1989
circa 1970-1989
Date Remarks
estimate
Material
rubber: clear
metal: silver
Inscriptions
Engraved to front: 5995 B// GERADOR DE PULSO // DE // FREQUENCIA PROGRAMAVEL // VVI // MK5001181S // C.C.C. (MF) 63105.183/0001-20 // INDUSTRIA BRASILEIRA
Permanent Location
Storage Room 0010
0010-E6-1
Dimension Notes
Length: 6.0 cm. x Width: 5.5 cm. x Depth: 1.8 cm. x Diam. : 5.5 cm.
Copy Type
Original
Images
Less detail

Medtronic pulse generator

https://mhc.andornot.com/en/permalink/artifact217
Dates
1970
1989
circa 1970-1989
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007162
Description
Internal pacemaker; circular shape; stainless steel; rubber attachment to top; insert for wire; maker name and model information engraved to front surface.
  2 images  
Accession Number
994007162
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; circular shape; stainless steel; rubber attachment to top; insert for wire; maker name and model information engraved to front surface.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Medtronic
Site Made (Country)
Brazil
Dates
1970
1989
circa 1970-1989
Date Remarks
estimate
Material
rubber: clear
metal: silver
Inscriptions
Engraved to front: 5995 B// GERADOR DE PULSO // DE // FREQUENCIA PROGRAMAVEL // VVI // MK5000240S // C.C.C. (MF) 63105.183/0001-20 // INDUSTRIA BRASILEIRA
Permanent Location
Storage Room 0010
0010-E6-1
Dimension Notes
Length: 6.0 cm. x Width: 5.5 cm. x Depth: 1.8 cm. x Diam. : 5.5 cm.
Copy Type
Original
Exhibit History
"Pacemakers: Technology Development," HDH, 14 Feb. 2007
Images
Less detail

Medtronic pulse generator

https://mhc.andornot.com/en/permalink/artifact218
Dates
1970
1989
circa 1970-1989
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007163
Description
Internal pacemaker; circular shape; stainless steel; rubber attachment to top; insert for wire; maker name and model information engraved to front surface.
Accession Number
994007163
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; circular shape; stainless steel; rubber attachment to top; insert for wire; maker name and model information engraved to front surface.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Medtronic
Site Made (Country)
Brazil
Dates
1970
1989
circa 1970-1989
Date Remarks
estimate
Material
rubber: clear
metal: silver
Inscriptions
Engraved to front: 5995 B// GERADOR DE PULSO // DE // FREQUENCIA PROGRAMAVEL // VVI // MK5000670S // C.C.C. (MF) 63105.183/0001-20 // INDUSTRIA BRASILEIRA
Permanent Location
Storage Room 0010
0010-E6-1
Dimension Notes
Length: 6.0 cm. x Width: 5.5 cm. x Depth: 1.8 cm. x Diam. : 5.5 cm.
Copy Type
Original
Less detail

Stanicor cardiac pacer

https://mhc.andornot.com/en/permalink/artifact222
Dates
1970
1974
circa 1970-1974
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007167
Description
Internal pacemaker; circular shape; inner mechanics potted in translucent yellow plastic casing; with insert to top for wires; stainless steel plate to front surface; maker name and model info engraved to plate.
  3 images  
Accession Number
994007167
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; circular shape; inner mechanics potted in translucent yellow plastic casing; with insert to top for wires; stainless steel plate to front surface; maker name and model info engraved to plate.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1970
1974
circa 1970-1974
Date Remarks
Dr. Chiong's notes; original record had "early 70s"
Material
plastic: yellow
metal: silver
Inscriptions
Engraved to plate: "Stanicor (R) // R-Wave Inhibited // Cardiac Pacer // er // Rate 70 // 143R7-52304 // cordis"
Permanent Location
Storage Room 0010
0010-E6-1
Dimension Notes
Length: 6.8 cm. x Width: 5.8 cm. x Depth: 2.3 cm.
Copy Type
Original
Images
Less detail

Stanicor cardiac pacer

https://mhc.andornot.com/en/permalink/artifact223
Dates
1970
1974
circa 1970-1974
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007168
Description
Internal pacemaker; circular shape; inner mechanics potted in translucent yellow plastic casing; with insert to top for wires; stainless steel plate to front surface; maker name and model info engraved to plate.
  3 images  
Accession Number
994007168
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; circular shape; inner mechanics potted in translucent yellow plastic casing; with insert to top for wires; stainless steel plate to front surface; maker name and model info engraved to plate.
Number Of Parts
1
Provenance
Used at Kingston General Hospital.
Maker
Cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1970
1974
circa 1970-1974
Date Remarks
Dr. Chiong's notes; original record had "early 70s"
Material
plastic: yellow
metal: silver
Inscriptions
Engraved to plate: "Stanicor (R) // R-Wave Inhibited // Cardiac Pacer // er // Rate 70 // 143R7-54331 // cordis"
Permanent Location
Storage Room 0010
0010-E6-1
Dimension Notes
Length: 6.8 cm. x Width: 5.8 cm. x Depth: 2.3 cm.
Copy Type
Original
Images
Less detail

1115 records – page 1 of 112.