electroconvulsive therapy apparatus

https://mhc.andornot.com/en/permalink/artifact1018
Dates
1950
1982
circa 1950-1982
Collection
Kingston General Hospital Collection
Category
Diagnostic & Treatment Artifacts
Classification
Psychiatry
Accession Number
997028001 a-e
Description
Mark 4 E.C.T. apparatus which consists of (a) the apparatus housed in a square wooden box with a lid that is hinged at the back, has two clasps on the left and right sides near the front and an attached leather handle on the front; the base houses the motor of the apparatus and is covered with a pa…
  5 images  
Accession Number
997028001 a-e
Collection
Kingston General Hospital Collection
Category
Diagnostic & Treatment Artifacts
Classification
Psychiatry
MeSH Heading
Electric Stimulation Therapy -- instrumentation
Electroconvulsive Therapy
Psychiatry -- instrumentation
Description
Mark 4 E.C.T. apparatus which consists of (a) the apparatus housed in a square wooden box with a lid that is hinged at the back, has two clasps on the left and right sides near the front and an attached leather handle on the front; the base houses the motor of the apparatus and is covered with a panel that has an on/off switch, a mains light, a treatment light, an output plug, a treat button and waveform and ectonus dials; there is an electric cord and plug that comes out of the back of the machine; the bottom of the machine has four round rubber feet on each corner; a headpiece (b) that consists of a rectangular plastic handle with a wood-covered cylindrical bar coming down from each end of the handle and with circular wooden-backed cotton-padded electrodes at the end of the bars; there is an electric cord leading out from the left side of the handle and a circular push-in button on the right side; the electrical cord plugs into the output plug of (a); the adpiece fits into the top of the apparatus box; there is another headpiece (c) that has a cylindrical handle with a semicircular piece on the bottom, that has a wooden-backed cotton-padded electrode at each end; the top of the headpiece handle has a push-in button; there is an electric cord leading out from the side, near the top; the electrical cord plugs into the output plug of the apparatus; there are also printed instructions (d) that come with the machine; the instructions are on two pieces of paper that have been covered with plastic, folded in half and stapled along the folded edge to form a small booklet; some accessories that came with the machine include: (e) a cardboard box that contains 69 individual packages (not accessioned) of electrolyte solution, which was used to soak the padded electrodes on the headpieces; there is also a plastic bag that contains 29 replacement pads (not accessioned) and a plastic package that contains 6 metal headpiece electrode backs, 4 wooden padding backs and 5 small, 6-sided screw nuts (not accessioned).
Number Of Parts
5
Part Names
a - electroconvulsive apparatus (closed) - Length 23.2 cm. x Width 22.8 cm. x Depth 16.5 cm.
b - headpiece (including cord length) - Length 206.5 cm. x Width 3.8 cm. x Depth 18.2 cm.
c - headpiece (including cord length) - Length 181.7 cm. x Width 3.8 cm. x Depth 17.3 cm.
d - printed instructions (folded) - Length 14.2 cm. x Width 20.2 cm.
e - box of electrolyte - Length 16.8 cm. x Width 16.6 cm. x Depth 8.4 cm.
Provenance
Used on Connell 4 at the Kingston General Hospital.
Maker
Ectron Ltd.
Site Made (City)
Knap Close
Site Made (Country)
England
Dates
1950
1982
circa 1950-1982
Date Remarks
Inspected by Clinical Engineering in Dec. of 1982
Material
metal: silver
plastic: white; green; black; grey
paper: white; green
wood: brown
leather: black
fabric: white
electrolyte: pink
cardboard: light grey
rubber: black
Inscriptions
(a) The panel reads, "DUOPULSE // MK. 4. E.C.T. APPARATUS // MADE IN ENGLAND // ECTRON LTD. // KNAP CLOSE // LETCHWORTH HERTS // WARNING // THIS APPARATUS SHOULD ONLY BE USED BY // TRAINED PERSONNEL AS THE OUTPUT CAN // BE DANGEROUS IF IMPROPERLY USED // A.C. INPUT POWER 90 WATTS. MAX. // OFF // ON // MAINS // TREATMENT // OUTPUT // TREAT // WAVEFORM // ECTONUS"; a small plastic label at the bottom of the panel reads, "PSYCH 396"; manufacturing label on the inside of the lid reads, "ECTRON LTD // KNAP CLOSE, LETCHWORTH, HERTS, ENGLAND // SERIAL NO. 134 // VOLTS 110 AMPS 1.0 HZ 60 // RISK CLASS 2, (REF. CSA STANDARD C22.2, No. 125)"; safety instructions and standards are also listed; a paper label in the middle of the panel reads, "In Canada: // HYBRID ELECTRONICS // 50 WINGOLD AVE, // TORONTO ONTARIO // M-3 1p7 // Telephone ---"; a paper label on the bottom of the apparatus reads, "CLINICAL ENGINEERING DEPT. // ACCEPTED // DATE: 20 DEC. 82 // INSPECTED BY: P.W."; (b) raised lettering on the headpiece handle reads, "ECTRON // MADE IN ENGLAND" on both sides; (d) the instructions are listed under the heading, "Operating Instructions for // Ectron Ectonus Ectonustim & Duopulse // Mark 4 E.C.T. Apparatus"; (e) a paper label on the cardboard box reads, "ELECTROLYTE // 100 Packets for E.C.T. // Electrolyte Solution // Ectron Ltd. // Knap Close // Letchworth Herts. SG6 1AQ // England"; directions on the individual packets read, "Dissolve contents in 1/2 pint (285 ml.) water. // Saturate Headband pads in this solution"
Permanent Location
(a-c,e) Storage Room 0007
0007-M1-4
(d) Storage Room 2005
2005-2-5 Box 18
Condition Remarks
(a) Shows some wear, but is complete; small paper label on the panel is water-damaged and missing w wear, especially the cotton pads; both cords are flexible; (d) instructions are complete and fully legible; (e) the cardboard box is heavily worn and water-damaged; packages of electrolyte solution were leaking powder; #2: rubber cord may require special treatment in the future; pink powder should possibly be removed; instructions to be removed and placed in archives.
Copy Type
Original
Research Facts
Also known as a shock therapy unit.
Images
Less detail

TMP Nurses Call System: TIN-103 [instruction manual]

https://mhc.andornot.com/en/permalink/artifact15003
Dates
1959
Collection
Kingston General Hospital Collection
Category
Archival Items
Classification
Archival, Publications
Nursing
Accession Number
012030002
Description
Instruction manual without covers made from standard copy paper and manufacturers data sheets on the medical equipment, bound together by two strands of thread in metal bound holes; first section information is in mimeographed purple ink; the first seven pages describe the technical side of the TMP…
  1 image  
Accession Number
012030002
Collection
Kingston General Hospital Collection
Category
Archival Items
Classification
Archival, Publications
Nursing
MeSH Heading
Nurses
Nursing
Nursing Care -- manuals
Description
Instruction manual without covers made from standard copy paper and manufacturers data sheets on the medical equipment, bound together by two strands of thread in metal bound holes; first section information is in mimeographed purple ink; the first seven pages describe the technical side of the TMP nurse call system, including how it operates when used, how to call a patient, how patients may make emergency calls, a table of the components of standard TMP systems, etc; next five pages provide images and descriptions of types of nursing equipment and stations associated with the product, printed in black; final six pages are technical drawings of the equipment printed in black; includes handwritten scribbles of long division on cover.
Number Of Parts
1
Provenance
Owned by the Kingston General Hospital before arriving to the Museum of Health Care.
Maker
The Standard Electric Time Company
Site Made (City)
Point-Claire
Site Made (State)
Quebec
Site Made (Country)
Canada
Dates
1959
Date Remarks
Publication date
Material
paper: cream, white
ink: black, purple
fabric: cream
Inscriptions
On the front: "TMP NURSES CALL SYSTEM // TIN-103"; inside: "TMP TYPE NURSE CALL SYSTEM // TECHNICAL INSTRUCTION MANUAL"; "TABLE 1 // TMP NURSES CALL SYSTEM"; "Following is a list of main components of a standard TMP type system together // with mounting and other details. See Data Sheets as shown below."; further in booklet are the manufacturers information: "NURSES' STATION EQUIPMENT // FOR ROYALMATIC NURSE SAVER EQUIPMENT // DATA FILE SHEET // FILE 30-110 / CAN. JAN. 1959"; chapters include: "NURSE SAVER CALL STATIONS"; "OPERATING AND OBSTETRIC ROOM STATIONS"; "DUTY STATIONS"; "CORRIDOR LIGHTS"
Permanent Location
Storage Room 2005
2005-5-6 Binder B pg 9 a
Length
28 cm
Width
22 cm
Depth
0.3 cm
Unit Of Measure
centimeters
Condition Remarks
Inside the manual is in excellent condition, cover is heavily stained and creased near the spine; handwritten notations in pencil and pen on the front cover
Copy Type
original
Images