Flexi-T 300 intrauterine device

https://mhc.andornot.com/en/permalink/artifact9865
Dates
2001
Collection
Dr. Robert Reid Collection
Category
Patient Care Artifacts
Classification
Patient Care
Accession Number
003008002 a-d
Description
A long thin single-piece cardboard box (a) containing a Flexi-T 300 intrauterine device (d) in plastic packaging with a paper backing (b); IUD is made from cyllindrical white polyethylene formed into the shape of a T with a small round knob at the top and bottom of the post and arms that curl downw…
  1 image  
Accession Number
003008002 a-d
Collection
Dr. Robert Reid Collection
Category
Patient Care Artifacts
Classification
Patient Care
MeSH Heading
Contraceptive Devices, Female
Description
A long thin single-piece cardboard box (a) containing a Flexi-T 300 intrauterine device (d) in plastic packaging with a paper backing (b); IUD is made from cyllindrical white polyethylene formed into the shape of a T with a small round knob at the top and bottom of the post and arms that curl downward toward its centre; post is wrapped in tightly-coiled copper wire which also holds the top of a long blue filament to the post; applicator is a clear plastic tube with black graduations on the side; the top of the IUD sticks out of one end of the tube and the filament extends from the other end; filament is held to the outside of the tube with a blue plastic attachment which can slide up and down; also included in the box is a folded paper instruction sheet (c).
Number Of Parts
4
Part Names
a - box - Size: Length 24.7 cm x Width 6.0 cm x Depth 1.1 cm
b - plastic packaging - Size: Length 23.8 cm x Width 4.9 cm x Depth 0.9 cm
c - paper instructions - Size: Length 29.5 cm x Width 21.0 cm
d - IUD - Size: Length 19.2 cm x Width 2.8 cm x Depth 0.6 cm
Provenance
Owned and used by Dr. Robert Reid at the Kingston General Hospital.
Maker
Prosan International B.V.
Site Made (City)
Arnhem
Site Made (Country)
Netherlands
Dates
2001
Date Remarks
Instructions indicate a five-year shelf life; expiration date on package is 2006
Material
paper: white, blue
plastic: white, clear, black, blue
metal: red
fabric: blue
Inscriptions
Graduations on the side of applicator are denoted at "4", "7" and "10"; front of box: "PROSAN // female health care // Flexi~T 300 Intrauterine contraceptive device // COPPER IUD // CE0344"; right side of box: "Flexi~T 300 [the number 2 in a circle with a diagonal line through it] ["STERILE
R" inside a rectangle] [hourglass shape with grains in the bottom] 2006_05 ["LOT" in a rectangle] 01E11"; back of box: "patented product // PROSAN // female health care // Flexi~T 300 Intrauterine contraceptive device // to be inserted by a physician only [triangle with an exclamation point inside it] // COPPER IUD // CE0344"; left side of box: "Flexi~T 300 manufactured by Prosan International B.V. // IJsselburcht 3 - 6825 BS Arnhem - the Netherlands"; top of box: "Flexi~T 300"; on flap: Art.nr. 123070 Rev. 01"; bottom of box: "Flexi~T 300"; back of plastic packaging: "To be opened by // physician only // [exclamation mark inside a triangle] // ["LOT" in a rectangle] // 01E1 // [image of an hourglass with all grains in the bottom] // 2006-05 // Flexi-T 300 // ["STERILE
R" inside a rectangle] // CE0344 // Patented Product // Prosan International // IJaawlburcht 3 // 6825 BS Arnhem // Tel: +31 26 365 33 63 // Fax: +31 26 365 33 69 // The Netherlands // REF: 123074 Rev.02 // [the number 2 in a circle with a diagonal line through it] // PEEL HERE // [arrow pointing downward]"; instruction sheet front: "Flexi~T 300/200 // intrauterine contraceptive device // PROSAN // female health care // [...] // INSTRUCTIONS FOR THE PHYSICIAN // [images depicting how to insert the IUD] // DESCRIPTION // The Flexi-T is an intrauterine device made of polyethylene mixed with barium sulfate which makes it visible to X-ray. [...] // The simple one-hand "push-in" technique requires neither sterile gloves nor a plunger. [...] // The design of the Flexi-T is based on data obtained through extensive in vivo measurements of the transverse and longitudinal dimensions of the // uterine cavities in thousands of fertile women of all age and parity groups, resulting in an optimal compatibility. The shape of the Flexi-T avoids // irritation of the uterine mucosa and provides a "fundus seeking" and anti-expulsive mechanism (fig. 8). // INDICATION // Intrauterine contraceptive device for parous and nulliparous women. Postcoital interception. // MODE OF ACTION // [...] // TIME OF INSERTION // [...] // DURATION OF USE // [...]"; back of information sheet: "INSERTION PROCEDURE // [...] // REMOVAL // [...] // CONTRA-INDICATIONS // [...] // WARNINGS // [...] // SIDE EFFECTS // [...] // CHECK // [...] // INSTRUCTIONS FOR THE USER // [...] // PHARMACEUTICAL PRECAUTIONS // [...] // LEGAL CATEGORY CE 0344 // [...] // PACKAGING // Each blister contains one sterile IUD. // Expiry date is indicated on the package. When stored in a dry place // at room temperature the maximum shelf life is 5 years. // Cartons containing: 1 x 1 sterile Flexi-T // 10 x 1 sterile Flexi-T // art. nr. 125011 Rev. 04, Juli 2001"
Permanent Location
Storage Room 0010
0010-A4-4
Condition Remarks
Little wear to box; instruction sheet creased at one corner; IUD in good condition; packaging opened; thin paper peeled away from plastic.
Copy Type
Original
Reference Types
JPG
Reference Comments
CD #4
Research Facts
Inserted into the uterus to prevent conception; the polyethylene in the IUD is mixed with barium sulfate to make it visible on X-rays.
Exhibit History
History of Contraception exhibit, Fraser-Armstrong 5, Kingston General Hospital; March 2004 - Case #3
Images
Less detail

Harvey double head stethoscope

https://mhc.andornot.com/en/permalink/artifact15278
Dates
1996
2005
circa 1996-2005
Collection
Dr. John Anderson Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnosis, General
Diagnosis
Accession Number
009046024
Description
Rectangular cardboard box containing "The Harvey Double Head Stethoscope"; the box is in two parts (a, b), and the top slides over the bottom; the lid contains a photograph of a stethoscope on a background of a white button down shirt with a chest pocket; the title is printed in black and white abo…
  5 images  
Accession Number
009046024
Collection
Dr. John Anderson Collection
Category
Diagnostic & Treatment Artifacts
Classification
Diagnosis, General
Diagnosis
MeSH Heading
Auscultation
Auscultation -- instrumentation
Stethoscopes
Heart Sounds
Diagnosis
Diagnosis -- instrumentation
Description
Rectangular cardboard box containing "The Harvey Double Head Stethoscope"; the box is in two parts (a, b), and the top slides over the bottom; the lid contains a photograph of a stethoscope on a background of a white button down shirt with a chest pocket; the title is printed in black and white above the photograph on a blue background with a tan stripe, and around the photograph there are words printed in black detailing some of the features of the stethoscope; on the front side of the lid there is a white sticker with the date and manufacturing information on it, as well as a barcode; the booklet (u) has the same photograph and graphics style as the box lid; the inside of the booklet contains nine pages and a flap, as well as information on the inside covers; the booklet contains black and white illustrations, and gives information about the different parts of the stethoscope, how to adjust the headset, preparing for the exam, sites of auscultation, heart sounds and murmurs, the flat diaphragm, the corrugated diaphragm, the bell, helpful hints, warranty, ordering information, and care and maintenance; the back of the booklet contains a sticker with the European information; the stethoscope (parts c-i) has metal arms and black rubber tubing; the ear pieces become larger at the ends and the end of the stethoscope has two heads, a bell and a diaphragm; there is a metal piece with black rubber over it that connects the two metal arms to one another; in the box with the stethoscope are a cardboard insert (k) and a small plastic bag filled with three sets of ear pieces (two white and one grey) and a corrugated diaphragm;(m-t); a plastic bag (j) and a green piece of paper (l) with employee information on it.
Number Of Parts
21
Part Names
a - box: Length 31.3 cm X Width 13.6 cm X Height 5.8 cm
b - lid: Length 32.0 cm X Width 14.2 cm X Height 5.9 cm
c - stethoscope: Length 63.8 cm X Width 12.0 cm X Height 2.7 cm
d-e - ear pieces: Length 2.0 cm X Diameter 1.1 cm
f - bell: Height 1.3 cm X Diameter 2.8 cm
g - chestpiece: Height 1.0 cm X Diameter 4.4 cm
h - ring: Height 0.5 cm X Diameter 4.7 cm
i - diaphragm: Diameter 4.4 cm
j - plastic: Length 24.0 cm X Width 19.0 cm
k - cardboard: Length 30.8 cm X Width 35.2 cm
l - paper: Length 7.6 cm X Width 2.5 cm
m - plastic: Length 11.0 cm X Width 7.6 cm
n-o - ear pieces: Length 2.0 cm X Diameter 1.1 cm
p-q - ear pieces: Length 1.5 cm X Diameter 1.3 cm
r-s - ear pieces: Length 2.0 cm X Diameter 1.4 cm
t - diaphragm: Height 0.3 cm X Diameter 4.4 cm
u: booklet: Length 22.9 cm X Width 10.2 cm
Provenance
Owned by Effie and Elizabeth Curry.
Maker
Tycos: A Welch Allyn Company
Site Made (City)
Arden
Site Made (State)
North Carolina
Site Made (Country)
U.S.A.
Dates
1996
2005
circa 1996-2005
Date Remarks
Based on date printed on sticker and date donated to the museum
Material
paper: cream, green, white
ink: blue, brown, white, black, grey, green
metal: grey
rubber: black, grey, white
plastic: clear, black
Inscriptions
Embossed on chestpiece (g): "Tycos // ASHEVILLE, N.C., USA PAT. NO. 3109508"; printed on paper (l): "I Take Pride in Our Quality // Employee #9117 // TYCOS INSTRUMENTS, INC."; printed on top of lid (b): "The HARVEY // DOUBLE HEAD // Stethoscope // New Soft Eartips // Rotatablen Binaurals // Dual Channel Tubing // Brass Chestpiece // Construction // Tycos® A Welch Allyn // Company"; printed on sticker on front of lid: "Mfg: 11/20/96 // Tycos® // A Welch Allyn // Company // CE // 5079-28 // Harvey Stethoscope // Double Head // +H8575079280 // Tycos Instruments, Inc · 95 Old Shoals Road · Arden, NC 28704 USA"; printed on front of booklet (u): "The Original // HARVEY // Stethoscopes // A Superior "Time Tested" // Stethoscope for the // Auscultation of // the Heart // DOUBLE-HEAD — 5079-28 // Tycos® A Welch Allyn // Company"; printed on back of booklet (including sticker): "CE European Regulatory Manager // Medical Division, Welch Allyn Ltd. // Navan, Co. Meath, Republic of Ireland // Tycos® A Welch Allyn // Company // Tycos Instruments, Inc. // 95 Old Shoals Road // Arden, NC 28704 // Telephone: (704) 684-4895 // Tycos—a tradition of excellence // 95P319 // Printed in U.S.A.".
Permanent Location
Storage Room 0010
0010-F4-6
Unit Of Measure
centimeters
Condition Remarks
Rubber tubing on one side of stethoscope, where the rubber meets the metal binaural tubes.
Copy Type
original
Reference Types
Websites, patent, book, interview
Reference Comments
Welch Allyn, Hillrom, "Original Harvey Stethoscopes": https://www.welchallyn.com/en/products/categories/discontinued-products/physical-exam/stethoscopes/original_harvey_stethoscopes.html
US Patent 3,109,508: http://www.freepatentsonline.com/3109508.pdf
"A Journey of Hope", by Oscar Mann, Hamilton Books, Dec. 14, 2005, 302 pages, pg. 190-191: https://books.google.ca/books?id=Wa5IFsCb1SwC&dq=original+harvey+stethoscope&source=gbs_navlinks_s
"WATKINS PROCTOR HARVEY, MD:A Conversation With the Editor", December 30, 1999, interview between William Clifford Roberts, MD and Watkins Proctor Harvey, MD: https://documents.pub/document/watkins-proctor-harvey-md-a-conversation-with-the-editor.html
Research Facts
The Harvey Double Head Stethoscope was part of a collection of stethoscopes by the Welch Allyn company called "Original Harvey Stethoscopes". They are no longer sold, and were replaced by the Harvey DLX stethoscopes.
US Patent No. 3,109,508 was granted on November 5th, 1963, to Ralph Cefaly, and was for an acoustic stethoscope with three heads: a bell, a diaphragm, and a corrugated diaphragm.
In the mid-1950s, Dr. Watkins Proctor Harvey invented this three-headed stethoscope, the Harvey Stethoscope, and it was produced by the Cefaly Research Corporation of Brentwood, Maryland. It was sometimes known as the Harvey Cefaly Stethoscope. The corrugated diaphragm helps detect faint heart activity and a larger range of frequencies. The bell is especially good for detecting low frequency sounds. Low frequency heart sounds called gallops can be signs of heart disease, and are important to be able to detect.
Images
Less detail