Skip header and navigation

Refine By

   MORE

349 records – page 1 of 35.

Activitrax 8400 pulse generator

https://mhc.andornot.com/en/permalink/artifact207
Dates
1980
1999
circa 1980-1999
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007152
Description
Internal pacemaker; oblong shape; stainless steel; clear plastic attachment to top; with insert for wire; maker name and model information engraved to front surface
  1 image  
Accession Number
994007152
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; oblong shape; stainless steel; clear plastic
attachment to top; with insert for wire; maker name and model information
engraved to front surface
Number Of Parts
1
Maker
Medtronic
Site Made (City)
Minneapolis
Site Made (State)
Mn.
Site Made (Country)
United States of America
Dates
1980
1999
circa 1980-1999
Date Remarks
estimate
Material
metal: silver
plastic: clear
Inscriptions
Engraved to front: ACTIVITRAX 8400 // VVIC + ACTIVITY // PULSE GENERATOR //
IJ2301 337H // MEDTRONIC INC. // MINNEAPOLIS, MN USA
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 6.0 cm. x Width: 4.3 cm. x Depth: 1.0 cm.
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #4
Images
Less detail

Activitrax II pulse generator

https://mhc.andornot.com/en/permalink/artifact104
Dates
1988
circa 1988
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007049
Description
Internal pacemaker; oblong; stainless steel; clear plastic attachment to top (insert for wires); maker name, mark and info engraved to front surface
  1 image  
Accession Number
994007049
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; oblong; stainless steel; clear plastic attachment to top
(insert for wires); maker name, mark and info engraved to front surface
Number Of Parts
1
Maker
Medtronic
Site Made (City)
Mississauga
Site Made (State)
Ontario
Site Made (Country)
Canada
Dates
1988
circa 1988
Date Remarks
Dr. Chiong's estimate
Material
metal: silver
plastic: clear
Inscriptions
Engraved to front: ACTIVITRAX II 8412 // VVIC + ACTIVITY // PULSE
GENERATOR // QE 4100623M // MEDTRONIC CANADA // MISSISSAUGA, ONT // CANADA
Permanent Location
Storage Room 0010
0010-E6-3
Condition Remarks
Overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #4
Images
Less detail

Activitrax pulse generator

https://mhc.andornot.com/en/permalink/artifact100
Dates
1988
circa 1988
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007045
Description
Internal pacemaker; oval form; stainless steel; with transparent plastic attachment to top; input socket for wires; maker and unit information engraved to front surface. Weight: 44.0 g.
  1 image  
Accession Number
994007045
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; oval form; stainless steel; with transparent plastic attachment to top; input socket for wires; maker and unit information engraved to front surface. Weight: 44.0 g.
Number Of Parts
1
Maker
Medtronic
Site Made (City)
Mississauga
Site Made (State)
Ontario
Site Made (Country)
Canada
Dates
1988
circa 1988
Date Remarks
Dr. Chiong's estimate; original record had "Jan. 1988"
Material
metal: silver
plastic: clear
Inscriptions
Engraved to front surface: ACTIVITRAX II 8412 // VVIC + ACTIVITY // PULSE
GENERATOR // QE4100707M // MEDTRONIC CANADA // MISSISSAUGA, ONT // CANADA
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length 6.0 cm. x Width 4.3 cm. x Depth 1.2 cm.
Condition Remarks
Overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #1
Exhibit History
Pacemaker Exhibit - KGH Cardiology Dec. 1994
Images
Less detail

Activitrax pulse generator

https://mhc.andornot.com/en/permalink/artifact113
Dates
1985
circa 1985
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007058
Description
Internal pacemaker; oblong shape; stainless steel; plastic attachment to top (insert for wires); maker mark, name and info engraved to front surface
  1 image  
Accession Number
994007058
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; oblong shape; stainless steel; plastic attachment to top
(insert for wires); maker mark, name and info engraved to front surface
Number Of Parts
1
Maker
Medtronic, Inc.
Site Made (City)
Minneapolis
Site Made (State)
Minnesota
Site Made (Country)
United States of America
Dates
1985
circa 1985
Date Remarks
Dr. Chiong's notes; original record had "Sept. 1985"
Material
metal: silver
plastic: clear
Inscriptions
Engraved to front: ACTIVITRAX 8402 // VVIC + ACTIVITY // PULSE GENERATOR //
IW10001 80R // MEDTRONIC INC // MINNEAPOLIS, MN // USA
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 6.0 cm. x Width: 4.6 cm. x Depth: 1.2 cm.
Condition Remarks
overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #4
Images
Less detail

Activitrax pulse generator

https://mhc.andornot.com/en/permalink/artifact114
Dates
1985
circa 1985
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007059
Description
Internal pacemaker; oblong shape; stainless steel; plastic attachment to top (insert for wires); rubber-coated wire extends from attachment; maker mark, name and info engraved to front surface Note: in wire: length 21.5
  1 image  
Accession Number
994007059
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; oblong shape; stainless steel; plastic attachment to top
(insert for wires); rubber-coated wire extends from attachment; maker mark,
name and info engraved to front surface
Note: in wire: length 21.5
Number Of Parts
1
Maker
Medtronic
Site Made (Country)
Holland
Dates
1985
circa 1985
Date Remarks
Dr. Chiong's notes
Material
metal: silver
plastic: clear
rubber: clear
Inscriptions
Engraved to front: ACTIVITRAX 8403 // VVIC + ACTIVITY // PULSE GENERATOR //
IY3202423K // MEDTRONIC BV // HOLLAND
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length 6.0 cm. x Width 4.6 cm. x Depth 1.2 cm.
Condition Remarks
overall condition good
Copy Type
Original
Reference Types
Personl
JPG
Reference Comments
Dr. Chiong; CD #4
Images
Less detail

all-electric model Hindle electrocardiograph

https://mhc.andornot.com/en/permalink/artifact7488
Collection
University Health Network - Academy of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
1978.31.2 a-c
Description
A rectangular mahogany case (c) has a two-piece lid that fits over the top of the machine and down its front; there is a plastic control panel at the back left corner that has knobs and gauges; at front left is a string galvanometer; below the galvanometer is a voltage gauge with a scale ranging fr…
  1 image  
Accession Number
1978.31.2 a-c
Collection
University Health Network - Academy of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Electrocardiography, instrumentation
Cardiology -- instrumentation
Description
A rectangular mahogany case (c) has a two-piece lid that fits over the top of the machine and down its front; there is a plastic control panel at the back left corner that has knobs and gauges; at front left is a string galvanometer; below the galvanometer is a voltage gauge with a scale ranging from 0 to 7; at front middle is a round, black motor, which is connected by a rubber belt to a film canister at front right; canister is contained in a metal compartmentwith a sliding door at the front (a); on top of the compartment is a voltage gauge with a scale from 0 to 7; on the side of the compartment, which receives the galvanometer ray, is a calibrated slit through which the ray passes to be recorded on the oscilligraph inside the compartment; behind the compartment that contains the film canister is a rectangular section for a long coil of wires one end of which is linked to the bottom of the panel; the section is formed by a metal slide plate (b).
Number Of Parts
3
Part Names
a - sliding door
b - sliding plate
c - case - Size: Length 30.5 cm x Width 33.7 cm x Depth 24.7 cm
Provenance
Acquired from the Academy of Medicine; source: Dr. A.J. Kerwin of Toronto.
Maker
Cambridge Instrument Co. Inc.
Site Made (City)
Ossining
Site Made (State)
New York
Site Made (Country)
United States of America
Material
plastic: black; yellow
wood: brown
glass: clear
metal: yellow; black
leather: brown
Inscriptions
On lower centre of panel is a logo, followed by: "CAMBRIDGE INSTRUMENT CO. Inc. // OSSINING, N.Y. NO: BM4210"; on front side of wooden case is a plastic plate that says, "ALL-ELECTRIC MODEL // "HINDLE" ELECTROCARDIOGRAPH // NO. 0-8718 // MADE FOR // H.K. DETWEILER, M.D. // BY THE // CAMBRIDGE INSTRUMENT CO. INC."
Permanent Location
Storage Room 0007
0007-I1-2
Condition Remarks
Machine base mouldy and dirty; long coil of wire unusable if not repaired; covering bag is dirty; a splinter of wood found inside the case, fallen off from top inner surface; #2: Leather case is in bad shape.
Copy Type
Original
Reference Types
JPG
Reference Comments
CD #UHN
Images
Less detail

All-electric model Hindle electrocardiograph

https://mhc.andornot.com/en/permalink/artifact5892
Dates
1935
1940
circa 1935-1940
Collection
University Health Network - Academy of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
1969.27.1 a-e
Description
Rectangular mahogany case with a two-piece lid that fits over top of machine and down its front; inside of case at back left and extending to just beyond back middle is a control panel with four dials, two levers, and a gauge that measures milliamperes; at top front is a circular volt gauge and to …
  1 image  
Accession Number
1969.27.1 a-e
Collection
University Health Network - Academy of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Electrocardiography, instrumentation
Cardiology -- instrumentation
Description
Rectangular mahogany case with a two-piece lid that fits over top of machine and down its front; inside of case at back left and extending to just beyond back middle is a control panel with four dials, two levers, and a gauge that measures milliamperes; at top front is a circular volt gauge and to the left of that is a circular plastic knob with an arrow on top; at extreme left of machine, toward the bottom and lying horizontally is another volt (DC) gauge and to the right of that is a circular plastic knob with an arrow on top; beneath the gauge on the right is a removable panel, and behind the panel are two canisters (c,d).
Number Of Parts
5
Part Names
a - main unit - Size: Length 64.1 cm x Width 23.8 cm x Depth 30.4 cm
b - panel to camera unit - Size: Length 22.5 cm x Width 13.3 cm
c - metal canister - Size: Length 9.5 cm x Diam. 8.9 cm
d - cardboard canister - Size: Length 8.9 cm x Diam. 9.3 cm
e - glass rectangle - Size: Length 6.0 cm x Width 2.5 cm
Provenance
Acquired from the Academy of Medicine; source: Dr. K.W.G. Brown; made for Dr. H.E. Rykert.
Maker
Cambridge Instrument Co., Inc.
Site Made (City)
Ossining
Site Made (State)
New York
Site Made (Country)
United States of America
Dates
1935
1940
circa 1935-1940
Material
wood: brown
metal: yellow; black; white
glass: clear; yellow
plastic: black
Inscriptions
Inscribed on a brass plate on inside lid: "ALL ELECTRICAL MODEL // "HINDLE" ELECTROCARDIOGRAPH // NO. 0–14813 // MADE FOR // H.E. RYKERT. M.D. // BY THE // CAMBRIDGE INSTRUMENT CO. INC."
Permanent Location
Storage Room 0007
0007-I1-1
Copy Type
Original
Reference Types
Photo
JPG
Reference Comments
CD #UHN
Images
Less detail

AO demand pacer

https://mhc.andornot.com/en/permalink/artifact64
Dates
1950
1970
circa 1950-1970
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007009 a-b
Description
Small grey metal demand pacer 2002 by American Optical
  3 images  
Accession Number
994007009 a-b
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Small grey metal demand pacer 2002 by American Optical
Number Of Parts
2
Part Names
a - pacemaker - Size: Length 20.5 cm. x Width 16.7 cm. x Depth 5.5 cm.
b - cord - Size: Length 310.0 cm. x Width 3.0 cm. x Diameter0.5 cm.
Provenance
Used on KGH patients
Maker
American Optical Corp.
Site Made (City)
Bedford
Site Made (State)
Massachusetts
Site Made (Country)
United States of America
Dates
1950
1970
circa 1950-1970
Material
plastic: black; grey
metal: light grey; black
Inscriptions
A0 DEMAND PACER / 2002 // SERIAL NO. 1086
AMERICAN OPTICAL // CORPORATION // MEDICAL DIVISION . BEDFORD, MASS. 01730
Permanent Location
Storage Room 0007
0007-J2-5
Condition Remarks
Lots of tape residue; shows wear and grime; #2: sticky masking tape; #3: rubber cord
Reference Types
JPG
Reference Comments
CD #6
Images
Less detail

asynchronous pulse generator

https://mhc.andornot.com/en/permalink/artifact257
Dates
1960
1969
circa 1960-1969
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007202
Description
Internal pacemaker; rectangular shape; with inlet/insert for wire; inner mechanics potted in semi-transparent epoxy-rubber casing; maker and model information inlaid to casing front and back
  3 images  
Accession Number
994007202
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rectangular shape; with inlet/insert for wire; inner mechanics
potted in semi-transparent epoxy-rubber casing; maker and model information inlaid
to casing front and back
Number Of Parts
1
Maker
General Electric
Site Made (Country)
United States of America
Dates
1960
1969
circa 1960-1969
Material
rubber: semi-transparent
Inscriptions
Front reads: GENERAL ELECTRIC // ASYNCHRONOUS // PULSE GENERATOR // A2073AB //
Made in USA; back reads: GENERAL ELECTRIC // (READ INSTRUCTIONS) //ONLY REMOVE //
THIS LABEL FOR // UNIPOLAR PACING
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 6.1 cm. x Width: 5.7 cm. x Depth: 2.3 cm.
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #6
Images
Less detail

Atricor synchronous pacer

https://mhc.andornot.com/en/permalink/artifact86
Dates
1960
1969
circa 1960-1969
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007031
Description
Circular form; transparent encased ; steel name plate to front surface; inner mechanics visible; wire input socket to top; weighs 140 gm.
  2 images  
Accession Number
994007031
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Circular form; transparent encased ; steel name plate to front surface; inner mechanics visible; wire input socket to top; weighs 140 gm.
Number Of Parts
1
Provenance
An attempt to synchronize the alatrical activity of the atria with the ventricular
events; first used in 1962; re in 1963-64; the was to vary the
ventricular rate with the body ; powered by 5 mercury batteries
Maker
cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1960
1969
circa 1960-1969
Date Remarks
Dr. Chiong's estimate
Material
plastic: transparent
metal: silver
Inscriptions
Name plate: ATRIAL INPUT // VENTR OUTPUT // ATRICOR // Synchronous Pacer //
cordis // MIAMI, FLORIDA // USA
Permanent Location
Storage Room 0010
0010-E6-1
Dimension Notes
Length 7.0 cm. x Depth 2.5 cm. x Diam. 5.7 cm.
Condition Remarks
Overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #1
Exhibit History
Dec. 1994
Pacemaker Exhibit - KGH Cardiology
Images
Less detail

349 records – page 1 of 35.