Skip header and navigation

Refine By

   MORE

71 records – page 1 of 8.

Activitrax pulse generator

https://mhc.andornot.com/en/permalink/artifact113
Dates
1985
circa 1985
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007058
Description
Internal pacemaker; oblong shape; stainless steel; plastic attachment to top (insert for wires); maker mark, name and info engraved to front surface
  1 image  
Accession Number
994007058
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; oblong shape; stainless steel; plastic attachment to top
(insert for wires); maker mark, name and info engraved to front surface
Number Of Parts
1
Maker
Medtronic, Inc.
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1985
circa 1985
Date Remarks
Dr. Chiong's notes; original record had "Sept. 1985"
Material
metal: silver
plastic: clear
Inscriptions
Engraved to front: ACTIVITRAX 8402 // VVIC + ACTIVITY // PULSE GENERATOR //
IW10001 80R // MEDTRONIC INC // MINNEAPOLIS, MN // USA
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 6.0 cm. x Width: 4.6 cm. x Depth: 1.2 cm.
Condition Remarks
overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #4
Images
Less detail
Dates
1930
circa 1930
Collection
University Health Network - Academy of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Otolaryngology
Accession Number
1982.21.3
Description
A power-operated audiometer encased in a walnut veneer case with a carrying handle, earphones, and headband.
  1 image  
Accession Number
1982.21.3
Collection
University Health Network - Academy of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Otolaryngology
MeSH Heading
Hearing Tests
Hearing Loss
Deafness
Audiometry -- instrumentation
Description
A power-operated audiometer encased in a walnut veneer case with a carrying handle, earphones, and headband.
Part Names
case - Size: Length 33.0 cm x Width 22.0 cm x Depth 22.0 cm
Provenance
Acquired from the Academy of Medicine.; source: Dr. L. Cherkas, M.O.H., Peel Regional Health Unit, Brampton, Ont
Maker
Audiometer Sales Corp., Division of Maico Co., Inc.
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1930
circa 1930
Material
wood: brown
metal: yellow
rubber: black
Inscriptions
"Model 53 C Serial No. 34047 // Volts 117 Cycles 60 // Watts 30"
Permanent Location
Storage Room 0007
0007-G1-1
Copy Type
Original
Reference Types
JPG
Reference Comments
CD #UHN
Research Facts
Hearing loss scale: –1- to +95; frequency scale: 1200-6000.
Images
Less detail
Dates
1937
circa 1937
Collection
Museum of Health Care at Kingston Collection
Category
Diagnostic & Treatment Artifacts
Classification
Otolaryngology
Accession Number
006029001
Description
Wooden box with two metal handles and inset front panel with painted decorative stripes; front panel has two toggle switches, four dials including a hearing loss dial and frequency dail each with display window, five jacks and a red light; pencil attached to handle by fabric; on back of device is a…
  5 images  
Accession Number
006029001
Collection
Museum of Health Care at Kingston Collection
Category
Diagnostic & Treatment Artifacts
Classification
Otolaryngology
MeSH Heading
Hearing Tests
Hearing Loss
Deafness
Audiometry -- instrumentation
Description
Wooden box with two metal handles and inset front panel with painted decorative stripes; front panel has two toggle switches, four dials including a hearing loss dial and frequency dail each with display window, five jacks and a red light; pencil attached to handle by fabric; on back of device is a metal label with manufacturer information held in place by four metal screws; inset on back are a fuse, power plug and a plug terminal.
Number Of Parts
1
Provenance
Found in Collection.
Maker
Medical Acoustic Instrument Company (MAICO)
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1937
circa 1937
Date Remarks
Date based on internet document
Material
wood: brown
metal: black, grey
paint: yellow
Inscriptions
Painted on front panel: "MAICO // MEDICAL ACOUSTIC // INSTRUMENT CO. // MINNEAPOLIS MINN. // SERIAL NO. 4793"; painted on metal manufacturer label: "MAICO // HEARING AIDS AUDIOMETERS'; stamped on metal manufacturer label: "D5 . 110V . 25C . A.C"
Permanent Location
Storage Room 0007
0007-G1-3
Dimension Notes
Length 45.7 cm x Width 25.9 cm x Depth 19.5 cm
Condition Remarks
Wood shows minor scuffing
Copy Type
Original
Reference Types
JPG
Reference Comments
CD #2
Images
Less detail

Chardack-Greatbatch pacemaker

https://mhc.andornot.com/en/permalink/artifact82
Dates
1960
circa 1960
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007027
Description
Implantable pacemaker; circular structure; silicon rubber casing; with three rubber-encased wires extending from; maker's name imprinted on rubber casing of front surface.
  2 images  
Accession Number
994007027
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Implantable pacemaker; circular structure; silicon rubber casing; with three rubber-encased wires extending from; maker's name imprinted on rubber casing of front surface.
Number Of Parts
1
Maker
Medtronic
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1960
circa 1960
Date Remarks
Dr. Chiong's estimate
Material
rubber: white
metal: silver
Inscriptions
Imprinted on rubber casing: CHARDACK - GREATBATCH // PACEMAKER // MFGD BY // MPLS.MINN.USA
Permanent Location
Storage Room 0010
0010-E6-2
Temporary Location
Deaccessioned 2013
Dimension Notes
Length: 8.3 cm. x Width: 7.0 cm. x Depth: 2.5 cm. x Diam. : 6.8 cm. x Weight: 170.0 g.
Copy Type
Original
Reference Types
Person
Reference Comments
Dr. Chiong
Research Facts
Five cells; adjustable rate and current
Exhibit History
Pacemaker Exhibit - KGH Cardiology Dec. 1994
Images
Less detail

Chardack-Greatbatch pacemaker

https://mhc.andornot.com/en/permalink/artifact83
Dates
1960
circa 1960
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007028
Description
Implantable pacemaker; rough circular form with two sets of leads and mechanics visible; encased in cream-coloured rubber; two wire input tubes extending from bottom; one marked '+' and the other '-'; maker's name and mark imprinted to front surface.
  3 images  
Accession Number
994007028
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Implantable pacemaker; rough circular form with two sets of leads and mechanics visible; encased in cream-coloured rubber; two wire input tubes extending from bottom; one marked '+' and the other '-'; maker's name and mark imprinted to front surface.
Number Of Parts
1
Provenance
Collection was assembled over many years by Dr. R.O. West in the Division of Cardiology and Cardiology Laboratories at Kingston General Hospital.
Maker
Medtronic
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1960
circa 1960
Date Remarks
Dr. Chiong's estimate
Material
rubber: cream
metal: silver
Inscriptions
To front surface: CHARDACK GREATBATCH // PACEMAKER // MEDTRONIC // USA
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 6.8 cm. x Width: 6.5 cm. x Depth: 2.4 cm.
Condition Remarks
Overall condition good; #2: small gouge on front.
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #7
Research Facts
Weight: 165.0 g.
Exhibit History
Pacemaker Exhibit, KGH Cardiology, Dec. 1994
Images
Less detail

Chardack-Greatbatch pacemaker

https://mhc.andornot.com/en/permalink/artifact84
Dates
1960
1969
circa 1960-1969
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007029
Description
Internal pacemaker; rough circular form; inner mechanics visible; encased in a yellow transparent rubber; two wire input tubes extending from bottom, one marked '+', the other '-'; closed protrusion to side; maker's name and mark imprinted to front surface in white
  2 images  
Accession Number
994007029
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rough circular form; inner mechanics visible; encased in
a yellow transparent rubber; two wire input tubes extending from bottom, one
marked '+', the other '-'; closed protrusion to side; maker's name and mark
imprinted to front surface in white
Number Of Parts
1
Maker
Medtronic
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1960
1969
circa 1960-1969
Date Remarks
Dr. Chiong's estimate
Material
rubber: transparent; yellow
metal: silver
Inscriptions
To front: CHARDACK GREATBATCH // PACEMAKER // MEDTRONIC // USA
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 8.0 cm. x Width: 7.0 cm. x Depth: 2.5 cm. x Weight: 179.0 g.
Condition Remarks
overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #1
Exhibit History
“On loan L-2016-4” to the College of Physicians and Surgeons of Ontario’s 150th Anniversary exhibit; 30 April-8 July, 2016 Pacemaker Exhibit - KGH Cardiology Dec. 1994
Images
Less detail

Chardack Greatbatch pacemaker

https://mhc.andornot.com/en/permalink/artifact245
Dates
1969
circa 1969
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007190
Description
Internal pacemaker; circular shape; inner mechanics potted in translucent rubberplastic casing; stainless steel nameplate to front; insert for wires to side; rubber-coated wire extending from insert; maker name and model information engraved to nameplate
  1 image  
Accession Number
994007190
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; circular shape; inner mechanics potted in translucent rubberplastic
casing; stainless steel nameplate to front; insert for wires to side;
rubber-coated wire extending from insert; maker name and model information engraved
to nameplate
Number Of Parts
1
Maker
Medtronic
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1969
circa 1969
Date Remarks
Dr. Chiong's notes
Material
rubber-plastic: clear
metal: silver
Inscriptions
Engraved to nameplate: CHARDACK // GREATBATCH // PACEMAKER MFD. BY // MEDTRONIC
INC. // MPLS., MINN. USA // MODEL 5858
Permanent Location
Storage Room 0010
0010-E6-1
Dimension Notes
Length: 5.2 cm. x Width: 2.4 cm. x Diam. : 5.2 cm.
Condition Remarks
#2: rubber; requires special treatment
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #4
Exhibit History
Loaned to Agnes Etherington Art Centre for Museopathy exhibit May 24–Sept. 13, 2001; "Pacemakers: Technology Development," HDH, 14 Feb. 2007
Images
Less detail

Chardack Greatbatch pacemaker

https://mhc.andornot.com/en/permalink/artifact249
Dates
1966
circa 1966
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007194
Description
Internal pacemaker; round shape; plastic casing with rubber coating; four inserts; rubber-coated wire extends from an insert; maker name and model information moulded to outer casing
  2 images  
Accession Number
994007194
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; round shape; plastic casing with rubber coating; four inserts;
rubber-coated wire extends from an insert; maker name and model information
moulded to outer casing
Number Of Parts
1
Maker
Medtronic
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1966
circa 1966
Date Remarks
Dr. Chiong's notes
Material
plastic: white
rubber: white
Inscriptions
Moulded to outer casing: "CHARDACK-GREATBATCH // PACEMAKER // MFCD. BY // MEDTRONIC //
MPLS MINN. USA"; other side has the numbers "6H0306"
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 7.0 cm. x Width: 7.0 cm. x Depth: 2.2 cm.
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #6
Exhibit History
"Pacemakers: Technology Development," HDH, 14 Feb. 2007
Images
Less detail

Chardack pulse generator

https://mhc.andornot.com/en/permalink/artifact88
Dates
1970
circa 1970
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007033
Description
Circular structure implantable pacemaker; silver metal casing, with half seam; two plastic pieces of hardware; one a screw and socket, the other a protrusion with a piece of rubber encased wire extending from; blue writing to front surface
  2 images  
Accession Number
994007033
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Circular structure implantable pacemaker; silver metal casing, with half seam;
two plastic pieces of hardware; one a screw and socket, the other a protrusion
with a piece of rubber encased wire extending from; blue writing to front
surface
Number Of Parts
1
Maker
Medtronic
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1970
circa 1970
Date Remarks
Dr. Chiong's estimate
Material
metal: silver
rubber: transparent
Inscriptions
Front reads:"MEDTRONIC tm // CHARDACK tm // PULSE GENERATOR // USA // 5943 //
1L02281"
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 8.0 cm. x Depth: 2.5 cm. x Diam. : 6.5 cm. x Weight: 165.0 g.
Condition Remarks
Overall condition good; surface tarnish
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #1
Exhibit History
Dec. 1994
Pacemaker Exhibit - KGH Cardiology
Images
Less detail

commemorative plaque

https://mhc.andornot.com/en/permalink/artifact13135
Dates
1966
circa 1966
Collection
Dr. Ralph and Mrs. Olga Crawford Canadian Dental Collection
Category
Ephemera
Classification
Ephemera
Accession Number
010020046
Description
Commemorative plaque given by the Alberta Dental Association; engraved brass plate mounted on wooden base by four small screws in corners; orange metal attachment and silver metal attachment on back to mount plaque on wall
  2 images  
Accession Number
010020046
Collection
Dr. Ralph and Mrs. Olga Crawford Canadian Dental Collection
Category
Ephemera
Classification
Ephemera
MeSH Heading
Anniversaries and Special Events -- ephemera
Dentists
MM= Commemorative and Association Items
Description
Commemorative plaque given by the Alberta Dental Association; engraved brass plate mounted on wooden base by four small screws in corners; orange metal attachment and silver metal attachment on back to mount plaque on wall
Number Of Parts
1
Provenance
Transfer from the Dental Canada Fund; previously housed in the Dentistry Canada Museum (Ottawa)
Site Made (City)
Calgary
Site Made (State)
Alberta
Site Made (Country)
Canada
Dates
1966
circa 1966
Date Remarks
Printed on artefact
Material
wood: brown
metal: yellow, orange, silver
Inscriptions
Engraved on front: "50 // C. MONTAGUE SNOW //as a token of // Honor and Congratulations // From // The Alberta Dental Association // on the occasion of // Fifty Years of practice // 1916-1966"
Permanent Location
Storage Room 0010
0010-B
Dimension Notes
Length 22.7 cm x Width 17.8 cm x Depth 2.2 cm
Condition Remarks
Some scratches on metal; metal is slightly loosened from wood; wood worn at edges
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
J. Diane Snow
CD #9
Research Facts
Dr Ralph and Mrs Olga Crawford donated their extensive Canadian dental collection to the DCF to create the museum in 1997; further donations were received while Dr Crawford was Curator Emeritus at the Dental Canada Museum until its closure in 2008; this item was donated by J. Diane Snow from Vancouver, British Columbia and was originally owned by her father Dr. Cecil Montague Snow; who was an itinerant dentist from 1929-1942 in rural Saskatchewan, after which he settled in Calgary, Alberta; he graduated from the Baltimore College of Dental Surgery, University of Maryland in 1916
Images
Less detail

71 records – page 1 of 8.