Skip header and navigation

Refine By

   MORE

9 records – page 1 of 1.

fetal heart rate probe

https://mhc.andornot.com/en/permalink/artifact1709
Dates
1994
circa 1994
Collection
Bladder Function Clinic Collection
Category
Diagnostic & Treatment Artifacts
Classification
Obstetrics
Accession Number
996013004
Description
(a) Sealed envelope with a clear plastic front, containing (b) a long plastic wand with a handle and a blue scale up the side of it; red and green wires criss-cross out the one end and one white plastic tube and one clear tube come out the same end; tubes have clear plastic ends; white plastic stop…
  1 image  
Accession Number
996013004
Collection
Bladder Function Clinic Collection
Category
Diagnostic & Treatment Artifacts
Classification
Obstetrics
MeSH Heading
MM= Exploring Instruments -- probe -- uterine
Description
(a) Sealed envelope with a clear plastic front, containing (b) a long plastic wand with a handle
and a blue scale up the side of it; red and green wires criss-cross out the one end and one white
plastic tube and one clear tube come out the same end; tubes have clear plastic ends; white plastic
stopper attached to clear tuble; (c) a separate clear and white plastic cylindrical plug is also
sealed in the envelope
Number Of Parts
1
Provenance
Used in Bladder Function Clinic at KGH
Maker
Corometrics Medical Systems Inc.
Site Made (City)
Wallingford
Site Made (State)
Connecticut
Site Made (Country)
United States of America
Dates
1994
circa 1994
Date Remarks
Used in Bladder Function Clinic between 1994 and 1995
Material
wire: red; green
plastic: white; clear
paper: white
Inscriptions
"WARNING" [listed] "CONTRAINDICATIONS" [listed] "CAUTION" [listed] "Corometrics // medical systems,
inc. // 61 Barnes Park Road North, Wallingford, CT. 06492 U.S.A. -- ECOSTERILIZED BIOLOGICALLY
TESTED // Sterile in Unopened, Undamaged Package // DO NOT REUSE OR RESTERILIZE LOT # // CPX1-2 //
USE BY 12/95 // QTY. (EA.) // 0.1 [scale on instrument]"
Permanent Location
Storage Room 0010
0010-D7-7
Dimension Notes
Length 39.3 cm. x Width 1.9 cm. x Depth 0.7 cm.
Condition Remarks
Unused in a sealed envelope
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. James A. Low; CD #1
Research Facts
Used to record fetal heart rate and measure uterine contractions
Images
Less detail

fetal heart rate probe

https://mhc.andornot.com/en/permalink/artifact1710
Dates
1994
circa 1994
Collection
Bladder Function Clinic Collection
Category
Diagnostic & Treatment Artifacts
Classification
Obstetrics
Accession Number
996013005
Description
Sealed envelope with a clear plastic front; long plastic wand with a handle and a blue scale up the side of it; red and green wires criss-cross out the one end and one white plastic tube and one clear tube come out the same end; tubes have clear plastic ends and white plastic stopper attached to cl…
  2 images  
Accession Number
996013005
Collection
Bladder Function Clinic Collection
Category
Diagnostic & Treatment Artifacts
Classification
Obstetrics
MeSH Heading
MM= Exploring Instruments -- probe -- uterine
Description
Sealed envelope with a clear plastic front; long plastic wand with a handle and a blue scale up
the side of it; red and green wires criss-cross out the one end and one white plastic tube and
one clear tube come out the same end; tubes have clear plastic ends and white plastic stopper attached
to clear tube
Number Of Parts
1
Provenance
Used in Bladder Function Clinic at KGH
Maker
Corometrics Medical Systems Inc.
Site Made (City)
Wallingford
Site Made (State)
Connecticut
Site Made (Country)
United States of America
Dates
1994
circa 1994
Date Remarks
Used in Bladder Function Clinic between 1994 and 1995.
Material
wire: red; green
plastic: white; clear
paper: white
Inscriptions
"WARNING" [listed] "CONTRAINDICATIONS" [listed] "CAUTION" [listed] "Corometrics // medical systems,
inc. // 61 Barnes Park Road North, Wallingford, CT. 06492 U.S.A. -- ECOSTERILIZED BIOLOGICALLY
TESTED // Sterile in Unopened, Undamaged Package // DO NOT REUSE OR RESTERILIZE LOT # // CPX1-2 //
USE BY 12/95 // QTY. (EA.) // 0.1 [scale on instrument]"
Permanent Location
Storage Room 0010
0010-D7-7
Dimension Notes
Length: 56.0 cm. x Width 10.3 cm x Depth 1.0 cm
Condition Remarks
Unused in a sealed envelope
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. James A. Low; CD #3
Research Facts
Used to record fetal heart rate and measure uterine contractions
Images
Less detail

fetal heart rate probe

https://mhc.andornot.com/en/permalink/artifact12437
Dates
1985
1995
circa 1985-1995
Collection
Kingston General Hospital OB/GYN Department Collection
Category
Diagnostic & Treatment Artifacts
Classification
Obstetrics
Accession Number
999029004
Description
Sealed envelope with clear plastic front, containing a long plastic wand with blue scaling up the side of it; red and green wires criss-cross out of end; clear plastic and white plastic tubes also come out the same end; tubes have clear plastic ends; white plastic stopper attached to clear tube; …
Accession Number
999029004
Collection
Kingston General Hospital OB/GYN Department Collection
Category
Diagnostic & Treatment Artifacts
Classification
Obstetrics
MeSH Heading
MM= Exploring Instruments -- probe -- uterine
Description
Sealed envelope with clear plastic front, containing a long plastic wand with blue scaling up the side of it; red and green wires criss-cross out of end; clear plastic and white plastic tubes also come out the same end; tubes have clear plastic ends; white plastic stopper attached to clear tube; unattached clear plastic stopper; unattached white plastic stopper
Number Of Parts
1
Provenance
Used in clinical trials for Corometrics at Kingston General Hospital
Maker
Corometrics
Site Made (City)
Wallingford
Site Made (State)
Connecticut
Site Made (Country)
United States of America
Dates
1985
1995
circa 1985-1995
Date Remarks
Based on label on package and donor remarks
Material
paper: cream
plastic: transclucent, white, red, green
ink: blue
metal: silver
Inscriptions
Printed on sticker on back of package, "WARNING" [listed] // "CONTRAINDICATIONS" [listed] // "CAUTION" [listed] // "COROMETRICS // MEDICAL SYSTEMS, INC. // 61 Barnes Park Road North, Wallingford, CT. 06492 U.S.A. // "EtO STERILIZED BIOLOGICALLY TESTED // STERILE IN UNOPENED, UNDAMAGED PACKAGE // DO NOT REUSE OR RESTERILIZE"; Printed on sticker on back of pacakge, " LOT # // CPX1-1 // USE BY 11/96 // QTY. (EA.) // 01".
Temporary Location
Workroom 2009
Dimension Notes
Length 56.1 cm x Width 10.2 cm x Depth 0.9 cm
Condition Remarks
Slight aging of packaging
Copy Type
Original
Reference Types
Person
Reference Comments
Dr. James Low
Research Facts
Used in clinical trials by Corometrics at Kingston General Hospital for measuring pressure of fetal heart rate.
Less detail

Sims uterine probe

https://mhc.andornot.com/en/permalink/artifact12212
Dates
1955
1965
circa 1955-1965
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Gynaecology
Accession Number
997034521
Description
Sims uterine probe consists of a long, solid metal rod that curves upwards at the distal end and has incremental measurement marks; tip is rounded and at the proximal end is a flat, oval, tab-style handle with diagonal grooves on one side.
  1 image  
Accession Number
997034521
Collection
Kingston General Hospital Operating Room Collection
Category
Diagnostic & Treatment Artifacts
Classification
Gynaecology
MeSH Heading
MM= Exploring Instruments -- probe -- uterine
Description
Sims uterine probe consists of a long, solid metal rod that curves upwards at the distal end and has incremental measurement marks; tip is rounded and at the proximal end is a flat, oval, tab-style handle with diagonal grooves on one side.
Number Of Parts
1
Provenance
Used in the KGH operating room.
Maker
Jette Scheerer
Site Made (Country)
Germany
Dates
1955
1965
circa 1955-1965
Date Remarks
Supplier's catalogue
Material
metal: silver
Permanent Location
Storage Room 0010
0010-D8-6
Dimension Notes
Length 29.5 cm x Width 1.7 cm x Depth 0.7 cm
Copy Type
Original
Reference Types
Book
JPG
Reference Comments
"Aesculap Jetter & Scheerer Surgical Instruments," Aesculap, 1960, p. 169 (similar to item #04-136) (see attached photocopy); CD #1.
Research Facts
Used to probe and measure the depth of the uterus.
Images
Less detail
Dates
1985
1995
circa 1985-1995
Collection
Kingston General Hospital OB/GYN Department Collection
Category
Diagnostic & Treatment Artifacts
Classification
Gynaecology
Accession Number
999029003
Description
Sealed envelope with clear plastic front, containing a clear plastic transducer.
Accession Number
999029003
Collection
Kingston General Hospital OB/GYN Department Collection
Category
Diagnostic & Treatment Artifacts
Classification
Gynaecology
MeSH Heading
Transducers
MM= Exploring Instruments -- probe -- uterine
Description
Sealed envelope with clear plastic front, containing a clear plastic transducer.
Number Of Parts
1
Provenance
Used at Kingston General Hospital
Maker
Corometrics
Site Made (City)
Wallingford
Site Made (State)
Connecticut
Site Made (Country)
United States of America
Dates
1985
1995
circa 1985-1995
Date Remarks
Based on donor remarks
Material
paper: cream
plastic: translucent
Inscriptions
Printed on sticker on front of package, "INVESTIGATIONAL DEVICE: // Federal Law Restricts This Device to Investigational Use // LOT #DOME1 // USE BEFORE 2/96".
Temporary Location
Workroom 2009
Dimension Notes
Length 12.7 cm x Width 11.5 cm x Depth 0.9 cm
Condition Remarks
Slight aging to packaging
Copy Type
Original
Reference Types
Person
Reference Comments
Dr. James Low
Research Facts
Item was to be used in clinical trials for Corometrics (now General Electric) at the Kingston General Hospital. This item was novel because the system of testing did not require an electrode on babies head.
Less detail
Dates
1985
1996
circa 1985-1996
Collection
Kingston General Hospital OB/GYN Department Collection
Category
Diagnostic & Treatment Artifacts
Classification
Gynaecology
Accession Number
999029001
Description
A transducer cap consists of one plastic cap in a sealed envelope with clear plastic front and paper back.
Accession Number
999029001
Collection
Kingston General Hospital OB/GYN Department Collection
Category
Diagnostic & Treatment Artifacts
Classification
Gynaecology
MeSH Heading
Transducers
MM= Exploring Instruments -- probe -- uterine
Description
A transducer cap consists of one plastic cap in a sealed envelope with clear plastic front and paper back.
Number Of Parts
1
Provenance
Used at Kingston General Hospital in OB/GYN department
Maker
Corometrics
Site Made (City)
Wallingford
Site Made (State)
Connecticut
Site Made (Country)
United States of America
Dates
1985
1996
circa 1985-1996
Date Remarks
Expiry date written on package is 1996.
Material
paper: cream
plastic: translucent
ink: black
Inscriptions
Printed on sticker on front of package, "INVESTIGATIONAL DEVICE: // Federal Law Restricts This Device to Investigational Use // LOT #DOME1 // USE BEFORE 2/96".
Permanent Location
Storage Room 0010
0010-D7-7
Dimension Notes
Length 12.7 cm x Width 11.5 cm x Depth 0.9 cm
Condition Remarks
Slight yellowing of paper label on packaging.
Copy Type
Original
Reference Types
Person
Reference Comments
Dr. James Low
Research Facts
Item was to be used in clinical trials for Corometrics (now General Electric) at the Kingston General Hospital. The transducer cap attached to a transducer which measured the pressure from the balloon attached to a fetal heart rate probe.
Less detail
Dates
1985
1996
circa 1985-1996
Collection
Kingston General Hospital OB/GYN Department Collection
Category
Diagnostic & Treatment Artifacts
Classification
Gynaecology
Accession Number
999029002
Description
A transducer cap consisting of one plastic cap in a sealed envelope with clear plastic front and paper back.
Accession Number
999029002
Collection
Kingston General Hospital OB/GYN Department Collection
Category
Diagnostic & Treatment Artifacts
Classification
Gynaecology
MeSH Heading
Transducers
MM= Exploring Instruments -- probe -- uterine
Description
A transducer cap consisting of one plastic cap in a sealed envelope with clear plastic front and paper back.
Number Of Parts
1
Provenance
Used at Kingston General Hospital in OB/GYN department
Maker
Corometrics
Site Made (City)
Wallingford
Site Made (State)
Connecticut
Site Made (Country)
United States of America
Dates
1985
1996
circa 1985-1996
Date Remarks
Expiry date written on package is 1996.
Material
paper: cream
plastic: translucent
ink: black
Inscriptions
Printed on sticker on front of package, "INVESTIGATIONAL DEVICE: // Federal Law Restricts This Device to Investigational Use // LOT #DOME1 // USE BEFORE 2/96".
Permanent Location
Storage Room 0010
0010-D7-7
Dimension Notes
Length 12.7 cm x Width 11.5 cm x Depth 0.9 cm
Condition Remarks
Slight yellowing of paper label on packaging.
Copy Type
Original
Reference Types
Person
Reference Comments
Dr. James Low
Research Facts
Item was to be used in clinical trials for Corometrics (now General Electric) at the Kingston General Hospital. The transducer cap attached to a transducer which measured the pressure from the balloon attached to a fetal heart rate probe.
Less detail
Collection
Queen's University Faculty of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Gynaecology
Accession Number
997001142
Description
Uterine probe, which consists of a long, narrow instrument made from a single piece of solid metal; the handle is flat with rounded sides; the end of the handle is round, then tapers in, then back out again, then in again to join with the blade; the blade is long, flexible and cylindrical, and tape…
  3 images  
Accession Number
997001142
Collection
Queen's University Faculty of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Gynaecology
MeSH Heading
MM= Exploring Instruments -- probe -- uterine
Description
Uterine probe, which consists of a long, narrow instrument made from a single piece of solid metal; the handle is flat with rounded sides; the end of the handle is round, then tapers in, then back out again, then in again to join with the blade; the blade is long, flexible and cylindrical, and tapers slightly to a blunted tip; the tip end of the probe curves upwards
Number Of Parts
1
Provenance
Collected by Dr. A.A. Travill for the Queen's University Faculty of Medicine Collection
Maker
F.G. Otto & Sons
Site Made (State)
New York
Site Made (Country)
United States of America
Material
metal: silver
Inscriptions
The top of the handle has "6 // 1 // F.G. OTTO & SONS // N.Y." stamped into the metal
Permanent Location
Storage Room 0010
0010-D8-6
Dimension Notes
Length 28.1 cm x Width 2.2 cm x Depth 3.4 cm
Condition Remarks
The metal shows some wear; the metal of the handle shows minor corrosion; there was some tape residue on the probe after masking tape used to hold a tag onto the instrument was removed
Copy Type
Original
Reference Types
Person
Document
JPG
Reference Comments
Previous number #238; Faculty of Medicine Collection 1984 Inventory; Dr. J.A. Low; CD #3
Images
Less detail
Collection
Queen's University Faculty of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Gynaecology
Accession Number
997001145
Description
Uterine probe, which consists of a long, narrow instrument made from a single piece of solid plated metal; the handle is cylindrical, with six flattened sides and a rounded end; the other end of the handle tapers to join a flexible cylindrical blade, which has been bent several times; the tip end o…
  1 image  
Accession Number
997001145
Collection
Queen's University Faculty of Medicine Collection
Category
Diagnostic & Treatment Artifacts
Classification
Gynaecology
MeSH Heading
Gynecology
MM= Exploring Instruments -- probe -- uterine
Description
Uterine probe, which consists of a long, narrow instrument made from a single piece of solid plated metal; the handle is cylindrical, with six flattened sides and a rounded end; the other end of the handle tapers to join a flexible cylindrical blade, which has been bent several times; the tip end of the blade is squared off and ends with a blunted tip; the tip end of the probe curves upwards
Number Of Parts
1
Provenance
Collected by Dr. A.A. Travill for the Queen's University Faculty of Medicine Collection
Material
metal: silver; grey
Inscriptions
None
Permanent Location
Storage Room 0010
0010-D8-6
Dimension Notes
Length 22.4 cm x Width 0.7 cm x Depth 2.8 cm
Condition Remarks
The metal shows wear, and plating is worn off in several spots; no corrosion is visible; there was some tape residue on the probe after masking tape used to hold a tag onto the instrument was removed; #2: metal tarnished
Copy Type
Original
Reference Types
Document
Person
JPG
Reference Comments
Previous number #241; Faculty of Medicine Collection 1984 Inventory; Dr. J.A. Low; CD #5
Images
Less detail

9 records – page 1 of 1.