Rockwood / Kingston Psychiatric Hospital / Providence Continuing Care Centre Collection
Category
Diagnostic & Treatment Artifacts
Classification
Anaesthesia
Accession Number
000003388 a-j
Description
Ohio 30/70 proportioner anaesthesia (a) machine consits of a metal frame on casters with three (b-d) drawers at the bottom; a metal counter-top supports a control panel with dials and Standard Flowmeter Shield as well as a Standard Trolley Bar with 2 Vaporizer arrangment which holds an Ethrane Vapo…
Ohio 30/70 proportioner anaesthesia (a) machine consits of a metal frame on casters with three (b-d) drawers at the bottom; a metal counter-top supports a control panel with dials and Standard Flowmeter Shield as well as a Standard Trolley Bar with 2 Vaporizer arrangment which holds an Ethrane Vaporizer and a Halothane Vaporizer; trolley bar also supports a Blood Pressure Manometer; machine frame has six gas valves and a hollow post for holding an Absorber; (e) a set of two keys opens and locks the the top drawer from behind machine; artefact also comes with five (f-j) instructional manuals and multiple attachments and breathing masks catalogued separately.
Number Of Parts
10
Part Names
a - machine - Size: Length 140.5 cm x Width 70.0 cm x Depth 62.0 cm
b-d - drawer - Size: Length 45.0 cm x Width 38.0 cm x Depth 12.5 cm
e - set of two keys - Size: Length 6.0 cm x Width 2.5 cm x Depth 1.5 cm
f-j - instruction manual - Size: Length 28.0 cm x Width 21.5 cm x Depth 0.3 cm
Printed on label affixed to front of machine: "Ohio 30/70 // PROPORTIONER // ANESTHESIA MACHINE"; Printed on sticker affixed to back of machine: "Ohio 30/70 // PROPORTIONER // ANESTHETIC MACHINE // STOCK NUMBER // 216-6993-800 // SERIAL NUMBER // BCFG 00654 // Made in U.S.A. // Ohio Medical Products // A DIVISION OF AIRCO, INC. // MADISON, WISCONSIN. 53707 // AIRCO"; Printed on sticker affixed to manifold cap at the back to trolley bar: "MANIFOLD CAP: TO USE MACHINE // WHEN ONE VAPORIZER IS DETACHED // THIS CAP WITH GASKET MUST RE- // PLACE THE MISSING VAPORIZER"; Printed on sticker affixed to back of Standard Flowmeter Shiel: "NITROUS OXIDE // OXYGEN // PROPORTIONER // BCE F00709 // M.F.D. BY: // TESCOM CORPORATION // MINNEAPOLIS, MINNESOTA, 55441 // M.F.D. FOR: // Ohio Medical Products // A DIVISION OF AIRCO, INC // MADISON, WISCONSIN, 53707 // AIRCO"; Printed on sticker affixed to counter-top: "IMPORTANT: // THIS MACHINE IS EQUIPPED WITH A PRESSURE // SENSOR SYSTEM. _ OXYGEN CIRCUIT MUST BE // PRESSURIZED BEFORE OTHER GASES WILL FOLLOW."; Printed on instruction sheet hanging on the machine: "Ohio 30/70 PROPORTIONER // ANESTHESIA MACHINE // LOW PRESSURE // CIRCUIT LEAK TEST"; Printed on sticker affixed to front of machine: "HOME & HOSPITAL // SERVICES // Dial (416) 445-6479 // DATE SERVICED // FEB 12 1982"; Printed on sticker affixed to front of machine: "MINISTRY OF HEALTH // Ontario // 044715"
Permanent Location
(a-e) Storage Room W1
W1-5-1
(f-j) Storage Room 2005
2005-2-5 Box 18
Condition Remarks
Artefact in great condition; instructional manuals beginning to fade
Copy Type
Original
Reference Types
Internet
Reference Comments
Internet site "Winterlude Symposium 1994 - Troubleshooting the Anasthesia Machine", section "Troubleshooting the Anesthesia Machine