Skip header and navigation

Refine By

83 records – page 1 of 5.

Atricor synchronous pacer

https://mhc.andornot.com/en/permalink/artifact86
Dates
1960
1969
circa 1960-1969
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007031
Description
Circular form; transparent encased ; steel name plate to front surface; inner mechanics visible; wire input socket to top; weighs 140 gm.
  2 images  
Accession Number
994007031
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Circular form; transparent encased ; steel name plate to front surface; inner mechanics visible; wire input socket to top; weighs 140 gm.
Number Of Parts
1
Provenance
An attempt to synchronize the alatrical activity of the atria with the ventricular
events; first used in 1962; re in 1963-64; the was to vary the
ventricular rate with the body ; powered by 5 mercury batteries
Maker
cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1960
1969
circa 1960-1969
Date Remarks
Dr. Chiong's estimate
Material
plastic: transparent
metal: silver
Inscriptions
Name plate: ATRIAL INPUT // VENTR OUTPUT // ATRICOR // Synchronous Pacer //
cordis // MIAMI, FLORIDA // USA
Permanent Location
Storage Room 0010
0010-E6-1
Dimension Notes
Length 7.0 cm. x Depth 2.5 cm. x Diam. 5.7 cm.
Condition Remarks
Overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #1
Exhibit History
Dec. 1994
Pacemaker Exhibit - KGH Cardiology
Images
Less detail

Atricor synchronous pacer

https://mhc.andornot.com/en/permalink/artifact87
Dates
1960
1969
circa 1960-1969
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007032
Description
Circular form; transparent encased ; steel name plate to front surface; inner mechanics visible; wire input socket to top; weighs 140 g.
  2 images  
Accession Number
994007032
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Circular form; transparent encased ; steel name plate to front surface; inner mechanics visible; wire input socket to top; weighs 140 g.
Number Of Parts
1
Provenance
An attempt to synchronize the alatrical activity of the atria with the ventricular
events; first used in 1962; re in 1963-64; the was to vary the
ventricular rate with the body ; powered by 5 mercury batteries
Maker
cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1960
1969
circa 1960-1969
Date Remarks
Dr. Chiong's estimate
Material
plastic: transparent
metal: silver
Inscriptions
Name plate: ATRIAL INPUT // VENTR OUTPUT // ATRICOR // Synchronous Pacer //
cordis // MIAMI, FLORIDA // USA
Permanent Location
Storage Room 0010
0010-E6-1
Dimension Notes
Length 7.0 cm. x Depth 2.5 cm. x Diam. 5.7 cm.
Condition Remarks
Overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #1
Exhibit History
Dec. 1994
Pacemaker Exhibit - KGH Cardiology
Images
Less detail
Dates
1970
1979
circa 1970-1979
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007153
Description
Internal pacemaker; rectangular shape; stainless steel; translucent yellow plastic attachment to top; with insert to one end for wire; maker name and model information engraved to front surface
  1 image  
Accession Number
994007153
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rectangular shape; stainless steel; translucent yellow
plastic attachment to top; with insert to one end for wire; maker name and
model information engraved to front surface
Number Of Parts
1
Maker
Medcor
Site Made (City)
Hollywood
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1970
1979
circa 1970-1979
Date Remarks
estimate
Material
metal: silver
plastic: yellow
Inscriptions
Engraved to front: "ESB / Medcor // DEMAND PACER // (R-INHIBITED) // ICHD TYPE
MODEL 3-70C // SN G3769B // HOLLYWOOD, FL, USA"
Permanent Location
Storage Room 0010
0010-E6-2
Dimension Notes
Length: 7.5 cm. x Width: 5.0 cm. x Depth: 1.3 cm.
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #4
Exhibit History
"Pacemakers: Technology Development," HDH, 14 Feb. 2007
Images
Less detail

dental auto-mallet

https://mhc.andornot.com/en/permalink/artifact13403
Dates
1943
1950
circa 1943-1950
Collection
Dr. Ralph and Mrs. Olga Crawford Canadian Dental Collection
Category
Diagnostic & Treatment Artifacts
Classification
Dental
Accession Number
010020281 a-k
Description
McKenzie automatic amalgam condenser; clear rectangular plastic holder (a) with spaces for handpiece, condenser points; silver metal handpiece (b) with specially-designed black metal latch over tip; concentric ridged circles along bottom half, before cylindrical handpiece curves at a slight angle, …
  4 images  
Accession Number
010020281 a-k
Collection
Dr. Ralph and Mrs. Olga Crawford Canadian Dental Collection
Category
Diagnostic & Treatment Artifacts
Classification
Dental
MeSH Heading
Dental Instruments
MM= Dentistry, Operative -- mallet
Description
McKenzie automatic amalgam condenser; clear rectangular plastic holder (a) with spaces for handpiece, condenser points; silver metal handpiece (b) with specially-designed black metal latch over tip; concentric ridged circles along bottom half, before cylindrical handpiece curves at a slight angle, ending with a round opening; six silver metal condenser points fit into handpiece; one with curved end (c), one with oval end (d), one with flaring round, flat end (e), one with rounded, circular end (f), two with flat, round ends (g, h); two cylindrical driving cams (i, j) hold points in handpiece; white rectangular instruction sheet (k), printed with black ink on one side, states product's advantages, parts and directions
Number Of Parts
11
Part Names
a - holder - Size: Length 9.3 cm x Width 3.1 cm x Depth 0.9 cm
b - handpiece - Size: Length 8.2 cm x Width 1.5 cm x Depth 1.0 cm
c - condenser point - Size: Length 1.7 cm x Width 0.4 cm x Depth 0.2 cm
d - condenser point - Size: Length 1.7 cm x Width 0.3 cm x Depth 0.2 cm
e - condenser point - Size: Length 1.7 cm x Diam. 0.3 cm
f - condenser point - Size: Length 1.7 cm x Diam. 0.2 cm
g - condenser point - Size: Length 1.7 cm x Diam. 0.2 cm
h - condenser point - Size: Length 1.7 cm x Diam. 0.2 cm
i - cam - Size: Length 0.5 cm x Diam. 0.2 cm
j - cam - Size: Length 0.5 cm x Diam. 0.2 cm
k - sheet - Size: Length 27.9 cm x Width 9.2 cm x Depth 0.1 cm
Provenance
Transfer from the Dental Canada Fund; previously housed in the Dentistry Canada Museum (Ottawa)
Maker
Facility Products
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1943
1950
circa 1943-1950
Date Remarks
Based on patent date
Material
metal: silver, black
plastic: clear
paper: white
ink: black
Inscriptions
(b) Engraved near bottom: "THE DENTAL SPECIALTY MFG. CO"
Permanent Location
(a-j): Storage Room 0010
0010-B
(k): Storage Room 2005
2005-2-5 Box 22
Condition Remarks
Sheet (k) is worn at edges, folds; metal on (b) tarnished
Copy Type
Original
Reference Types
Person
Internet
JPG
Reference Comments
James G. Brass; "Free Patents Online" website
CD #1
Research Facts
Dr Ralph and Mrs Olga Crawford donated their extensive Canadian dental collection to the DCF to create the museum in 1997; further donations were received while Dr Crawford was Curator Emeritus at the Dental Canada Museum until its closure in 2008; this item was donated by Dr. James G. Brass from Comox, British Columbia; his father was a classmate of the inventor of this product, Olin G. McKenzie, at Northwestern University in the late 1930s; this item was patented in 1943; its primary objective was to provide a simple and efficient plugger construction which can be used in an ordinary drilling handpiece, specifically only with a change in the latch, not the handpiece itself
Images
Less detail

dietary supplement

https://mhc.andornot.com/en/permalink/artifact10572
Collection
Dr. A. Morales Collection
Category
Pharmacy and Drug Artifacts
Classification
Pharmacy, Other
Accession Number
004001006
Description
An empty pill bottle.
  2 images  
Accession Number
004001006
Collection
Dr. A. Morales Collection
Category
Pharmacy and Drug Artifacts
Classification
Pharmacy, Other
MeSH Heading
Impotence -- drug therapy
MM= Drug Packaging -- container -- bottle
Description
An empty pill bottle.
Number Of Parts
1
Provenance
Owned and used by Dr. A. Morales, Kingston General Hospital Urology Dept.
Maker
Jag Enterprises
Site Made (City)
Seminole
Site Made (State)
Florida
Site Made (Country)
United States of America
Material
plastic: white
paper: blue; white
Inscriptions
"Stay Erect™ // Our Name Says it all // MSPF // Male Sexual // Performance // Formula™"; plus other product information.
Permanent Location
Storage Room 0010
0010-A5-4 Box 5 Row C
Dimension Notes
Length 9.3 cm x Diam. 4.6 cm
Condition Remarks
Very light wear on label and top only.
Copy Type
Original
Reference Types
Document
Reference Comments
Dr. Morales's notes
Research Facts
Herbal pill advertised as enhancing male sexual performance.
Images
Less detail

Ectocor standby pacer

https://mhc.andornot.com/en/permalink/artifact242
Dates
1967
1973
circa 1967-1973
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007187
Description
Internal pacemaker; circular shape; inner mechanics potted in translucent yellow plastic casing; stainless steel nameplate to front; insert for wires to top; maker name and model information engraved to nameplate
  2 images  
Accession Number
994007187
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; circular shape; inner mechanics potted in translucent yellow
plastic casing; stainless steel nameplate to front; insert for wires to top;
maker name and model information engraved to nameplate
Number Of Parts
1
Maker
cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1967
1973
circa 1967-1973
Date Remarks
Dr. Chiong's notes; original record had "late 1960s - early 1970s"
Material
plastic: yellow
metal: silver
Inscriptions
Engraved to nameplate: VENTR. OUTPUT // ECTOCOR // STANDBY PACER //
129E-5931 // RATE-70 // cordis // MIAMI, FLORIDA
Permanent Location
Storage Room 0010
0010-E6-1
Dimension Notes
Length: 6.8 cm. x Width: 5.8 cm. x Depth: 2.4 cm.
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #4
Images
Less detail

Ectocor standby pacer

https://mhc.andornot.com/en/permalink/artifact244
Dates
1960
circa 1960
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007189
Description
Internal pacemaker; circular shape; inner mechanics potted in translucent yellow plastic casing; stainless steel nameplate to front; insert for wires to top; maker name and model information engraved to nameplate
  2 images  
Accession Number
994007189
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; circular shape; inner mechanics potted in translucent yellow
plastic casing; stainless steel nameplate to front; insert for wires to top;
maker name and model information engraved to nameplate
Number Of Parts
1
Maker
cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1960
circa 1960
Date Remarks
Dr. Chiong's notes
Material
plastic: yellow
metal: silver
Inscriptions
Engraved to nameplate: INPUT-OUTPUT // ECTOCOR // STANDBY PACER // RATE 70 //
129E7-10912 // cordis // MIAMI, FLORIDA // USA
Permanent Location
Storage Room 0010
0010-E6-1
Dimension Notes
Length: 6.8 cm. x Width: 5.8 cm. x Depth: 2.4 cm.
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #4
Images
Less detail

Extended-range Omni-Stanicor cardiac pacer

https://mhc.andornot.com/en/permalink/artifact168
Dates
1977
circa 1977
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007113
Description
Internal pacemaker; circular shape; inner mechanics contained in translucent yellow plastic casing; with rubber-coated wire inserted to top; stainless steel plate to front; with maker's name and information imprinted to plate
  2 images  
Accession Number
994007113
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; circular shape; inner mechanics contained in translucent yellow
plastic casing; with rubber-coated wire inserted to top; stainless steel plate to
front; with maker's name and information imprinted to plate
Number Of Parts
1
Maker
cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1977
circa 1977
Date Remarks
Dr. Chiong's notes
Material
metal: silver
plastic: yellow
Inscriptions
Imprinted to front: "Extended-Range // Omni-Stanicor (R) // R-Wave
Inhibited // Programmable Cardiac Pacer // 162E - 56368 //
cordis (R) // Miami, Fla., U.S.A."
Permanent Location
Storage Room 0010
0010-E6-1
Dimension Notes
Length: 6.8 cm. x Width: 6.0 cm. x Depth: 2.5 cm. x Diam. : 6.0 cm.
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #6
Images
Less detail

Extended-range Omni-Stanicor cardiac pacer

https://mhc.andornot.com/en/permalink/artifact169
Dates
1977
circa 1977
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007114
Description
Internal pacemaker; circular shape; inner mechanics contained in translucent yellow plastic casing; with rubber-coated wire inserted to top; stainless steel plate to front; with maker's name and information imprinted to plate
  2 images  
Accession Number
994007114
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; circular shape; inner mechanics contained in translucent yellow
plastic casing; with rubber-coated wire inserted to top; stainless steel plate to
front; with maker's name and information imprinted to plate
Number Of Parts
1
Maker
cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1977
circa 1977
Date Remarks
Dr. Chiong's notes
Material
metal: silver
plastic: yellow
Inscriptions
Imprinted to front: "Extended-Range // Omni-Stanicor (R) // R-Wave
Inhibited // Programmable Cardiac Pacer // 162E - 43585 //
cordis (R) // Miami, Fla., U.S.A."
Permanent Location
Storage Room 0010
0010-E6-1
Dimension Notes
Length: 6.8 cm. x Width: 6.0 cm. x Depth: 2.5 cm. x Diam. : 6.0 cm.
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #6
Images
Less detail

Extended-range Omni-Stanicor lambda cardiac pacer

https://mhc.andornot.com/en/permalink/artifact174
Dates
1976
circa 1976
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007119
Description
Internal pacemaker; oblong shape; stainless steel; translucent yellow plastic attachment to top; with insert for wire to one end of attachment; maker name and information imprinted to front surface
  3 images  
Accession Number
994007119
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; oblong shape; stainless steel; translucent yellow
plastic attachment to top; with insert for wire to one end of attachment;
maker name and information imprinted to front surface
Number Of Parts
1
Maker
cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1976
circa 1976
Date Remarks
Dr. Chiong's notes
Material
metal: silver
plastic: yellow
Inscriptions
Imprinted to front: "Extended-Range // Omni-Stanicor (R) (lambda) // LithiumPowered
// Programmable // R-Wave Inhibited // Cardiac Pacer //
190E - 51307 // cordis (R) // Miami, Fla., U.S.A."
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 6.8 cm. x Width: 5.7 cm. x Depth: 2.0 cm.
Condition Remarks
overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #7
Images
Less detail

Extended-range Omni-Stanicor lambda cardiac pacer

https://mhc.andornot.com/en/permalink/artifact175
Dates
1976
circa 1976
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007120
Description
Internal pacemaker; oblong shape; stainless steel; translucent yellow plastic attachment to top; with wire inserted to one end of attachment; maker name and information imprinted to front surface of attachment
  2 images  
Accession Number
994007120
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; oblong shape; stainless steel; translucent yellow
plastic attachment to top; with wire inserted to one end of attachment;
maker name and information imprinted to front surface of attachment
Number Of Parts
1
Maker
cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1976
circa 1976
Date Remarks
Dr. Chiong's notes
Material
metal: silver
plastic: yellow
Inscriptions
Imprinted to front: "Extended-Range // Omni-Stanicor (R) (lambda) // LithiumPowered
// Programmable // R-Wave Inhibited // Cardiac Pacer //
190E - 55412 // cordis (R) // Miami, Fla., U.S.A."
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 6.8 cm. x Width: 5.7 cm. x Depth: 2.0 cm.
Condition Remarks
overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD 36
Images
Less detail

Gemini III cardiac pacer

https://mhc.andornot.com/en/permalink/artifact125
Dates
Dec. 1983
circa Dec. 1983
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007070
Description
Internal pacemaker; rounded shape; stainless steel; translucent yellow plastic attachment to top; with two rubber-coated wires inserted to one side of attachment; maker name and information imprinted to front surface
  2 images  
Accession Number
994007070
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rounded shape; stainless steel; translucent yellow plastic
attachment to top; with two rubber-coated wires inserted to one side of attachment;
maker name and information imprinted to front surface
Number Of Parts
1
Maker
cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
Dec. 1983
circa Dec. 1983
Date Remarks
Dr. Chiong's notes
Material
metal: silver
plastic: yellow
Inscriptions
Imprinted to front: "Gemini (R) III // Automatic Universal (DDD) // Cardiac
Pacer // SN418A - 44455 // cordis (R) // Miami, FL, U.S.A."
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 6.0 cm. x Width: 5.9 cm. x Depth: 1.0 cm.
Condition Remarks
overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #4
Images
Less detail

Gemini III cardiac pacer

https://mhc.andornot.com/en/permalink/artifact126
Dates
1983
circa 1983
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007071
Description
Internal pacemaker; rounded shape; stainless steel; translucent plastic attachment to top; with two wires inserted to one side; maker name and information imprinted to front surface
  2 images  
Accession Number
994007071
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rounded shape; stainless steel; translucent plastic
attachment to top; with two wires inserted to one side; maker name and
information imprinted to front surface
Number Of Parts
1
Maker
cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1983
circa 1983
Date Remarks
Dr. Chiong's notes
Material
metal: silver
plastic: yellow
Inscriptions
Imprinted to front: "Gemini (R) III // Automatic Universal (DDD) // Cardiac
Pacer // SN418A - 44501 // cordis (R) // Miami, FL, U.S.A."
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 6.0 cm. x Width: 5.9 cm. x Depth: 1.0 cm.
Condition Remarks
overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #6
Images
Less detail

Gemini III cardiac pacer

https://mhc.andornot.com/en/permalink/artifact127
Dates
1983
circa 1983
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007072
Description
Internal pacemaker; rounded shape; stainless steel; translucent yellow plastic attachment to top (insert for wires); maker's name and information imprinted to front surface
  2 images  
Accession Number
994007072
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rounded shape; stainless steel; translucent yellow plastic
attachment to top (insert for wires); maker's name and information
imprinted to front surface
Number Of Parts
1
Maker
cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1983
circa 1983
Date Remarks
Dr. Chiong's notes
Material
metal: silver
plastic: yellow
Inscriptions
Imprinted to front: "Gemini (R) III // Lithium-Powered // Automatic Universal
(DDD) // Cardiac Pacer // SN418A - 43183 // cordis (R) // Miami, FL, U.S.A."
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 6.0 cm. x Width: 4.8 cm. x Depth: 1.0 cm.
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #6
Images
Less detail

Gemini theta cardiac pacer

https://mhc.andornot.com/en/permalink/artifact128
Dates
Apr. 1982
circa Apr. 1982
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007073
Description
Internal pacemaker; rounded oblong shape; stainless steel; translucent yellow plastic attachment to top; with two rubber-coated wires inserted to one side of attachment; maker's name and information imprinted to front surface
  2 images  
Accession Number
994007073
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rounded oblong shape; stainless steel; translucent yellow
plastic attachment to top; with two rubber-coated wires inserted to one side
of attachment; maker's name and information imprinted to front surface
Number Of Parts
1
Maker
cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
Apr. 1982
circa Apr. 1982
Date Remarks
Dr. Chiong's notes
Material
metal: silver
plastic: yellow
Inscriptions
Imprinted to front: "Gemini (R) (theta) // Lithium-Powered // Automatic Universal
(DDD) // Cardiac Pacer // SN415A - 18411 // cordis (R) // Miami, FL, U.S.A."
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 7.0 cm. x Width: 6.0 cm. x Depth: 1.4 cm.
Condition Remarks
overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #6
Exhibit History
May 24 - Sept. 13, 2001: Agnes Etherington Art Centre Museopathy exhibit
Images
Less detail

Gemini theta cardiac pacer

https://mhc.andornot.com/en/permalink/artifact129
Dates
1982
circa 1982
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007074
Description
Internal pacemaker; rounded oblong shape; stainless steel; translucent yellow plastic attachment to top; with two rubber-coated wires inserted to one side of attachment; maker's name and information imprinted to front surface
  2 images  
Accession Number
994007074
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; rounded oblong shape; stainless steel; translucent yellow
plastic attachment to top; with two rubber-coated wires inserted to one side
of attachment; maker's name and information imprinted to front surface
Number Of Parts
1
Maker
cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1982
circa 1982
Date Remarks
Dr. Chiong's notes
Material
metal: silver
plastic: yellow
Inscriptions
Imprinted to front: "Gemini (R) (theta) // Lithium-Powered // Automatic Universal
(DDD) // Cardiac Pacer // SN415A - 18379 // cordis (R) // Miami, FL, U.S.A."; masking tape on back had "11938" written on it (now removed)
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 7.0 cm. x Width: 6.0 cm. x Depth: 1.4 cm.
Condition Remarks
overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #6
Images
Less detail

Gemini theta cardiac pacer

https://mhc.andornot.com/en/permalink/artifact130
Dates
1982
circa 1982
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007075
Description
Internal pacemaker; oblong shape; stainless steel; translucent yellow plastic attachment to top (insert for wires); maker name and information imprinted to front surface
  1 image  
Accession Number
994007075
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; oblong shape; stainless steel; translucent yellow
plastic attachment to top (insert for wires); maker name and information
imprinted to front surface
Number Of Parts
1
Maker
cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1982
circa 1982
Date Remarks
Dr. Chiong's notes
Material
metal: silver
plastic: yellow
Inscriptions
Imprinted to front:" Gemini (theta) // Lithium-Powered // Automatic Universal
(DDD) // Cardiac Pacer // SN415A - 2884 // cordis (R) // Miami, FL, U.S.A."
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 7.0 cm. x Width: 6.0 cm. x Depth: 1.4 cm.
Condition Remarks
overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #4
Images
Less detail

graduated set of Curvlite rectal dilators

https://mhc.andornot.com/en/permalink/artifact14732
Dates
1920
1960
circa 1920-1960
Category
Diagnostic & Treatment Artifacts
Home Health Care
Classification
Proctology
Treatment, General
Accession Number
016022049
Description
Black cardboard box with separate lid (a-b) has dividers for four graduated sizes of clear plastic rectal dilators (c - f); dilators are one piece crystal clear plastic and are boilable and unbreakable; box lid has decorative Curvlite logo in gold; design is without air vents; a set of four "torped…
  5 images  
Accession Number
016022049
Category
Diagnostic & Treatment Artifacts
Home Health Care
Classification
Proctology
Treatment, General
MeSH Heading
Rectum
Hemorrhoids
Description
Black cardboard box with separate lid (a-b) has dividers for four graduated sizes of clear plastic rectal dilators (c - f); dilators are one piece crystal clear plastic and are boilable and unbreakable; box lid has decorative Curvlite logo in gold; design is without air vents; a set of four "torpedolike" instruments varying in diameter from 1/2 to 1 inch and in length from 3 to 4 inches.
Number Of Parts
6
Part Names
a - box top - Length 14.5 cm x Width 12.2 cm x Depth 4.1 cm
b - box bottom - Length 14.3 cm x Width 11.9 cm x Depth 3.8 cm
c - dilator - Length 9.3 cm x Diam 2.0 cm
d - dilator - Length 9.8 cm x Diam 2.5 cm
e - dilator - Length 11.7 cm x Diam 2.8 cm
f - dilator - Length 11.3 cm x Diam 3.3 cm
Maker
Curvlite Surgical Product Company
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1920
1960
circa 1920-1960
Material
plastic: clear
paper: black, cream
Inscriptions
Printed on box lid: CURVLITE // REG. U.S. PAT. OFF."
Permanent Location
Storage Room 0010
0010-E8-10
Unit Of Measure
centimeters
Dimension Notes
Diameter measurements are at the widest part of the dilator
Copy Type
original
Reference Types
Internet
Research Facts
While similar to Dr. Young’s Rectal Dilators, Curvlite dilators were prescribed for the relief of hemorrhoids, constipation and other rectal maladies.
Images
Less detail

Multicor gamma pacemaker

https://mhc.andornot.com/en/permalink/artifact139
Dates
Jul-80
circa July 1980
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007084
Description
Internal pacemaker; oval shape; stainless steel; translucent yellow attachment to top; with insert for wire to one end of attachment; maker name and information imprinted to front surface
  2 images  
Accession Number
994007084
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; oval shape; stainless steel; translucent yellow
attachment to top; with insert for wire to one end of attachment; maker
name and information imprinted to front surface
Number Of Parts
1
Maker
cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
Jul-80
circa July 1980
Date Remarks
Dr. Chiong's notes
Material
metal: silver
plastic: yellow
Inscriptions
Imprinted to front surface: "Multicor (gamma) // VVI / VVT / VOO // MultiProgrammable
// SN337A-11593 // cordis (R) // Miami, Fla U.S.A."
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 5.8 cm. x Width: 4.8 cm. x Depth: 0.9 cm.
Condition Remarks
overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #6
Images
Less detail

Multicor gamma pacemaker

https://mhc.andornot.com/en/permalink/artifact140
Dates
1980
circa 1980
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
Accession Number
994007085
Description
Internal pacemaker; oval shape; stainless steel; translucent yellow attachment to top; with insert for wire to one end of attachment; maker name and information imprinted to front surface; previous # sticker to front
  1 image  
Accession Number
994007085
Collection
Dr. Rocky O. West Cardiology Collection
Category
Diagnostic & Treatment Artifacts
Classification
Cardiology
MeSH Heading
Pacemaker, Artificial
Cardiac Pacing, Artificial -- instrumentation
Cardiovascular Diseases -- therapy
Cardiology -- instrumentation
Description
Internal pacemaker; oval shape; stainless steel; translucent yellow
attachment to top; with insert for wire to one end of attachment; maker
name and information imprinted to front surface; previous # sticker to front
Number Of Parts
1
Maker
cordis
Site Made (City)
Miami
Site Made (State)
Florida
Site Made (Country)
United States of America
Dates
1980
circa 1980
Date Remarks
Dr. Chiong's notes
Material
metal: silver
plastic: yellow
Inscriptions
Imprinted to front surface: "Multicor (gamma) // VVI / VVT / VOO // Unipolar // Multi-Programmable // SN337A-15336 // cordis (R) // Miami, Fla U.S.A."
Permanent Location
Storage Room 0010
0010-E6-3
Dimension Notes
Length: 5.8 cm. x Width: 4.8 cm. x Depth: 0.9 cm.
Condition Remarks
overall condition good
Copy Type
Original
Reference Types
Person
JPG
Reference Comments
Dr. Chiong; CD #4
Images
Less detail

83 records – page 1 of 5.