Skip header and navigation

Refine By

21 records – page 1 of 3.

Dates
1950
circa 1950
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
Accession Number
997034436
Description
Two 3.2-cm vitallium Barr's bolts in a sealed tubular package with squared stoppers and information pamphlet.
  2 images  
Accession Number
997034436
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
MeSH Heading
Orthopedic Fixation Devices
Fracture Fixation -- instrumentation
Tibial Fractures
Leg Injuries
Description
Two 3.2-cm vitallium Barr's bolts in a sealed tubular package with squared stoppers and information pamphlet.
Number Of Parts
1
Provenance
Used in the KGH operating room.
Maker
Howmedica
Site Made (City)
Rutherford
Site Made (State)
New Jersey
Site Made (Country)
United States of America
Dates
1950
circa 1950
Date Remarks
Vitallium used for surgical instruments from 1950 on.
Material
metal: silver
plastic: translucent green
paper: white
Inscriptions
"Howmedica Vitallium Alloy CAT NO 6554-0-014 " printed on label.
Permanent Location
Storage Room 0010
0010-E2-9
Dimension Notes
Length 15.1 cm x Width 2.2 cm x Depth 2.2 cm
Condition Remarks
Label on container is lifting up.
Copy Type
Original
Reference Types
Book
Internet
JPG
Reference Comments
"1983 Annual Product Catalogue," by Howmedica, p. H-17; Internet source "PubMed": www.pubmed.gov (please see attached photocopy); CD #5.
Research Facts
This bolt is used to stabilize a fractured tibia; the reference copy states: "Staged management of high-energy proximal tibia fractures: the results of a prospective, standardized protocol."
Images
Less detail
Dates
1950
circa 1950
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
Accession Number
997034431
Description
Threaded 89-mm-long vitallium Barr's bolt, including 7.8-cm shaft.
  1 image  
Accession Number
997034431
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
MeSH Heading
Orthopedic Fixation Devices
Fracture Fixation -- instrumentation
Tibial Fractures
Leg Injuries
Description
Threaded 89-mm-long vitallium Barr's bolt, including 7.8-cm shaft.
Number Of Parts
1
Provenance
Used in the KGH operating room.
Maker
Howmedica
Site Made (City)
Rutherford
Site Made (State)
New Jersey
Site Made (Country)
United States of America
Dates
1950
circa 1950
Date Remarks
Vitallium used for surgical instruments from 1950 on.
Material
metal: silver
Permanent Location
Storage Room 0010
0010-E2-9
Dimension Notes
Length 9.2 cm x Diam. 0.7 cm
Condition Remarks
No stains or corrosion.
Copy Type
Original
Reference Types
Book
Internet
JPG
Reference Comments
"1983 Annual Product Catalogue," by Howmedica, p. H-17; Internet source "PubMed": www.pubmed.gov ( please see attached photocopy); CD #5.
Research Facts
This bolt is used to stabilize a fractured tibia; the reference copy states: "Staged management of high-energy proximal tibia fractures: the results of a prospective, standardized protocol."
Images
Less detail
Dates
1950
circa 1950
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
Accession Number
997034433
Description
Threaded 57-mm-long vitallium Barr's bolt, including 1.7-cm shaft.
  1 image  
Accession Number
997034433
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
MeSH Heading
Orthopedic Fixation Devices
Fracture Fixation -- instrumentation
Tibial Fractures
Leg Injuries
Description
Threaded 57-mm-long vitallium Barr's bolt, including 1.7-cm shaft.
Number Of Parts
1
Provenance
Used in the KGH operating room.
Maker
Howmedica
Site Made (City)
Rutherford
Site Made (State)
New Jersey
Site Made (Country)
United States of America
Dates
1950
circa 1950
Date Remarks
Vitallium used for surgical instruments from 1950 on.
Material
metal: silver
Permanent Location
Storage Room 0010
0010-E2-9
Dimension Notes
Length 6.0 cm x Diam. 0.7 cm
Condition Remarks
No stains or corrosion.
Copy Type
Original
Reference Types
Book
Internet
JPG
Reference Comments
"1983 Annual Product Catalogue," by Howmedica, p. H-17; Internet source "PubMed": www.pubmed.gov ( please see attached photocopy); CD #5.
Research Facts
This bolt is used to stabilize a fractured tibia; the reference copy states: "Staged management of high-energy proximal tibia fractures: the results of a prospective, standardized protocol."
Images
Less detail
Dates
1950
circa 1950
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
Accession Number
997034434
Description
Threaded 64-mm-long vitallium Barr's bolt in sealed package with information pamphlet.
  2 images  
Accession Number
997034434
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
MeSH Heading
Orthopedic Fixation Devices
Fracture Fixation -- instrumentation
Tibial Fractures
Leg Injuries
Description
Threaded 64-mm-long vitallium Barr's bolt in sealed package with information pamphlet.
Number Of Parts
1
Provenance
Used in the KGH operating room.
Maker
Howmedica
Site Made (City)
Rutherford
Site Made (State)
New Jersey
Site Made (Country)
United States of America
Dates
1950
circa 1950
Date Remarks
Vitallium used for surgical instruments from 1950 on.
Material
metal: silver
plastic: clear
paper: white
Inscriptions
"CAT. NO 6554-0-024 Vitallium Alloy Howmedica" printed on label.
Permanent Location
Storage Room 0010
0010-E2-9
Dimension Notes
Length 11.5 cm x Width 6.4 cm x Depth 0.5 cm
Condition Remarks
Package is not damaged.
Copy Type
Original
Reference Types
Book
Internet
JPG
Reference Comments
"1983 Annual Product Catalogue," by Howmedica, p. H-17; Internet source "PubMed": www.pubmed.gov ( please see attached photocopy); CD #5.
Research Facts
This bolt is used to stabilize a fractured tibia; the reference copy states: "Staged management of high-energy proximal tibia fractures: the results of a prospective, standardized protocol."
Images
Less detail
Dates
1950
circa 1950
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
Accession Number
997034435
Description
Threaded vitallium Barr's bolt in a sealed package with informaiton pamphlet.
  2 images  
Accession Number
997034435
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
MeSH Heading
Orthopedic Fixation Devices
Fracture Fixation -- instrumentation
Tibial Fractures
Leg Injuries
Description
Threaded vitallium Barr's bolt in a sealed package with informaiton pamphlet.
Number Of Parts
1
Provenance
Used in the KGH operating room.
Maker
Howmedica
Site Made (City)
Rutherford
Site Made (State)
New Jersey
Site Made (Country)
United States of America
Dates
1950
circa 1950
Date Remarks
Vitallium used for surgical instruments from 1950 on.
Material
metal: silver
plastic: translucent green
paper: white
Inscriptions
"CAT NO 6554-0-016 Vitallium Alloy Howmedica" printed on label.
Permanent Location
Storage Room 0010
0010-E2-9
Dimension Notes
Length 13.2 cm x Width 2.9 cm x Depth 1.8 cm
Condition Remarks
Package is unopened.
Copy Type
Original
Reference Types
Book
Internet
JPG
Reference Comments
"1983 Annual Product Catalogue," by Howmedica, p. H-17; Internet source "PubMed": www.pubmed.gov ( please see attached photocopy); CD #5.
Research Facts
This bolt is used to stabilize a fractured tibia; the reference copy states: "Staged management of high-energy proximal tibia fractures: the results of a prospective, standardized protocol."
Images
Less detail
Dates
1950
circa 1950
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
Accession Number
997034438
Description
A threaded 95-mm vitallium Barr's bolt.
  1 image  
Accession Number
997034438
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
MeSH Heading
Orthopedic Fixation Devices
Fracture Fixation -- instrumentation
Tibial Fractures
Leg Injuries
Description
A threaded 95-mm vitallium Barr's bolt.
Number Of Parts
1
Provenance
Used in the KGH operating room.
Maker
Howmedica
Site Made (City)
Rutherford
Site Made (State)
New Jersey
Site Made (Country)
United States of America
Dates
1950
circa 1950
Date Remarks
Vitallium used for surgical instruments from 1950 on.
Material
metal: silver
Permanent Location
Storage Room 0010
0010-E2-9
Dimension Notes
Length 9.6 cm x Diam. 0.7 cm
Condition Remarks
No stains or corrosion.
Copy Type
Original
Reference Types
Book
Internet
JPG
Reference Comments
"1983 Annual Product Catalogue," by Howmedica, p. H-17; Internet source "PubMed": www.pubmed.gov (please see attached photocopy); CD #5.
Research Facts
This bolt is used to stabilize a fractured tibia; the reference copy states: "Staged management of high-energy proximal tibia fractures: the results of a prospective, standardized protocol."
Images
Less detail
Dates
1950
circa 1950
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
Accession Number
997034439
Description
A threaded 64-mm vitallium Barr's bolt.
  1 image  
Accession Number
997034439
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
MeSH Heading
Orthopedic Fixation Devices
Fracture Fixation -- instrumentation
Tibial Fractures
Leg Injuries
Description
A threaded 64-mm vitallium Barr's bolt.
Number Of Parts
1
Provenance
Used in the KGH operating room.
Maker
Howmedica
Site Made (City)
Rutherford
Site Made (State)
New Jersey
Site Made (Country)
United States of America
Dates
1950
circa 1950
Date Remarks
Vitallium used for surgical instruments from 1950 on.
Material
metal: silver
Permanent Location
Storage Room 0010
0010-E2-9
Dimension Notes
Length 6.5 cm x Diam. 0.7 cm
Condition Remarks
No stains or corrosion.
Copy Type
Original
Reference Types
Book
Internet
JPG
Reference Comments
"1983 Annual Product Catalogue," by Howmedica, p. H-17; Internet source "PubMed": www.pubmed.gov (please see attached photocopy); CD #5.
Research Facts
This bolt is used to stabilize a fractured tibia; the reference copy states: "Staged management of high-energy proximal tibia fractures: the results of a prospective, standardized protocol."
Images
Less detail
Dates
1950
circa 1950
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
Accession Number
997034440
Description
A threaded 57-mm vitallium Barr's bolt.
  1 image  
Accession Number
997034440
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
MeSH Heading
Orthopedic Fixation Devices
Fracture Fixation -- instrumentation
Tibial Fractures
Leg Injuries
Description
A threaded 57-mm vitallium Barr's bolt.
Number Of Parts
1
Provenance
Used in the KGH operating room.
Maker
Howmedica
Site Made (City)
Rutherford
Site Made (State)
New Jersey
Site Made (Country)
United States of America
Dates
1950
circa 1950
Date Remarks
Vitallium used for surgical instruments from 1950 on.
Material
metal: silver
Permanent Location
Storage Room 0010
0010-E2-9
Dimension Notes
Length 5.8 cm x Diam. 0.7 cm
Condition Remarks
No stains or corrosion.
Copy Type
Original
Reference Types
Book
Internet
JPG
Reference Comments
"1983 Annual Product Catalogue," by Howmedica, p. H-17; Internet source "PubMed": www.pubmed.gov (please see attached photocopy); CD #5.
Research Facts
This bolt is used to stabilize a fractured tibia; the reference copy states: "Staged management of high-energy proximal tibia fractures: the results of a prospective, standardized protocol."
Images
Less detail
Dates
1950
circa 1950
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
Accession Number
997034441
Description
A threaded 89-mm vitallium Barr's bolt.
  1 image  
Accession Number
997034441
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
MeSH Heading
Orthopedic Fixation Devices
Fracture Fixation -- instrumentation
Tibial Fractures
Leg Injuries
Description
A threaded 89-mm vitallium Barr's bolt.
Number Of Parts
1
Provenance
Used in the KGH operating room.
Maker
Howmedica
Site Made (City)
Rutherford
Site Made (State)
New Jersey
Site Made (Country)
United States of America
Dates
1950
circa 1950
Date Remarks
Vitallium used for surgical instruments from 1950 on.
Material
metal: silver
Permanent Location
Storage Room 0010
0010-E2-9
Dimension Notes
Length 9.0 cm x Diam. 0.7 cm
Condition Remarks
No stains or corrosion.
Copy Type
Original
Reference Types
Book
Internet
JPG
Reference Comments
"1983 Annual Product Catalogue," by Howmedica, p. H-17; Internet source "PubMed": www.pubmed.gov (please see attached photocopy); CD #5.
Research Facts
This bolt is used to stabilize a fractured tibia; the reference copy states: "Staged management of high-energy proximal tibia fractures: the results of a prospective, standardized protocol."
Images
Less detail
Dates
1950
circa 1950
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
Accession Number
997034442
Description
A threaded 102-mm vitallium Barr's bolt.
  1 image  
Accession Number
997034442
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Orthopedic Surgery
MeSH Heading
Orthopedic Fixation Devices
Fracture Fixation -- instrumentation
Tibial Fractures
Leg Injuries
Description
A threaded 102-mm vitallium Barr's bolt.
Number Of Parts
1
Provenance
Used in the KGH operating room.
Maker
Howmedica
Site Made (City)
Rutherford
Site Made (State)
New Jersey
Site Made (Country)
United States of America
Dates
1950
circa 1950
Date Remarks
Vitallium used for surgical instruments from 1950 on.
Material
metal: silver
Permanent Location
Storage Room 0010
0010-E2-9
Dimension Notes
Length 10.4 cm x Diam. 0.7 cm
Condition Remarks
No stains or corrosion.
Copy Type
Original
Reference Types
Book
Internet
JPG
Reference Comments
"1983 Annual Product Catalogue," by Howmedica, p. H-17; Internet source "PubMed": www.pubmed.gov (please see attached photocopy); CD #5.
Research Facts
This bolt is used to stabilize a fractured tibia; the reference copy states: "Staged management of high-energy proximal tibia fractures: the results of a prospective, standardized protocol."
Images
Less detail

21 records – page 1 of 3.